Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination
This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied fo...
Saved in:
Published in: | Electroanalysis (New York, N.Y.) N.Y.), 2005-11, Vol.17 (22), p.2084-2089 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43 |
---|---|
cites | cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43 |
container_end_page | 2089 |
container_issue | 22 |
container_start_page | 2084 |
container_title | Electroanalysis (New York, N.Y.) |
container_volume | 17 |
creator | Gonzaga, Fabiano Barbieri Pereira, Claudete Fernandes Guaritá-Santos, Antonio José Moraes Souza De, Jurandir Rodrigues |
description | This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%. |
doi_str_mv | 10.1002/elan.200503338 |
format | article |
fullrecord | <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_200503338</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ELAN200503338</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</originalsourceid><addsrcrecordid>eNqFkMtLAzEQhxdRUKtXzznqYesk2VeOS1u1UFbF1zHEdILRfZGNj179y42tiDfJQIaZ-X6HL4qOKIwpADvFWrVjBpAC57zYivZoymicUBDboYcEYuAi3432h-EZAESWiL3oc4pvWHd9g60nnSGqJeWr7xrlrSazGrV3nX7CxmpVk5vV4LEhpnNkao1BFyAb5lev9YCkbHp0XYPerULMksz9QMq-rwPqbdeusRs8nt-fkCl6dI1t14uDaMeoEHD484-iu7PZ7eQiXlyezyflItac5UWcmizRGRVLUDnHVFAwTCFbclYIRjOWifDoIw9lAAtTgGZLrbRSmAmuEj6Kxptc7bphcGhk72yj3EpSkN8G5bdB-WswAGIDvNsaV_9cy9mirP6y8Ya1QdnHL6vci8xynqfyoTqXkOZVNbmo5DX_AhYYhiw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><source>Wiley-Blackwell Read & Publish Collection</source><creator>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</creator><creatorcontrib>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</creatorcontrib><description>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.200503338</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Data acquisition ; Differential pulse amperometry ; Gold electrode ; Instrumentation ; Selenium determination</subject><ispartof>Electroanalysis (New York, N.Y.), 2005-11, Vol.17 (22), p.2084-2089</ispartof><rights>Copyright © 2005 WILEY‐VCH Verlag GmbH & Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</citedby><cites>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gonzaga, Fabiano Barbieri</creatorcontrib><creatorcontrib>Pereira, Claudete Fernandes</creatorcontrib><creatorcontrib>Guaritá-Santos, Antonio José Moraes</creatorcontrib><creatorcontrib>Souza De, Jurandir Rodrigues</creatorcontrib><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</description><subject>Data acquisition</subject><subject>Differential pulse amperometry</subject><subject>Gold electrode</subject><subject>Instrumentation</subject><subject>Selenium determination</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkMtLAzEQhxdRUKtXzznqYesk2VeOS1u1UFbF1zHEdILRfZGNj179y42tiDfJQIaZ-X6HL4qOKIwpADvFWrVjBpAC57zYivZoymicUBDboYcEYuAi3432h-EZAESWiL3oc4pvWHd9g60nnSGqJeWr7xrlrSazGrV3nX7CxmpVk5vV4LEhpnNkao1BFyAb5lev9YCkbHp0XYPerULMksz9QMq-rwPqbdeusRs8nt-fkCl6dI1t14uDaMeoEHD484-iu7PZ7eQiXlyezyflItac5UWcmizRGRVLUDnHVFAwTCFbclYIRjOWifDoIw9lAAtTgGZLrbRSmAmuEj6Kxptc7bphcGhk72yj3EpSkN8G5bdB-WswAGIDvNsaV_9cy9mirP6y8Ya1QdnHL6vci8xynqfyoTqXkOZVNbmo5DX_AhYYhiw</recordid><startdate>200511</startdate><enddate>200511</enddate><creator>Gonzaga, Fabiano Barbieri</creator><creator>Pereira, Claudete Fernandes</creator><creator>Guaritá-Santos, Antonio José Moraes</creator><creator>Souza De, Jurandir Rodrigues</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200511</creationdate><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><author>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Data acquisition</topic><topic>Differential pulse amperometry</topic><topic>Gold electrode</topic><topic>Instrumentation</topic><topic>Selenium determination</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gonzaga, Fabiano Barbieri</creatorcontrib><creatorcontrib>Pereira, Claudete Fernandes</creatorcontrib><creatorcontrib>Guaritá-Santos, Antonio José Moraes</creatorcontrib><creatorcontrib>Souza De, Jurandir Rodrigues</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gonzaga, Fabiano Barbieri</au><au>Pereira, Claudete Fernandes</au><au>Guaritá-Santos, Antonio José Moraes</au><au>Souza De, Jurandir Rodrigues</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2005-11</date><risdate>2005</risdate><volume>17</volume><issue>22</issue><spage>2084</spage><epage>2089</epage><pages>2084-2089</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.200503338</doi><tpages>6</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1040-0397 |
ispartof | Electroanalysis (New York, N.Y.), 2005-11, Vol.17 (22), p.2084-2089 |
issn | 1040-0397 1521-4109 |
language | eng |
recordid | cdi_crossref_primary_10_1002_elan_200503338 |
source | Wiley-Blackwell Read & Publish Collection |
subjects | Data acquisition Differential pulse amperometry Gold electrode Instrumentation Selenium determination |
title | Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T03%3A11%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20an%20Automatic%20Electrochemical%20System%20for%20Differential%20Pulse%20Amperometry%20and%20Its%20Application%20for%20Se(IV)%20Determination&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Gonzaga,%20Fabiano%E2%80%85Barbieri&rft.date=2005-11&rft.volume=17&rft.issue=22&rft.spage=2084&rft.epage=2089&rft.pages=2084-2089&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.200503338&rft_dat=%3Cwiley_cross%3EELAN200503338%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |