Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination

This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied fo...

Full description

Saved in:
Bibliographic Details
Published in:Electroanalysis (New York, N.Y.) N.Y.), 2005-11, Vol.17 (22), p.2084-2089
Main Authors: Gonzaga, Fabiano Barbieri, Pereira, Claudete Fernandes, Guaritá-Santos, Antonio José Moraes, Souza De, Jurandir Rodrigues
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43
cites cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43
container_end_page 2089
container_issue 22
container_start_page 2084
container_title Electroanalysis (New York, N.Y.)
container_volume 17
creator Gonzaga, Fabiano Barbieri
Pereira, Claudete Fernandes
Guaritá-Santos, Antonio José Moraes
Souza De, Jurandir Rodrigues
description This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.
doi_str_mv 10.1002/elan.200503338
format article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_elan_200503338</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>ELAN200503338</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</originalsourceid><addsrcrecordid>eNqFkMtLAzEQhxdRUKtXzznqYesk2VeOS1u1UFbF1zHEdILRfZGNj179y42tiDfJQIaZ-X6HL4qOKIwpADvFWrVjBpAC57zYivZoymicUBDboYcEYuAi3432h-EZAESWiL3oc4pvWHd9g60nnSGqJeWr7xrlrSazGrV3nX7CxmpVk5vV4LEhpnNkao1BFyAb5lev9YCkbHp0XYPerULMksz9QMq-rwPqbdeusRs8nt-fkCl6dI1t14uDaMeoEHD484-iu7PZ7eQiXlyezyflItac5UWcmizRGRVLUDnHVFAwTCFbclYIRjOWifDoIw9lAAtTgGZLrbRSmAmuEj6Kxptc7bphcGhk72yj3EpSkN8G5bdB-WswAGIDvNsaV_9cy9mirP6y8Ya1QdnHL6vci8xynqfyoTqXkOZVNbmo5DX_AhYYhiw</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</creator><creatorcontrib>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</creatorcontrib><description>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</description><identifier>ISSN: 1040-0397</identifier><identifier>EISSN: 1521-4109</identifier><identifier>DOI: 10.1002/elan.200503338</identifier><language>eng</language><publisher>Weinheim: WILEY-VCH Verlag</publisher><subject>Data acquisition ; Differential pulse amperometry ; Gold electrode ; Instrumentation ; Selenium determination</subject><ispartof>Electroanalysis (New York, N.Y.), 2005-11, Vol.17 (22), p.2084-2089</ispartof><rights>Copyright © 2005 WILEY‐VCH Verlag GmbH &amp; Co. KGaA, Weinheim</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</citedby><cites>FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Gonzaga, Fabiano Barbieri</creatorcontrib><creatorcontrib>Pereira, Claudete Fernandes</creatorcontrib><creatorcontrib>Guaritá-Santos, Antonio José Moraes</creatorcontrib><creatorcontrib>Souza De, Jurandir Rodrigues</creatorcontrib><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><title>Electroanalysis (New York, N.Y.)</title><addtitle>Electroanalysis</addtitle><description>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</description><subject>Data acquisition</subject><subject>Differential pulse amperometry</subject><subject>Gold electrode</subject><subject>Instrumentation</subject><subject>Selenium determination</subject><issn>1040-0397</issn><issn>1521-4109</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2005</creationdate><recordtype>article</recordtype><recordid>eNqFkMtLAzEQhxdRUKtXzznqYesk2VeOS1u1UFbF1zHEdILRfZGNj179y42tiDfJQIaZ-X6HL4qOKIwpADvFWrVjBpAC57zYivZoymicUBDboYcEYuAi3432h-EZAESWiL3oc4pvWHd9g60nnSGqJeWr7xrlrSazGrV3nX7CxmpVk5vV4LEhpnNkao1BFyAb5lev9YCkbHp0XYPerULMksz9QMq-rwPqbdeusRs8nt-fkCl6dI1t14uDaMeoEHD484-iu7PZ7eQiXlyezyflItac5UWcmizRGRVLUDnHVFAwTCFbclYIRjOWifDoIw9lAAtTgGZLrbRSmAmuEj6Kxptc7bphcGhk72yj3EpSkN8G5bdB-WswAGIDvNsaV_9cy9mirP6y8Ya1QdnHL6vci8xynqfyoTqXkOZVNbmo5DX_AhYYhiw</recordid><startdate>200511</startdate><enddate>200511</enddate><creator>Gonzaga, Fabiano Barbieri</creator><creator>Pereira, Claudete Fernandes</creator><creator>Guaritá-Santos, Antonio José Moraes</creator><creator>Souza De, Jurandir Rodrigues</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200511</creationdate><title>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</title><author>Gonzaga, Fabiano Barbieri ; Pereira, Claudete Fernandes ; Guaritá-Santos, Antonio José Moraes ; Souza De, Jurandir Rodrigues</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2005</creationdate><topic>Data acquisition</topic><topic>Differential pulse amperometry</topic><topic>Gold electrode</topic><topic>Instrumentation</topic><topic>Selenium determination</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Gonzaga, Fabiano Barbieri</creatorcontrib><creatorcontrib>Pereira, Claudete Fernandes</creatorcontrib><creatorcontrib>Guaritá-Santos, Antonio José Moraes</creatorcontrib><creatorcontrib>Souza De, Jurandir Rodrigues</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Electroanalysis (New York, N.Y.)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Gonzaga, Fabiano Barbieri</au><au>Pereira, Claudete Fernandes</au><au>Guaritá-Santos, Antonio José Moraes</au><au>Souza De, Jurandir Rodrigues</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination</atitle><jtitle>Electroanalysis (New York, N.Y.)</jtitle><addtitle>Electroanalysis</addtitle><date>2005-11</date><risdate>2005</risdate><volume>17</volume><issue>22</issue><spage>2084</spage><epage>2089</epage><pages>2084-2089</pages><issn>1040-0397</issn><eissn>1521-4109</eissn><abstract>This work presents the development of an automatic system for differential pulse amperometry (DPA) with electrochemical deposition. The system consists of a microcomputer, running a home‐made software, connected to a commercial potentiostat through a data acquisition board. The system was applied for selenium determination using gold electrode and flow injection analysis (FIA). Analytical curves were obtained in the concentration range of 20 to 400 μg L−1 for Se(IV), with a calculated detection limit of 6 μg L−1. The analysis results for fish samples doped with Se(IV) and digested in a microwave oven showed recoveries above 93%.</abstract><cop>Weinheim</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/elan.200503338</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1040-0397
ispartof Electroanalysis (New York, N.Y.), 2005-11, Vol.17 (22), p.2084-2089
issn 1040-0397
1521-4109
language eng
recordid cdi_crossref_primary_10_1002_elan_200503338
source Wiley-Blackwell Read & Publish Collection
subjects Data acquisition
Differential pulse amperometry
Gold electrode
Instrumentation
Selenium determination
title Development of an Automatic Electrochemical System for Differential Pulse Amperometry and Its Application for Se(IV) Determination
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T03%3A11%3A57IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Development%20of%20an%20Automatic%20Electrochemical%20System%20for%20Differential%20Pulse%20Amperometry%20and%20Its%20Application%20for%20Se(IV)%20Determination&rft.jtitle=Electroanalysis%20(New%20York,%20N.Y.)&rft.au=Gonzaga,%20Fabiano%E2%80%85Barbieri&rft.date=2005-11&rft.volume=17&rft.issue=22&rft.spage=2084&rft.epage=2089&rft.pages=2084-2089&rft.issn=1040-0397&rft.eissn=1521-4109&rft_id=info:doi/10.1002/elan.200503338&rft_dat=%3Cwiley_cross%3EELAN200503338%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3278-5f64c619d0a73e5910f2ae2d32892162696961b31b3f0e8f80c2dcacaae693a43%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true