Temperature profiles were measured in a spray‐column heat exchanger 7.5 cm. in diameter and 167 cm. long between the inlets of warm kerosene and cold water. The temperature jump, at the inlet of the continuous phase, is a measure of the amount of mixing in the column and is a function of holdup and...

Full description

Saved in:
Bibliographic Details
Published in:AIChE journal 1965-09, Vol.11 (5), p.804-808
Main Authors: Letan, Ruth, Kehat, Ephraim
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Temperature profiles were measured in a spray‐column heat exchanger 7.5 cm. in diameter and 167 cm. long between the inlets of warm kerosene and cold water. The temperature jump, at the inlet of the continuous phase, is a measure of the amount of mixing in the column and is a function of holdup and ratio of flow rates of the two phases. At holdup the temperature jump had a minimum value of 0.24. A physical model for heat transfer in a spray column based on hydrodynamic principles is proposed. Heat is transferred from drop to wake downstream of drop. Wakes are shed and mixed with the bulk water flow. New material enters the wake and is spilled out at higher temperatures. The physical model is applied to explain the data on temperature jumps in spray‐column heat exchangers and the data on concentration jumps in spray‐column extractors.