Loading…
Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation
A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid...
Saved in:
Published in: | 中国物理C:英文版 2014 (5), p.62-68 |
---|---|
Main Author: | |
Format: | Article |
Language: | English |
Subjects: | |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | |
---|---|
cites | |
container_end_page | 68 |
container_issue | 5 |
container_start_page | 62 |
container_title | 中国物理C:英文版 |
container_volume | |
creator | Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed |
description | A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid. |
format | article |
fullrecord | <record><control><sourceid>chongqing</sourceid><recordid>TN_cdi_chongqing_primary_49481342</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><cqvip_id>49481342</cqvip_id><sourcerecordid>49481342</sourcerecordid><originalsourceid>FETCH-chongqing_primary_494813423</originalsourceid><addsrcrecordid>eNqNjM2KwjAUhYMoWH_e4c4DFJImal3LOOPCnXtJm1uNpLmaH6FvPx2YBxg4cBbn-86EFbzaqFLyTTVlhdjuVCmE3M3ZIsYH51vF67pg-eQ7l9G3CNRBug-BrIE3udwjBDS5TZY8jNFNpNCgAUMRwXoQUpxGA4N-DhBTNnYcmwFytP4GX6h9UnAmnxAOOjiCaPvs9O_fis067SKu_3rJPo6fl8N32d7J316jf30G2-swXNVe1UKqSv6H-QEZtUwc</addsrcrecordid><sourcetype>Publisher</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation</title><source>Institute of Physics</source><creator>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</creator><creatorcontrib>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</creatorcontrib><description>A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.</description><identifier>ISSN: 1674-1137</identifier><identifier>EISSN: 0254-3052</identifier><language>eng</language><subject>Geant4 ; MCNP ; 体积 ; 吸收剂量 ; 放射治疗 ; 模拟 ; 甲状腺 ; 蒙特卡罗模型</subject><ispartof>中国物理C:英文版, 2014 (5), p.62-68</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Uhttp://image.cqvip.com/vip1000/qk/92043A/92043A.jpg</thumbnail><link.rule.ids>314,776,780,4009</link.rule.ids></links><search><creatorcontrib>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</creatorcontrib><title>Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation</title><title>中国物理C:英文版</title><addtitle>Chinese Physica C</addtitle><description>A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.</description><subject>Geant4</subject><subject>MCNP</subject><subject>体积</subject><subject>吸收剂量</subject><subject>放射治疗</subject><subject>模拟</subject><subject>甲状腺</subject><subject>蒙特卡罗模型</subject><issn>1674-1137</issn><issn>0254-3052</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2014</creationdate><recordtype>article</recordtype><recordid>eNqNjM2KwjAUhYMoWH_e4c4DFJImal3LOOPCnXtJm1uNpLmaH6FvPx2YBxg4cBbn-86EFbzaqFLyTTVlhdjuVCmE3M3ZIsYH51vF67pg-eQ7l9G3CNRBug-BrIE3udwjBDS5TZY8jNFNpNCgAUMRwXoQUpxGA4N-DhBTNnYcmwFytP4GX6h9UnAmnxAOOjiCaPvs9O_fis067SKu_3rJPo6fl8N32d7J316jf30G2-swXNVe1UKqSv6H-QEZtUwc</recordid><startdate>2014</startdate><enddate>2014</enddate><creator>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</creator><scope>2RA</scope><scope>92L</scope><scope>CQIGP</scope><scope>~WA</scope></search><sort><creationdate>2014</creationdate><title>Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation</title><author>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-chongqing_primary_494813423</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2014</creationdate><topic>Geant4</topic><topic>MCNP</topic><topic>体积</topic><topic>吸收剂量</topic><topic>放射治疗</topic><topic>模拟</topic><topic>甲状腺</topic><topic>蒙特卡罗模型</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</creatorcontrib><collection>维普_期刊</collection><collection>中文科技期刊数据库-CALIS站点</collection><collection>中文科技期刊数据库-7.0平台</collection><collection>中文科技期刊数据库- 镜像站点</collection><jtitle>中国物理C:英文版</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Ziaur Rahman Sikander M Mirza Waheed Arshed Nasir M Mirza Waheed Ahmed</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation</atitle><jtitle>中国物理C:英文版</jtitle><addtitle>Chinese Physica C</addtitle><date>2014</date><risdate>2014</risdate><issue>5</issue><spage>62</spage><epage>68</epage><pages>62-68</pages><issn>1674-1137</issn><eissn>0254-3052</eissn><abstract>A simulation study has been performed to quantify the effect of volume reduction on the thyroid absorbed dose per decay and to investigate the variation of energy deposition per decay due to β- and γ-activity of 131I with volume/mass of thyroid, for water, ICRP- and ICRU-soft tissue taken as thyroid material. A Monte Carlo model of the thyroid, in the Geant4 radiation transport simulation toolkit was constructed to compute the β- and γ-absorbed dose in the simulated thyroid phantom for various values of its volume. The effect of the size and shape of the thyroid on energy deposition per decay has also been studied by using spherical, ellipsoidal and cylindrical models for the thyroid and varying its volume in 1-25 cm3 range. The relative differences of Geant4 results for different models with each other and MCNP results lie well below 1.870%. The maximum relative difference among the Geant4 estimated results for water with ICRP and ICRU soft tissues is not more than 0.225%. S-values for ellipsoidal, spherical and cylindrical thyroid models were estimated and the relative difference with published results lies within 3.095%. The absorbed fraction values for beta particles show a good agreement with published values within 2.105% deviation. The Geant4 based simulation results of absorbed fractions for gammas again show a good agreement with the corresponding MCNP and EGS4 results (±6.667%) but have 29.032% higher values than that of MIRD calculated values. Consistent with previous studies, the reduction of the thyroid volume is found to have a substantial effect on the absorbed dose. Geant4 simulations confirm dose dependence on the volume/mass of thyroid in agreement with MCNP and EGS4 computed values but are substantially different from MIRD8 data. Therefore, inclusion of size/mass dependence is indicated for 131I radiotherapy of the thyroid.</abstract></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1674-1137 |
ispartof | 中国物理C:英文版, 2014 (5), p.62-68 |
issn | 1674-1137 0254-3052 |
language | eng |
recordid | cdi_chongqing_primary_49481342 |
source | Institute of Physics |
subjects | Geant4 MCNP 体积 吸收剂量 放射治疗 模拟 甲状腺 蒙特卡罗模型 |
title | Influence of thyroid volume reduction on absorbed dose in 131I therapy studied by using Geant4 Monte Carlo simulation |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-22T19%3A05%3A02IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-chongqing&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Influence%20of%20thyroid%20volume%20reduction%20on%20absorbed%20dose%20in%20131I%20therapy%20studied%20by%20using%20Geant4%20Monte%20Carlo%20simulation&rft.jtitle=%E4%B8%AD%E5%9B%BD%E7%89%A9%E7%90%86C%EF%BC%9A%E8%8B%B1%E6%96%87%E7%89%88&rft.au=Ziaur%20Rahman%20Sikander%20M%20Mirza%20Waheed%20Arshed%20Nasir%20M%20Mirza%20Waheed%20Ahmed&rft.date=2014&rft.issue=5&rft.spage=62&rft.epage=68&rft.pages=62-68&rft.issn=1674-1137&rft.eissn=0254-3052&rft_id=info:doi/&rft_dat=%3Cchongqing%3E49481342%3C/chongqing%3E%3Cgrp_id%3Ecdi_FETCH-chongqing_primary_494813423%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rft_cqvip_id=49481342&rfr_iscdi=true |