Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach

Ground‐coupled heat exchangers (GCHE) have received significant attention over several decades as a result of increasing the world's energy demand and the need for reducing fossil fuels consumption. Prior studies have demonstrated the effectiveness of utilizing GCHE with refrigeration and heati...

Full description

Saved in:
Bibliographic Details
Published in:Heat transfer (Hoboken, N.J. Print) N.J. Print), 2024-05, Vol.53 (3), p.1474-1500
Main Authors: Kahwaji, Ghalib Y., Capuano, Davide, Boudekji, Giada, Samaha, Mohamed A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c2296-ac9bdc14707784ff9ee924007984bf391b1c2b67921aa4ea7a969e81f9501d703
container_end_page 1500
container_issue 3
container_start_page 1474
container_title Heat transfer (Hoboken, N.J. Print)
container_volume 53
creator Kahwaji, Ghalib Y.
Capuano, Davide
Boudekji, Giada
Samaha, Mohamed A.
description Ground‐coupled heat exchangers (GCHE) have received significant attention over several decades as a result of increasing the world's energy demand and the need for reducing fossil fuels consumption. Prior studies have demonstrated the effectiveness of utilizing GCHE with refrigeration and heating systems. However, optimizing the performance of GCHE coupled with chillers for heat rejection, especially in extreme hot‐humid climates (where cooling towers are not very effective) is lacking in the literature. In this work, a ground borehole fitted with a coaxial‐tubes heat exchanger (BHE) is numerically simulated. Based on a wide range of data collected for the soil of Dubai, its real in situ thermophysical properties are characterized. The soil's upper layer thickness is relatively small and dry that operates in conduction mode, while the lower one is water‐saturated that works in coupled conduction‐advection mode. The study aims at optimizing the parameters advancing heat rejection into ground considering the actual properties of the soil of Dubai. The results indicate that the more feasible high‐density polyethylene pipes can perform as good as the steel ones. Also, a great finding based on the presented novel design is that insulating the inner pipe can increase the temperature duty by 55%. The proposed design of BHE is relatively inexpensive, more feasible and efficient, which is achieved for the first time based on a deep analysis of Dubai climate and soil. This makes the technology ready to be implemented for industrial applications in Dubai and other regions having a similar climate and soil nature.
doi_str_mv 10.1002/htj.23006
format article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_htj_23006</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>HTJ23006</sourcerecordid><originalsourceid>FETCH-LOGICAL-c2296-ac9bdc14707784ff9ee924007984bf391b1c2b67921aa4ea7a969e81f9501d703</originalsourceid><addsrcrecordid>eNp1kLFOwzAQhi0EElXpwBt4ZUhrO24cs6EWWlAFS5mji3NpXKVx5CSCMvEIPCNPQiCIjelOp-9-_foIueRsyhkTs6LdT0XIWHRCRiKK40DOpTj920N5TiZNs2c9O-dciWhEcImN3VUUqoy6urUH-watdRV1Od1511XZ5_uHcV1dYkY95t7u0A9EgdBSfDUFVP2N2oouuxTsNX3sDuitgZJCXXsHprggZzmUDU5-55g8391uF-tg87S6X9xsAiOEjgIwOs0Ml4opFcs814haSMaUjmWah5qn3Ig0UlpwAImgQEcaY57rOeOZYuGYXA25xrum6esmtbcH8MeEs-RbUdIrSn4U9exsYF9sicf_wWS9fRg-vgDTq2oR</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach</title><source>Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)</source><creator>Kahwaji, Ghalib Y. ; Capuano, Davide ; Boudekji, Giada ; Samaha, Mohamed A.</creator><creatorcontrib>Kahwaji, Ghalib Y. ; Capuano, Davide ; Boudekji, Giada ; Samaha, Mohamed A.</creatorcontrib><description>Ground‐coupled heat exchangers (GCHE) have received significant attention over several decades as a result of increasing the world's energy demand and the need for reducing fossil fuels consumption. Prior studies have demonstrated the effectiveness of utilizing GCHE with refrigeration and heating systems. However, optimizing the performance of GCHE coupled with chillers for heat rejection, especially in extreme hot‐humid climates (where cooling towers are not very effective) is lacking in the literature. In this work, a ground borehole fitted with a coaxial‐tubes heat exchanger (BHE) is numerically simulated. Based on a wide range of data collected for the soil of Dubai, its real in situ thermophysical properties are characterized. The soil's upper layer thickness is relatively small and dry that operates in conduction mode, while the lower one is water‐saturated that works in coupled conduction‐advection mode. The study aims at optimizing the parameters advancing heat rejection into ground considering the actual properties of the soil of Dubai. The results indicate that the more feasible high‐density polyethylene pipes can perform as good as the steel ones. Also, a great finding based on the presented novel design is that insulating the inner pipe can increase the temperature duty by 55%. The proposed design of BHE is relatively inexpensive, more feasible and efficient, which is achieved for the first time based on a deep analysis of Dubai climate and soil. This makes the technology ready to be implemented for industrial applications in Dubai and other regions having a similar climate and soil nature.</description><identifier>ISSN: 2688-4534</identifier><identifier>EISSN: 2688-4542</identifier><identifier>DOI: 10.1002/htj.23006</identifier><language>eng</language><subject>boundary layer ; buoyancy‐driven flow ; coaxial borehole heat exchanger ; geothermal energy ; natural convection ; soil porous media</subject><ispartof>Heat transfer (Hoboken, N.J. Print), 2024-05, Vol.53 (3), p.1474-1500</ispartof><rights>2024 Wiley Periodicals LLC.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c2296-ac9bdc14707784ff9ee924007984bf391b1c2b67921aa4ea7a969e81f9501d703</cites><orcidid>0000-0001-5050-5187</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids></links><search><creatorcontrib>Kahwaji, Ghalib Y.</creatorcontrib><creatorcontrib>Capuano, Davide</creatorcontrib><creatorcontrib>Boudekji, Giada</creatorcontrib><creatorcontrib>Samaha, Mohamed A.</creatorcontrib><title>Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach</title><title>Heat transfer (Hoboken, N.J. Print)</title><description>Ground‐coupled heat exchangers (GCHE) have received significant attention over several decades as a result of increasing the world's energy demand and the need for reducing fossil fuels consumption. Prior studies have demonstrated the effectiveness of utilizing GCHE with refrigeration and heating systems. However, optimizing the performance of GCHE coupled with chillers for heat rejection, especially in extreme hot‐humid climates (where cooling towers are not very effective) is lacking in the literature. In this work, a ground borehole fitted with a coaxial‐tubes heat exchanger (BHE) is numerically simulated. Based on a wide range of data collected for the soil of Dubai, its real in situ thermophysical properties are characterized. The soil's upper layer thickness is relatively small and dry that operates in conduction mode, while the lower one is water‐saturated that works in coupled conduction‐advection mode. The study aims at optimizing the parameters advancing heat rejection into ground considering the actual properties of the soil of Dubai. The results indicate that the more feasible high‐density polyethylene pipes can perform as good as the steel ones. Also, a great finding based on the presented novel design is that insulating the inner pipe can increase the temperature duty by 55%. The proposed design of BHE is relatively inexpensive, more feasible and efficient, which is achieved for the first time based on a deep analysis of Dubai climate and soil. This makes the technology ready to be implemented for industrial applications in Dubai and other regions having a similar climate and soil nature.</description><subject>boundary layer</subject><subject>buoyancy‐driven flow</subject><subject>coaxial borehole heat exchanger</subject><subject>geothermal energy</subject><subject>natural convection</subject><subject>soil porous media</subject><issn>2688-4534</issn><issn>2688-4542</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2024</creationdate><recordtype>article</recordtype><recordid>eNp1kLFOwzAQhi0EElXpwBt4ZUhrO24cs6EWWlAFS5mji3NpXKVx5CSCMvEIPCNPQiCIjelOp-9-_foIueRsyhkTs6LdT0XIWHRCRiKK40DOpTj920N5TiZNs2c9O-dciWhEcImN3VUUqoy6urUH-watdRV1Od1511XZ5_uHcV1dYkY95t7u0A9EgdBSfDUFVP2N2oouuxTsNX3sDuitgZJCXXsHprggZzmUDU5-55g8391uF-tg87S6X9xsAiOEjgIwOs0Ml4opFcs814haSMaUjmWah5qn3Ig0UlpwAImgQEcaY57rOeOZYuGYXA25xrum6esmtbcH8MeEs-RbUdIrSn4U9exsYF9sicf_wWS9fRg-vgDTq2oR</recordid><startdate>202405</startdate><enddate>202405</enddate><creator>Kahwaji, Ghalib Y.</creator><creator>Capuano, Davide</creator><creator>Boudekji, Giada</creator><creator>Samaha, Mohamed A.</creator><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-5050-5187</orcidid></search><sort><creationdate>202405</creationdate><title>Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach</title><author>Kahwaji, Ghalib Y. ; Capuano, Davide ; Boudekji, Giada ; Samaha, Mohamed A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c2296-ac9bdc14707784ff9ee924007984bf391b1c2b67921aa4ea7a969e81f9501d703</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2024</creationdate><topic>boundary layer</topic><topic>buoyancy‐driven flow</topic><topic>coaxial borehole heat exchanger</topic><topic>geothermal energy</topic><topic>natural convection</topic><topic>soil porous media</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kahwaji, Ghalib Y.</creatorcontrib><creatorcontrib>Capuano, Davide</creatorcontrib><creatorcontrib>Boudekji, Giada</creatorcontrib><creatorcontrib>Samaha, Mohamed A.</creatorcontrib><collection>CrossRef</collection><jtitle>Heat transfer (Hoboken, N.J. Print)</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kahwaji, Ghalib Y.</au><au>Capuano, Davide</au><au>Boudekji, Giada</au><au>Samaha, Mohamed A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach</atitle><jtitle>Heat transfer (Hoboken, N.J. Print)</jtitle><date>2024-05</date><risdate>2024</risdate><volume>53</volume><issue>3</issue><spage>1474</spage><epage>1500</epage><pages>1474-1500</pages><issn>2688-4534</issn><eissn>2688-4542</eissn><abstract>Ground‐coupled heat exchangers (GCHE) have received significant attention over several decades as a result of increasing the world's energy demand and the need for reducing fossil fuels consumption. Prior studies have demonstrated the effectiveness of utilizing GCHE with refrigeration and heating systems. However, optimizing the performance of GCHE coupled with chillers for heat rejection, especially in extreme hot‐humid climates (where cooling towers are not very effective) is lacking in the literature. In this work, a ground borehole fitted with a coaxial‐tubes heat exchanger (BHE) is numerically simulated. Based on a wide range of data collected for the soil of Dubai, its real in situ thermophysical properties are characterized. The soil's upper layer thickness is relatively small and dry that operates in conduction mode, while the lower one is water‐saturated that works in coupled conduction‐advection mode. The study aims at optimizing the parameters advancing heat rejection into ground considering the actual properties of the soil of Dubai. The results indicate that the more feasible high‐density polyethylene pipes can perform as good as the steel ones. Also, a great finding based on the presented novel design is that insulating the inner pipe can increase the temperature duty by 55%. The proposed design of BHE is relatively inexpensive, more feasible and efficient, which is achieved for the first time based on a deep analysis of Dubai climate and soil. This makes the technology ready to be implemented for industrial applications in Dubai and other regions having a similar climate and soil nature.</abstract><doi>10.1002/htj.23006</doi><tpages>27</tpages><orcidid>https://orcid.org/0000-0001-5050-5187</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2688-4534
ispartof Heat transfer (Hoboken, N.J. Print), 2024-05, Vol.53 (3), p.1474-1500
issn 2688-4534
2688-4542
language eng
recordid cdi_crossref_primary_10_1002_htj_23006
source Wiley:Jisc Collections:Wiley Read and Publish Open Access 2024-2025 (reading list)
subjects boundary layer
buoyancy‐driven flow
coaxial borehole heat exchanger
geothermal energy
natural convection
soil porous media
title Design and optimization of ground‐coupled refrigeration heat exchanger in Dubai: Numerical approach
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T09%3A23%3A35IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Design%20and%20optimization%20of%20ground%E2%80%90coupled%20refrigeration%20heat%20exchanger%20in%20Dubai:%20Numerical%20approach&rft.jtitle=Heat%20transfer%20(Hoboken,%20N.J.%20Print)&rft.au=Kahwaji,%20Ghalib%20Y.&rft.date=2024-05&rft.volume=53&rft.issue=3&rft.spage=1474&rft.epage=1500&rft.pages=1474-1500&rft.issn=2688-4534&rft.eissn=2688-4542&rft_id=info:doi/10.1002/htj.23006&rft_dat=%3Cwiley_cross%3EHTJ23006%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c2296-ac9bdc14707784ff9ee924007984bf391b1c2b67921aa4ea7a969e81f9501d703%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true