Loading…

Research of Final EMS for Bloom in Ansteel

In this paper,the best final EMS frequency for bloom continuous casting is proposed.For 280×380 bloom,the best frequency is in the range of 4~7 Hz.Simulation results also show that,with this frequency,the electromagnetic force in the molten steel in the bloom reaches stronger and the electromechanic...

Full description

Saved in:
Bibliographic Details
Published in:钢铁研究学报:英文版 2012 (S2), p.892-895
Main Author: GUO Qing-tao JIN Bai-gang LUO Jian-hua NI Chong-yi WAN Xue-feng LIAO Xiang-wei
Format: Article
Language:English
Subjects:
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:In this paper,the best final EMS frequency for bloom continuous casting is proposed.For 280×380 bloom,the best frequency is in the range of 4~7 Hz.Simulation results also show that,with this frequency,the electromagnetic force in the molten steel in the bloom reaches stronger and the electromechanical transformation rate of the stirring equipment is higher.The flow fields in the bloom with the various stirring parameters are simulated also.The final EMS parameters for bloom are optimized base on the simulation results.The experimental results show that,for high carbon steel,the best stirring frequency is 7 Hz and the current is 500A.In order to alleviate negative segregation of the low and medium carbon steel,the stirring frequency and the current should be 4Hz and 430A,respectively.
ISSN:1006-706X