Loading…

A simplified and higher dynamic range version of the J 1 … J 4 method for optical phase measurements

A new and an improved version of the J 1 …J 4 method for optical phase detection, named J 1 –J 3 method, is described, which is more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is increased while maintaining the accuracy and the minimum detect...

Full description

Saved in:
Bibliographic Details
Published in:Microwave and optical technology letters 2012-02, Vol.54 (2), p.387-392
Main Authors: Marçal, Luiz A. P., Higuti, Ricardo T., Kitano, Cláudio
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A new and an improved version of the J 1 …J 4 method for optical phase detection, named J 1 –J 3 method, is described, which is more stable to phase drift and simpler for implementation than the original one. The sensor dynamic range is increased while maintaining the accuracy and the minimum detectable phase‐shift. The method is experimentally validated by using an electro‐optic intensity modulator. The agreement between theoretical and experimental results, based on the 1/f voltage noise, is demonstrated. © 2011 Wiley Periodicals, Inc. Microwave Opt Technol Lett, 54:387–392, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.26533
ISSN:0895-2477
1098-2760
DOI:10.1002/mop.26533