Loading…

Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits

In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA an...

Full description

Saved in:
Bibliographic Details
Published in:European Journal of Nuclear Medicine 1993-06, Vol.20 (6), p.465-472
Main Authors: VANBILLOEN, H. P, VERBEKE, K. A, DE ROO, M. J, VERBRUGGEN, A. M
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c226t-d6859c361c5b620f5b3e62142a8d89c9e55185b257bf3cab265b9b69e6a66b963
cites
container_end_page 472
container_issue 6
container_start_page 465
container_title European Journal of Nuclear Medicine
container_volume 20
creator VANBILLOEN, H. P
VERBEKE, K. A
DE ROO, M. J
VERBRUGGEN, A. M
description In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%-70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.
doi_str_mv 10.1007/BF00175158
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00175158</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>75882253</sourcerecordid><originalsourceid>FETCH-LOGICAL-c226t-d6859c361c5b620f5b3e62142a8d89c9e55185b257bf3cab265b9b69e6a66b963</originalsourceid><addsrcrecordid>eNpFkEtLJDEUhcPgoO1j417IQlwINZNH5eVOxRc0zMZZFzfplB2tVLVJpZn-99Zgoat74Hx8XA5Cp5T8ooSo3zf3hFAlqNA_0IJKaipFtNlDC8JrUklj1AE6zPmVEFLXXOyjfc25Ucws0Puzd-vej6HEypiIO7C-6_wKr0uEHmefSsTQ2RJDj9sh4a3vxxRc6YaXBJv1Dl9hwG6IG0gwhq3HfgtdmeLQ46HFOfybnaF_wW9hzMfoZwtd9ifzPUJ_7--ebx-r5Z-Hp9vrZeUYk2O1kloYxyV1wkpGWmG5l4zWDPRKG2e8EFQLy4SyLXdgmRTWWGm8BCmtkfwIXXx6N2l4Lz6PTQzZTY9A74eSGyW0ZkzwCbz8BF0ack6-bTYpREi7hpLm_77N974TfDZbi41-9YXOg079-dxDdtC1CXoX8hdWK2UoqfkHhdKCvA</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>75882253</pqid></control><display><type>article</type><title>Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits</title><source>Alma/SFX Local Collection</source><creator>VANBILLOEN, H. P ; VERBEKE, K. A ; DE ROO, M. J ; VERBRUGGEN, A. M</creator><creatorcontrib>VANBILLOEN, H. P ; VERBEKE, K. A ; DE ROO, M. J ; VERBRUGGEN, A. M</creatorcontrib><description>In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%-70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00175158</identifier><identifier>PMID: 8339729</identifier><identifier>CODEN: EJNMD9</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Animals ; Biological and medical sciences ; Contrast media. Radiopharmaceuticals ; Humans ; Medical sciences ; Mice ; Pharmacology. Drug treatments ; Rabbits ; Radionuclide Ventriculography ; Reagent Kits, Diagnostic ; Technetium Tc 99m Aggregated Albumin - blood ; Technetium Tc 99m Aggregated Albumin - pharmacokinetics ; Tissue Distribution</subject><ispartof>European Journal of Nuclear Medicine, 1993-06, Vol.20 (6), p.465-472</ispartof><rights>1993 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c226t-d6859c361c5b620f5b3e62142a8d89c9e55185b257bf3cab265b9b69e6a66b963</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=4779104$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/8339729$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>VANBILLOEN, H. P</creatorcontrib><creatorcontrib>VERBEKE, K. A</creatorcontrib><creatorcontrib>DE ROO, M. J</creatorcontrib><creatorcontrib>VERBRUGGEN, A. M</creatorcontrib><title>Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%-70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.</description><subject>Animals</subject><subject>Biological and medical sciences</subject><subject>Contrast media. Radiopharmaceuticals</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Mice</subject><subject>Pharmacology. Drug treatments</subject><subject>Rabbits</subject><subject>Radionuclide Ventriculography</subject><subject>Reagent Kits, Diagnostic</subject><subject>Technetium Tc 99m Aggregated Albumin - blood</subject><subject>Technetium Tc 99m Aggregated Albumin - pharmacokinetics</subject><subject>Tissue Distribution</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1993</creationdate><recordtype>article</recordtype><recordid>eNpFkEtLJDEUhcPgoO1j417IQlwINZNH5eVOxRc0zMZZFzfplB2tVLVJpZn-99Zgoat74Hx8XA5Cp5T8ooSo3zf3hFAlqNA_0IJKaipFtNlDC8JrUklj1AE6zPmVEFLXXOyjfc25Ucws0Puzd-vej6HEypiIO7C-6_wKr0uEHmefSsTQ2RJDj9sh4a3vxxRc6YaXBJv1Dl9hwG6IG0gwhq3HfgtdmeLQ46HFOfybnaF_wW9hzMfoZwtd9ifzPUJ_7--ebx-r5Z-Hp9vrZeUYk2O1kloYxyV1wkpGWmG5l4zWDPRKG2e8EFQLy4SyLXdgmRTWWGm8BCmtkfwIXXx6N2l4Lz6PTQzZTY9A74eSGyW0ZkzwCbz8BF0ack6-bTYpREi7hpLm_77N974TfDZbi41-9YXOg079-dxDdtC1CXoX8hdWK2UoqfkHhdKCvA</recordid><startdate>199306</startdate><enddate>199306</enddate><creator>VANBILLOEN, H. P</creator><creator>VERBEKE, K. A</creator><creator>DE ROO, M. J</creator><creator>VERBRUGGEN, A. M</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199306</creationdate><title>Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits</title><author>VANBILLOEN, H. P ; VERBEKE, K. A ; DE ROO, M. J ; VERBRUGGEN, A. M</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c226t-d6859c361c5b620f5b3e62142a8d89c9e55185b257bf3cab265b9b69e6a66b963</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1993</creationdate><topic>Animals</topic><topic>Biological and medical sciences</topic><topic>Contrast media. Radiopharmaceuticals</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Mice</topic><topic>Pharmacology. Drug treatments</topic><topic>Rabbits</topic><topic>Radionuclide Ventriculography</topic><topic>Reagent Kits, Diagnostic</topic><topic>Technetium Tc 99m Aggregated Albumin - blood</topic><topic>Technetium Tc 99m Aggregated Albumin - pharmacokinetics</topic><topic>Tissue Distribution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>VANBILLOEN, H. P</creatorcontrib><creatorcontrib>VERBEKE, K. A</creatorcontrib><creatorcontrib>DE ROO, M. J</creatorcontrib><creatorcontrib>VERBRUGGEN, A. M</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>VANBILLOEN, H. P</au><au>VERBEKE, K. A</au><au>DE ROO, M. J</au><au>VERBRUGGEN, A. M</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1993-06</date><risdate>1993</risdate><volume>20</volume><issue>6</issue><spage>465</spage><epage>472</epage><pages>465-472</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><coden>EJNMD9</coden><abstract>In this study we have compared the characteristics of six labelling kits for the preparation of technetium-99m labelled human serum albumin (99mTc-HSA) and evaluated the usefulness of the various 99mTc-HSA preparations as blood pool tracer agents. The amount of the principal ingredients, i.e. HSA and stannous ions, varies largely between the studied kits and this is probably a reason for the observed differences in the labelling rate. Analysis of the reaction mixtures after labelling of the respective kits with 99mTc showed in each preparation the presence of four to five radioactive components in variable relative amounts. The retention time of the main component on size-exclusion high-performance liquid chromatography (SEC-HPLC) was identical for all preparations. Biodistribution of the HPLC-isolated fractions was studied in mice. The components with the shortest and longest retention times on HPLC show poor retention in the plasma. The three intermediate fractions, including the principal peak, are initially retained relatively well in the blood (60%-70% of the injected dose after 10 min), but clearly to a lower degree than iodine-125 labelled HSA. Moreover, they diffuse out of the vascular compartment at a much higher rate than 125I-HSA. The biological behaviour of the main component of the various preparations was clearly different, despite the identical retention time on SEC-HPLC. Study of the total preparations in mice and a rabbit showed that two of them are cleared rapidly from the blood and cannot be considered valuable blood pool tracers. Diffusion of the other preparations out of the blood is slower but also considerable and compromises their use for ventriculography.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>8339729</pmid><doi>10.1007/BF00175158</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal of Nuclear Medicine, 1993-06, Vol.20 (6), p.465-472
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00175158
source Alma/SFX Local Collection
subjects Animals
Biological and medical sciences
Contrast media. Radiopharmaceuticals
Humans
Medical sciences
Mice
Pharmacology. Drug treatments
Rabbits
Radionuclide Ventriculography
Reagent Kits, Diagnostic
Technetium Tc 99m Aggregated Albumin - blood
Technetium Tc 99m Aggregated Albumin - pharmacokinetics
Tissue Distribution
title Technetium-99m labelled human serum albumin for ventriculography : a comparative evaluation of six labelling kits
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T22%3A36%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Technetium-99m%20labelled%20human%20serum%20albumin%20for%20ventriculography%20:%20a%20comparative%20evaluation%20of%20six%20labelling%20kits&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=VANBILLOEN,%20H.%20P&rft.date=1993-06&rft.volume=20&rft.issue=6&rft.spage=465&rft.epage=472&rft.pages=465-472&rft.issn=0340-6997&rft.eissn=1619-7089&rft.coden=EJNMD9&rft_id=info:doi/10.1007/BF00175158&rft_dat=%3Cproquest_cross%3E75882253%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c226t-d6859c361c5b620f5b3e62142a8d89c9e55185b257bf3cab265b9b69e6a66b963%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=75882253&rft_id=info:pmid/8339729&rfr_iscdi=true