Loading…

Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse

Measurement of the fetal head biparietal diameter (BPD) and head circumference (HC) is crucial for estimation of fetal age. Due to the noisy nature of ultrasound images and variation in image acquisition and measurement techniques, manual measurements of these parameters are subject to inter‐ and in...

Full description

Saved in:
Bibliographic Details
Published in:IEEJ transactions on electrical and electronic engineering 2010-09, Vol.5 (5), p.569-573
Main Authors: Marhaban, M. H., Kaid, Rakeeb S., Mohd Noor, Samsul B.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083
cites cdi_FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083
container_end_page 573
container_issue 5
container_start_page 569
container_title IEEJ transactions on electrical and electronic engineering
container_volume 5
creator Marhaban, M. H.
Kaid, Rakeeb S.
Mohd Noor, Samsul B.
description Measurement of the fetal head biparietal diameter (BPD) and head circumference (HC) is crucial for estimation of fetal age. Due to the noisy nature of ultrasound images and variation in image acquisition and measurement techniques, manual measurements of these parameters are subject to inter‐ and intraobserver variability. In this study, we present an approach for estimation of gestational age in ultrasound images, based on direct least‐squares fitting of an ellipse. The process goes through three steps: image preprocessing, object extraction, and fitting an ellipse to the resultant shape and measuring its parameters. The proposed technique was tested and evaluated on 20 ultrasound images of fetal head. The images had a combination of noise and low contrast. Excellent linear correlation between manual and automatic measurement was obtained, which verifies the reliability of the proposed automatic approach. © 2010 Institute of Electrical Engineers of Japan. Published by John Wiley & Sons, Inc.
doi_str_mv 10.1002/tee.20574
format article
fullrecord <record><control><sourceid>wiley_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1002_tee_20574</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>TEE20574</sourcerecordid><originalsourceid>FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083</originalsourceid><addsrcrecordid>eNp1kE9PAjEQxTdGExE9-A168eBhoe323x5BFyQhehDisSndllSXXWxLlG_vwio3TzOTeb83mZcktwgOEIR4GI0ZYEg5OUt6KM9QSnKBzk89zy6TqxDeISQsE6KXbEa72GxUdBoUIbpD19SgsWBqQjwOqgKjtQGuBssqehWaXV2C2UatTQBjFUwJWuDReaMjmBsVYvr6uVO-3U5cjK5eH9yKqnLbYK6TC6uqYG5-az9ZTorFw1M6f5nOHkbzVBOISGpxbiAtMeVMMY54JrDFNtMC4xUthSitEpjZlTaMEk2ZYdAKqEjJRb6iUGT95L7z1b4JwRsrt779ze8lgvKQk2xzksecWu1dp92qoFVlvaq1CycAZ4hwTHirG3a6L1eZ_f-GclEUf85pR7gQzfeJUP5DMp5xKt-ep3I8oYwismgP_QBK_IXB</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse</title><source>Wiley-Blackwell Read &amp; Publish Collection</source><creator>Marhaban, M. H. ; Kaid, Rakeeb S. ; Mohd Noor, Samsul B.</creator><creatorcontrib>Marhaban, M. H. ; Kaid, Rakeeb S. ; Mohd Noor, Samsul B.</creatorcontrib><description>Measurement of the fetal head biparietal diameter (BPD) and head circumference (HC) is crucial for estimation of fetal age. Due to the noisy nature of ultrasound images and variation in image acquisition and measurement techniques, manual measurements of these parameters are subject to inter‐ and intraobserver variability. In this study, we present an approach for estimation of gestational age in ultrasound images, based on direct least‐squares fitting of an ellipse. The process goes through three steps: image preprocessing, object extraction, and fitting an ellipse to the resultant shape and measuring its parameters. The proposed technique was tested and evaluated on 20 ultrasound images of fetal head. The images had a combination of noise and low contrast. Excellent linear correlation between manual and automatic measurement was obtained, which verifies the reliability of the proposed automatic approach. © 2010 Institute of Electrical Engineers of Japan. Published by John Wiley &amp; Sons, Inc.</description><identifier>ISSN: 1931-4973</identifier><identifier>EISSN: 1931-4981</identifier><identifier>DOI: 10.1002/tee.20574</identifier><language>eng</language><publisher>Hoboken: Wiley Subscription Services, Inc., A Wiley Company</publisher><subject>Applied sciences ; estimation ; Exact sciences and technology ; gestational age ; Information theory ; Information, signal and communications theory ; least squares fitting ; Miscellaneous ; Signal processing ; Telecommunications and information theory ; ultrasound images</subject><ispartof>IEEJ transactions on electrical and electronic engineering, 2010-09, Vol.5 (5), p.569-573</ispartof><rights>Copyright © 2010 Institute of Electrical Engineers of Japan</rights><rights>2015 INIST-CNRS</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083</citedby><cites>FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27903,27904</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=23147247$$DView record in Pascal Francis$$Hfree_for_read</backlink></links><search><creatorcontrib>Marhaban, M. H.</creatorcontrib><creatorcontrib>Kaid, Rakeeb S.</creatorcontrib><creatorcontrib>Mohd Noor, Samsul B.</creatorcontrib><title>Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse</title><title>IEEJ transactions on electrical and electronic engineering</title><addtitle>IEEJ Trans Elec Electron Eng</addtitle><description>Measurement of the fetal head biparietal diameter (BPD) and head circumference (HC) is crucial for estimation of fetal age. Due to the noisy nature of ultrasound images and variation in image acquisition and measurement techniques, manual measurements of these parameters are subject to inter‐ and intraobserver variability. In this study, we present an approach for estimation of gestational age in ultrasound images, based on direct least‐squares fitting of an ellipse. The process goes through three steps: image preprocessing, object extraction, and fitting an ellipse to the resultant shape and measuring its parameters. The proposed technique was tested and evaluated on 20 ultrasound images of fetal head. The images had a combination of noise and low contrast. Excellent linear correlation between manual and automatic measurement was obtained, which verifies the reliability of the proposed automatic approach. © 2010 Institute of Electrical Engineers of Japan. Published by John Wiley &amp; Sons, Inc.</description><subject>Applied sciences</subject><subject>estimation</subject><subject>Exact sciences and technology</subject><subject>gestational age</subject><subject>Information theory</subject><subject>Information, signal and communications theory</subject><subject>least squares fitting</subject><subject>Miscellaneous</subject><subject>Signal processing</subject><subject>Telecommunications and information theory</subject><subject>ultrasound images</subject><issn>1931-4973</issn><issn>1931-4981</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2010</creationdate><recordtype>article</recordtype><recordid>eNp1kE9PAjEQxTdGExE9-A168eBhoe323x5BFyQhehDisSndllSXXWxLlG_vwio3TzOTeb83mZcktwgOEIR4GI0ZYEg5OUt6KM9QSnKBzk89zy6TqxDeISQsE6KXbEa72GxUdBoUIbpD19SgsWBqQjwOqgKjtQGuBssqehWaXV2C2UatTQBjFUwJWuDReaMjmBsVYvr6uVO-3U5cjK5eH9yKqnLbYK6TC6uqYG5-az9ZTorFw1M6f5nOHkbzVBOISGpxbiAtMeVMMY54JrDFNtMC4xUthSitEpjZlTaMEk2ZYdAKqEjJRb6iUGT95L7z1b4JwRsrt779ze8lgvKQk2xzksecWu1dp92qoFVlvaq1CycAZ4hwTHirG3a6L1eZ_f-GclEUf85pR7gQzfeJUP5DMp5xKt-ep3I8oYwismgP_QBK_IXB</recordid><startdate>201009</startdate><enddate>201009</enddate><creator>Marhaban, M. H.</creator><creator>Kaid, Rakeeb S.</creator><creator>Mohd Noor, Samsul B.</creator><general>Wiley Subscription Services, Inc., A Wiley Company</general><general>Wiley</general><scope>BSCLL</scope><scope>IQODW</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>201009</creationdate><title>Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse</title><author>Marhaban, M. H. ; Kaid, Rakeeb S. ; Mohd Noor, Samsul B.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2010</creationdate><topic>Applied sciences</topic><topic>estimation</topic><topic>Exact sciences and technology</topic><topic>gestational age</topic><topic>Information theory</topic><topic>Information, signal and communications theory</topic><topic>least squares fitting</topic><topic>Miscellaneous</topic><topic>Signal processing</topic><topic>Telecommunications and information theory</topic><topic>ultrasound images</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Marhaban, M. H.</creatorcontrib><creatorcontrib>Kaid, Rakeeb S.</creatorcontrib><creatorcontrib>Mohd Noor, Samsul B.</creatorcontrib><collection>Istex</collection><collection>Pascal-Francis</collection><collection>CrossRef</collection><jtitle>IEEJ transactions on electrical and electronic engineering</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Marhaban, M. H.</au><au>Kaid, Rakeeb S.</au><au>Mohd Noor, Samsul B.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse</atitle><jtitle>IEEJ transactions on electrical and electronic engineering</jtitle><addtitle>IEEJ Trans Elec Electron Eng</addtitle><date>2010-09</date><risdate>2010</risdate><volume>5</volume><issue>5</issue><spage>569</spage><epage>573</epage><pages>569-573</pages><issn>1931-4973</issn><eissn>1931-4981</eissn><abstract>Measurement of the fetal head biparietal diameter (BPD) and head circumference (HC) is crucial for estimation of fetal age. Due to the noisy nature of ultrasound images and variation in image acquisition and measurement techniques, manual measurements of these parameters are subject to inter‐ and intraobserver variability. In this study, we present an approach for estimation of gestational age in ultrasound images, based on direct least‐squares fitting of an ellipse. The process goes through three steps: image preprocessing, object extraction, and fitting an ellipse to the resultant shape and measuring its parameters. The proposed technique was tested and evaluated on 20 ultrasound images of fetal head. The images had a combination of noise and low contrast. Excellent linear correlation between manual and automatic measurement was obtained, which verifies the reliability of the proposed automatic approach. © 2010 Institute of Electrical Engineers of Japan. Published by John Wiley &amp; Sons, Inc.</abstract><cop>Hoboken</cop><pub>Wiley Subscription Services, Inc., A Wiley Company</pub><doi>10.1002/tee.20574</doi><tpages>5</tpages><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 1931-4973
ispartof IEEJ transactions on electrical and electronic engineering, 2010-09, Vol.5 (5), p.569-573
issn 1931-4973
1931-4981
language eng
recordid cdi_crossref_primary_10_1002_tee_20574
source Wiley-Blackwell Read & Publish Collection
subjects Applied sciences
estimation
Exact sciences and technology
gestational age
Information theory
Information, signal and communications theory
least squares fitting
Miscellaneous
Signal processing
Telecommunications and information theory
ultrasound images
title Automatic Estimation of Gestational Age in Ultrasound Images Based on Direct Least-Squares Fitting of Ellipse
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-26T17%3A56%3A08IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-wiley_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Automatic%20Estimation%20of%20Gestational%20Age%20in%20Ultrasound%20Images%20Based%20on%20Direct%20Least-Squares%20Fitting%20of%20Ellipse&rft.jtitle=IEEJ%20transactions%20on%20electrical%20and%20electronic%20engineering&rft.au=Marhaban,%20M.%20H.&rft.date=2010-09&rft.volume=5&rft.issue=5&rft.spage=569&rft.epage=573&rft.pages=569-573&rft.issn=1931-4973&rft.eissn=1931-4981&rft_id=info:doi/10.1002/tee.20574&rft_dat=%3Cwiley_cross%3ETEE20574%3C/wiley_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c4014-f29e05d2576a6717382f2f3c822b5d88dfa826fbce654c56e60f80a4d789b5083%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true