Loading…

Impact of renal dysfunction on weaning from prolonged mechanical ventilation

In the intensive care unit (ICU) setting, the combination of mechanical ventilation and renal replacement therapy (RRT) has been associated with prolonged length of hospital stay, high cost of care and poor outcome. We gathered outcome data on patients who had severe renal dysfunction on transfer to...

Full description

Saved in:
Bibliographic Details
Published in:Critical care (London, England) England), 1998-01, Vol.1 (3), p.101-104, Article 101
Main Authors: Chao, David C, Scheinhorn, David J, Stearn-Hassenpflug, Meg
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83
cites cdi_FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83
container_end_page 104
container_issue 3
container_start_page 101
container_title Critical care (London, England)
container_volume 1
creator Chao, David C
Scheinhorn, David J
Stearn-Hassenpflug, Meg
description In the intensive care unit (ICU) setting, the combination of mechanical ventilation and renal replacement therapy (RRT) has been associated with prolonged length of hospital stay, high cost of care and poor outcome. We gathered outcome data on patients who had severe renal dysfunction on transfer to our regional weaning center (RWC) for attempted weaning from prolonged mechanical ventilation (PMV). We screened the admission laboratory values of 1077 patients transferred to our RWC over an 8-year period. We reviewed the medical records of patients with serum creatinine > 2.5 mg/dl. Sixty-three patients met screening criteria and 40 patients were on RRT at the time of transfer. Eighteen patients had begun chronic RRT at least 2 months prior to admission to the transferring hospital for their current illness. Twenty-two patients had RRT initiated at the transferring hospital. Ten patients had RRT initiated at the RWC; eight patients had improvement or resolution of azotemia at our facility. RRT was withheld at patient/family request in five patients with progressive renal failure. None of the 50 patients who received RRT recovered renal function during treatment at our RWC. Intermittent hemodialysis was the standard RRT at the RWC. Duration of mechanical ventilation prior to transfer to the RWC was 49.7 [+ or -] 33.5 days (mean [+ or -] SD).
doi_str_mv 10.1186/cc112
format article
fullrecord <record><control><sourceid>gale_biome</sourceid><recordid>TN_cdi_biomedcentral_primary_oai_biomedcentral_com_cc112</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><galeid>A779208184</galeid><sourcerecordid>A779208184</sourcerecordid><originalsourceid>FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83</originalsourceid><addsrcrecordid>eNpVkFtLAzEQhYMoWGv_Q0B8XM1ld5N9LEVtoeCLPodca2STlKQq_femtojCwAyc8x2GA8AMozuMeX-vNcbkDEww7duGd7Q7_3NfgqtS3hHCjPd0AtarsJV6B5OD2UY5QrMv7iPqnU8R1vmyMvq4gS6nALc5jSlurIHB6rcq6Ap82rjzozwA1-DCybHY2WlPwevjw8ti2ayfn1aL-bpRpCWkoYNRnDCNqWtl75jExhqnWIu5I05SLpm2qh6dQqzjg2M9sQa5QRuCleV0CvgxV_kUrNH1gyxHsc0-yLwXSXrxX9EpiJ9WKnpzRDdytMJHl6pBB1-0mDM2EMQxb6vr9ujSOZWSrfvNxkgcOj6lfQNrOHDC</addsrcrecordid><sourcetype>Open Access Repository</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Impact of renal dysfunction on weaning from prolonged mechanical ventilation</title><source>PubMed Central</source><creator>Chao, David C ; Scheinhorn, David J ; Stearn-Hassenpflug, Meg</creator><creatorcontrib>Chao, David C ; Scheinhorn, David J ; Stearn-Hassenpflug, Meg</creatorcontrib><description>In the intensive care unit (ICU) setting, the combination of mechanical ventilation and renal replacement therapy (RRT) has been associated with prolonged length of hospital stay, high cost of care and poor outcome. We gathered outcome data on patients who had severe renal dysfunction on transfer to our regional weaning center (RWC) for attempted weaning from prolonged mechanical ventilation (PMV). We screened the admission laboratory values of 1077 patients transferred to our RWC over an 8-year period. We reviewed the medical records of patients with serum creatinine &gt; 2.5 mg/dl. Sixty-three patients met screening criteria and 40 patients were on RRT at the time of transfer. Eighteen patients had begun chronic RRT at least 2 months prior to admission to the transferring hospital for their current illness. Twenty-two patients had RRT initiated at the transferring hospital. Ten patients had RRT initiated at the RWC; eight patients had improvement or resolution of azotemia at our facility. RRT was withheld at patient/family request in five patients with progressive renal failure. None of the 50 patients who received RRT recovered renal function during treatment at our RWC. Intermittent hemodialysis was the standard RRT at the RWC. Duration of mechanical ventilation prior to transfer to the RWC was 49.7 [+ or -] 33.5 days (mean [+ or -] SD).</description><identifier>ISSN: 1364-8535</identifier><identifier>EISSN: 1364-8535</identifier><identifier>EISSN: 1466-609X</identifier><identifier>DOI: 10.1186/cc112</identifier><language>eng</language><publisher>BioMed Central Ltd</publisher><subject>Analysis ; Care and treatment ; Complications and side effects ; Diagnosis ; Hospital patients ; Kidney diseases ; Medical care, Cost of ; Ventilator weaning</subject><ispartof>Critical care (London, England), 1998-01, Vol.1 (3), p.101-104, Article 101</ispartof><rights>COPYRIGHT 1998 BioMed Central Ltd.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83</citedby><cites>FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>230,314,776,780,881,27901,27902</link.rule.ids></links><search><creatorcontrib>Chao, David C</creatorcontrib><creatorcontrib>Scheinhorn, David J</creatorcontrib><creatorcontrib>Stearn-Hassenpflug, Meg</creatorcontrib><title>Impact of renal dysfunction on weaning from prolonged mechanical ventilation</title><title>Critical care (London, England)</title><description>In the intensive care unit (ICU) setting, the combination of mechanical ventilation and renal replacement therapy (RRT) has been associated with prolonged length of hospital stay, high cost of care and poor outcome. We gathered outcome data on patients who had severe renal dysfunction on transfer to our regional weaning center (RWC) for attempted weaning from prolonged mechanical ventilation (PMV). We screened the admission laboratory values of 1077 patients transferred to our RWC over an 8-year period. We reviewed the medical records of patients with serum creatinine &gt; 2.5 mg/dl. Sixty-three patients met screening criteria and 40 patients were on RRT at the time of transfer. Eighteen patients had begun chronic RRT at least 2 months prior to admission to the transferring hospital for their current illness. Twenty-two patients had RRT initiated at the transferring hospital. Ten patients had RRT initiated at the RWC; eight patients had improvement or resolution of azotemia at our facility. RRT was withheld at patient/family request in five patients with progressive renal failure. None of the 50 patients who received RRT recovered renal function during treatment at our RWC. Intermittent hemodialysis was the standard RRT at the RWC. Duration of mechanical ventilation prior to transfer to the RWC was 49.7 [+ or -] 33.5 days (mean [+ or -] SD).</description><subject>Analysis</subject><subject>Care and treatment</subject><subject>Complications and side effects</subject><subject>Diagnosis</subject><subject>Hospital patients</subject><subject>Kidney diseases</subject><subject>Medical care, Cost of</subject><subject>Ventilator weaning</subject><issn>1364-8535</issn><issn>1364-8535</issn><issn>1466-609X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1998</creationdate><recordtype>article</recordtype><recordid>eNpVkFtLAzEQhYMoWGv_Q0B8XM1ld5N9LEVtoeCLPodca2STlKQq_femtojCwAyc8x2GA8AMozuMeX-vNcbkDEww7duGd7Q7_3NfgqtS3hHCjPd0AtarsJV6B5OD2UY5QrMv7iPqnU8R1vmyMvq4gS6nALc5jSlurIHB6rcq6Ap82rjzozwA1-DCybHY2WlPwevjw8ti2ayfn1aL-bpRpCWkoYNRnDCNqWtl75jExhqnWIu5I05SLpm2qh6dQqzjg2M9sQa5QRuCleV0CvgxV_kUrNH1gyxHsc0-yLwXSXrxX9EpiJ9WKnpzRDdytMJHl6pBB1-0mDM2EMQxb6vr9ujSOZWSrfvNxkgcOj6lfQNrOHDC</recordid><startdate>19980122</startdate><enddate>19980122</enddate><creator>Chao, David C</creator><creator>Scheinhorn, David J</creator><creator>Stearn-Hassenpflug, Meg</creator><general>BioMed Central Ltd</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19980122</creationdate><title>Impact of renal dysfunction on weaning from prolonged mechanical ventilation</title><author>Chao, David C ; Scheinhorn, David J ; Stearn-Hassenpflug, Meg</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1998</creationdate><topic>Analysis</topic><topic>Care and treatment</topic><topic>Complications and side effects</topic><topic>Diagnosis</topic><topic>Hospital patients</topic><topic>Kidney diseases</topic><topic>Medical care, Cost of</topic><topic>Ventilator weaning</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Chao, David C</creatorcontrib><creatorcontrib>Scheinhorn, David J</creatorcontrib><creatorcontrib>Stearn-Hassenpflug, Meg</creatorcontrib><collection>CrossRef</collection><jtitle>Critical care (London, England)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Chao, David C</au><au>Scheinhorn, David J</au><au>Stearn-Hassenpflug, Meg</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Impact of renal dysfunction on weaning from prolonged mechanical ventilation</atitle><jtitle>Critical care (London, England)</jtitle><date>1998-01-22</date><risdate>1998</risdate><volume>1</volume><issue>3</issue><spage>101</spage><epage>104</epage><pages>101-104</pages><artnum>101</artnum><issn>1364-8535</issn><eissn>1364-8535</eissn><eissn>1466-609X</eissn><abstract>In the intensive care unit (ICU) setting, the combination of mechanical ventilation and renal replacement therapy (RRT) has been associated with prolonged length of hospital stay, high cost of care and poor outcome. We gathered outcome data on patients who had severe renal dysfunction on transfer to our regional weaning center (RWC) for attempted weaning from prolonged mechanical ventilation (PMV). We screened the admission laboratory values of 1077 patients transferred to our RWC over an 8-year period. We reviewed the medical records of patients with serum creatinine &gt; 2.5 mg/dl. Sixty-three patients met screening criteria and 40 patients were on RRT at the time of transfer. Eighteen patients had begun chronic RRT at least 2 months prior to admission to the transferring hospital for their current illness. Twenty-two patients had RRT initiated at the transferring hospital. Ten patients had RRT initiated at the RWC; eight patients had improvement or resolution of azotemia at our facility. RRT was withheld at patient/family request in five patients with progressive renal failure. None of the 50 patients who received RRT recovered renal function during treatment at our RWC. Intermittent hemodialysis was the standard RRT at the RWC. Duration of mechanical ventilation prior to transfer to the RWC was 49.7 [+ or -] 33.5 days (mean [+ or -] SD).</abstract><pub>BioMed Central Ltd</pub><doi>10.1186/cc112</doi><tpages>4</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1364-8535
ispartof Critical care (London, England), 1998-01, Vol.1 (3), p.101-104, Article 101
issn 1364-8535
1364-8535
1466-609X
language eng
recordid cdi_biomedcentral_primary_oai_biomedcentral_com_cc112
source PubMed Central
subjects Analysis
Care and treatment
Complications and side effects
Diagnosis
Hospital patients
Kidney diseases
Medical care, Cost of
Ventilator weaning
title Impact of renal dysfunction on weaning from prolonged mechanical ventilation
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-08T03%3A26%3A31IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-gale_biome&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Impact%20of%20renal%20dysfunction%20on%20weaning%20from%20prolonged%20mechanical%20ventilation&rft.jtitle=Critical%20care%20(London,%20England)&rft.au=Chao,%20David%20C&rft.date=1998-01-22&rft.volume=1&rft.issue=3&rft.spage=101&rft.epage=104&rft.pages=101-104&rft.artnum=101&rft.issn=1364-8535&rft.eissn=1364-8535&rft_id=info:doi/10.1186/cc112&rft_dat=%3Cgale_biome%3EA779208184%3C/gale_biome%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-b2422-39db827c13f4a6f7a1dedfb7418f2fa38a7cebfa35b07589f762ed0f9cd21be83%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_galeid=A779208184&rfr_iscdi=true