Loading…

Performance of a Small-Sized, Critical Flowmeter Assembly

Measurement of low mass-flow rates was readily accomplished by development of two similar flowmetering assemblies. Each assembly consisted of five 0.016 to 0.070-in. diameter critical-flow nozzles and individual control valves connected between common inlet and exit manifolds. Mass-flow rates throug...

Full description

Saved in:
Bibliographic Details
Published in:Journal of basic engineering 1965-12, Vol.87 (4), p.1025-1027
Main Author: Dye, D. E
Format: Article
Language:English
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Measurement of low mass-flow rates was readily accomplished by development of two similar flowmetering assemblies. Each assembly consisted of five 0.016 to 0.070-in. diameter critical-flow nozzles and individual control valves connected between common inlet and exit manifolds. Mass-flow rates through each nozzle were determined over a range of upstream pressure and temperature. The probable deviations in the measured data are approximately ≠0.83 percent. Discharge coefficients were calculated from the calibration results using the well-known one-dimensional critical-flow equation. An average error of ≠2.5 percent in the discharge coefficient is possible because of the difficulty in determining true throat areas of these small-sized nozzles.
ISSN:0098-2202
0021-9223
1528-901X
DOI:10.1115/1.3650794