Loading…
Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser
The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimenta...
Saved in:
Published in: | Laser physics letters 2008-02, Vol.5 (2), p.144-150 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483 |
---|---|
cites | cdi_FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483 |
container_end_page | 150 |
container_issue | 2 |
container_start_page | 144 |
container_title | Laser physics letters |
container_volume | 5 |
creator | Malta, D.A.M.P. Costa, M.M. Pelino, J.E.P. de Andrade, M.F. Lizarelli, R.F.Z. |
description | The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm2. The adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser. (© 2007 by Astro Ltd., Published exclusively by WILEY‐VCH Verlag GmbH & Co. KGaA) |
doi_str_mv | 10.1002/lapl.200710089 |
format | article |
fullrecord | <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_lapl_200710089</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>LAPL200710089</sourcerecordid><originalsourceid>FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483</originalsourceid><addsrcrecordid>eNqFkEtPAjEUhRujiYhuXfcPDPYxM6XukCAaJugCX6umnd5KdRhIOxH59w7BgDtX597k-87iIHRJSY8Swq4qvap6jBDRfn15hDo0pyxhhL0e729KT9FZjB-EcJIJ2UH2ZllbHJsA9Xszx0uHdY21nUP0X4DjJjawwD4Ebb1uwOK1b6mpvX4bjHGlIwTsa2yhbtpoSw7MKByYc3TidBXh4je76Ol2NBveJcXD-H44KJKSMyETw1Oms5JSkuVpX1tmpLNGGAalTm1pBDhHSilKamULGiMzIwVwEC7jkPZ5F_V2vWVYxhjAqVXwCx02ihK13UhtN1L7jVpB7oS1r2DzD62KwWPx1012rm83-t67OnyqXHCRqZfpWE0mhA1n-Uw98x9fUXu3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser</title><source>Institute of Physics</source><creator>Malta, D.A.M.P. ; Costa, M.M. ; Pelino, J.E.P. ; de Andrade, M.F. ; Lizarelli, R.F.Z.</creator><creatorcontrib>Malta, D.A.M.P. ; Costa, M.M. ; Pelino, J.E.P. ; de Andrade, M.F. ; Lizarelli, R.F.Z.</creatorcontrib><description>The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm2. The adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser. (© 2007 by Astro Ltd., Published exclusively by WILEY‐VCH Verlag GmbH & Co. KGaA)</description><identifier>ISSN: 1612-2011</identifier><identifier>EISSN: 1612-202X</identifier><identifier>DOI: 10.1002/lapl.200710089</identifier><language>eng</language><publisher>Berlin: WILEY-VCH Verlag</publisher><subject>adhesion ; dentin ; Er:YAG laser ; microtensile bond strength ; Nd:YAG laser</subject><ispartof>Laser physics letters, 2008-02, Vol.5 (2), p.144-150</ispartof><rights>Copyright © 2008 by Astro Ltd., published exclusively by WILEY‐VCH Verlag GmbH & Co. KGaA</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483</citedby><cites>FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Malta, D.A.M.P.</creatorcontrib><creatorcontrib>Costa, M.M.</creatorcontrib><creatorcontrib>Pelino, J.E.P.</creatorcontrib><creatorcontrib>de Andrade, M.F.</creatorcontrib><creatorcontrib>Lizarelli, R.F.Z.</creatorcontrib><title>Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser</title><title>Laser physics letters</title><addtitle>Laser Phys. Lett</addtitle><description>The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm2. The adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser. (© 2007 by Astro Ltd., Published exclusively by WILEY‐VCH Verlag GmbH & Co. KGaA)</description><subject>adhesion</subject><subject>dentin</subject><subject>Er:YAG laser</subject><subject>microtensile bond strength</subject><subject>Nd:YAG laser</subject><issn>1612-2011</issn><issn>1612-202X</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2008</creationdate><recordtype>article</recordtype><recordid>eNqFkEtPAjEUhRujiYhuXfcPDPYxM6XukCAaJugCX6umnd5KdRhIOxH59w7BgDtX597k-87iIHRJSY8Swq4qvap6jBDRfn15hDo0pyxhhL0e729KT9FZjB-EcJIJ2UH2ZllbHJsA9Xszx0uHdY21nUP0X4DjJjawwD4Ebb1uwOK1b6mpvX4bjHGlIwTsa2yhbtpoSw7MKByYc3TidBXh4je76Ol2NBveJcXD-H44KJKSMyETw1Oms5JSkuVpX1tmpLNGGAalTm1pBDhHSilKamULGiMzIwVwEC7jkPZ5F_V2vWVYxhjAqVXwCx02ihK13UhtN1L7jVpB7oS1r2DzD62KwWPx1012rm83-t67OnyqXHCRqZfpWE0mhA1n-Uw98x9fUXu3</recordid><startdate>200802</startdate><enddate>200802</enddate><creator>Malta, D.A.M.P.</creator><creator>Costa, M.M.</creator><creator>Pelino, J.E.P.</creator><creator>de Andrade, M.F.</creator><creator>Lizarelli, R.F.Z.</creator><general>WILEY-VCH Verlag</general><general>WILEY‐VCH Verlag</general><scope>BSCLL</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>200802</creationdate><title>Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser</title><author>Malta, D.A.M.P. ; Costa, M.M. ; Pelino, J.E.P. ; de Andrade, M.F. ; Lizarelli, R.F.Z.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2008</creationdate><topic>adhesion</topic><topic>dentin</topic><topic>Er:YAG laser</topic><topic>microtensile bond strength</topic><topic>Nd:YAG laser</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Malta, D.A.M.P.</creatorcontrib><creatorcontrib>Costa, M.M.</creatorcontrib><creatorcontrib>Pelino, J.E.P.</creatorcontrib><creatorcontrib>de Andrade, M.F.</creatorcontrib><creatorcontrib>Lizarelli, R.F.Z.</creatorcontrib><collection>Istex</collection><collection>CrossRef</collection><jtitle>Laser physics letters</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Malta, D.A.M.P.</au><au>Costa, M.M.</au><au>Pelino, J.E.P.</au><au>de Andrade, M.F.</au><au>Lizarelli, R.F.Z.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser</atitle><jtitle>Laser physics letters</jtitle><addtitle>Laser Phys. Lett</addtitle><date>2008-02</date><risdate>2008</risdate><volume>5</volume><issue>2</issue><spage>144</spage><epage>150</epage><pages>144-150</pages><issn>1612-2011</issn><eissn>1612-202X</eissn><abstract>The purpose of this in vitro study was to verify through micro tensile bond test the bond strength of an adhesive system irradiated with Nd:YAG laser in dentine previously treated with Er:YAG laser. Twenty caries free extracted human third molars were used. The teeth were divided in four experimental groups (n = 5): (G1) control group; (G2) irradiation of the adhesive system with the Nd:YAG laser; (G3) dentin treatment with Er:YAG laser; (G4) dentin treatment with Er:YAG laser followed by the irradiation of the adhesive system with Nd:YAG laser. The Er:YAG laser fluency parameter for the dentin treatment was of 60 J/cm2. The adhesive system was irradiated with the Nd:YAG laser with fluency of 100 J/cm2. Dental restorations were performed with Adper Single Bond 2/Z250. One tooth from each group was prepared for the evaluation of the adhesive interface under SEM and bond failure tests were also performed and evaluated. The statistical analysis showed statistical significant difference between the groups G1 and G3, G1 and G4, G2 and G3, and G2 and G4; and similarity between the groups G1 and G2, and G3 and G4. The adhesive failures were predominant in all the experimental groups. The SEM analysis showed an adhesive interface with features confirming the results of the mechanical tests. The Nd:YAG laser on the adhesive system did not influence the bond strength in dentin treated or not with the Er:YAG laser. (© 2007 by Astro Ltd., Published exclusively by WILEY‐VCH Verlag GmbH & Co. KGaA)</abstract><cop>Berlin</cop><pub>WILEY-VCH Verlag</pub><doi>10.1002/lapl.200710089</doi><tpages>7</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 1612-2011 |
ispartof | Laser physics letters, 2008-02, Vol.5 (2), p.144-150 |
issn | 1612-2011 1612-202X |
language | eng |
recordid | cdi_crossref_primary_10_1002_lapl_200710089 |
source | Institute of Physics |
subjects | adhesion dentin Er:YAG laser microtensile bond strength Nd:YAG laser |
title | Bond strength of an adhesive system irradiated with Nd:YAG laser in dentin treated with Er:YAG laser |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-28T23%3A30%3A44IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Bond%20strength%20of%20an%20adhesive%20system%20irradiated%20with%20Nd:YAG%20laser%20in%20dentin%20treated%20with%20Er:YAG%20laser&rft.jtitle=Laser%20physics%20letters&rft.au=Malta,%20D.A.M.P.&rft.date=2008-02&rft.volume=5&rft.issue=2&rft.spage=144&rft.epage=150&rft.pages=144-150&rft.issn=1612-2011&rft.eissn=1612-202X&rft_id=info:doi/10.1002/lapl.200710089&rft_dat=%3Cwiley_cross%3ELAPL200710089%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c3279-b342a5c1105648ad2b9fdb7b2eca4dcb7eff0c97c1d92a5bb95b97e3e7f53e483%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |