Investigation of the lateral spread of erbium ions implanted in silicon crystal
The erbium ions at energy of 400 keV and dose of 5× 10^15 ions/cm^2 were implanted into silicon single crystals at room temperature at the angles of 0°,45° and 60°. The lateral spread of 400 keV erbium ions implanted in silicon sample was measured by the Rutherford backscattering technique. The resu...
Saved in:
Published in: | Chinese physics B 2010-11, Vol.19 (11), p.336-339, Article 113403 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The erbium ions at energy of 400 keV and dose of 5× 10^15 ions/cm^2 were implanted into silicon single crystals at room temperature at the angles of 0°,45° and 60°. The lateral spread of 400 keV erbium ions implanted in silicon sample was measured by the Rutherford backscattering technique. The results show that the measured values were in good agreement with those obtained from the prediction of TRIM'98 (Transport of Ions in Matter) and SRIM2006 (Stopping and Range of Ions in Matter) codes. |
---|---|
ISSN: | 1674-1056 2058-3834 |