Loading…

The imaging of myocardial perfusion with 81mKr during coronary arteriography

The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each arter...

Full description

Saved in:
Bibliographic Details
Published in:European Journal of Nuclear Medicine 1982, Vol.7 (9), p.405-409
Main Authors: Kleynhans, P H, Lötter, M G, van Aswegen, A, Herbst, C P, Marx, J D, Minnaar, P C
Format: Article
Language:English
Subjects:
Citations: Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c1299-abce437571b65d5e62d3c0bfacdeb0f32accfc1ed77341fb323954c5d33ddf23
cites
container_end_page 409
container_issue 9
container_start_page 405
container_title European Journal of Nuclear Medicine
container_volume 7
creator Kleynhans, P H
Lötter, M G
van Aswegen, A
Herbst, C P
Marx, J D
Minnaar, P C
description The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each artery separately evaluated. The distribution of 81mKr, due to its 13-s half-life, represents regional blood flow. In order to evaluate interventions, studies can be repeated at a low radiation risk to patients. A sterile pyrogen-free 81Rb-81Kr generator was developed. With slow infusion, inadequate mixing and streaming takes place due to laminar flow in coronary arteries. Fast intermittent 3-ml 81Kr-dextrose bolus injections convincingly eliminated streaming artefacts. Imaging was performed in 13 patients with a mobile scintillation camera and digital imaging system. Blood flow was calculated using the inert gas washout technique. There was good correlation (r = 0.91) between coronary blood flow determinations using 81mKr and 133Xe respectively. The perfusion images correlated well with the coronary angiograms. Total coronary arterial occlusions as demonstrated by arteriography were all shown as perfusion defects during rest. During atrial pacing myocardial flow was increased two-fold in normal coronary arteries and to a lesser extent in arteries with significant disease. The most critical lesion in a branch of a left coronary artery leads to a redistribution of perfusion during pacing.
doi_str_mv 10.1007/BF00256819
format article
fullrecord <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00256819</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>74252316</sourcerecordid><originalsourceid>FETCH-LOGICAL-c1299-abce437571b65d5e62d3c0bfacdeb0f32accfc1ed77341fb323954c5d33ddf23</originalsourceid><addsrcrecordid>eNpF0M1LwzAYx_EgypzTi3chJw9CNe9pjjqcigMvu5c0L1ukbWqyIv3vt7Ghp-fy4QfPF4BbjB4xQvLpZYEQ4aLE6gxMscCqkKhU52CKKEOFUEpegqucvxFCjFE-AROJSSmImoLlauNgaPU6dGsYPWzHaHSyQTewd8kPOcQO_obtBpa4_UzQDukgTUyx02mEOm1dCnGddL8Zr8GF1012N6c7A6vF62r-Xiy_3j7mz8vCYKJUoWvjGJVc4lpwy50glhpUe22sq5GnRBvjDXZWSsqwrymhijPDLaXWekJn4P4426f4M7i8rdqQjWsa3bk45EoywgnFYg8fjtCkmHNyvurT_tc0VhhVh3LVf7k9vjutDnXr7B89paI7CvxpcQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>74252316</pqid></control><display><type>article</type><title>The imaging of myocardial perfusion with 81mKr during coronary arteriography</title><source>Alma/SFX Local Collection</source><creator>Kleynhans, P H ; Lötter, M G ; van Aswegen, A ; Herbst, C P ; Marx, J D ; Minnaar, P C</creator><creatorcontrib>Kleynhans, P H ; Lötter, M G ; van Aswegen, A ; Herbst, C P ; Marx, J D ; Minnaar, P C</creatorcontrib><description>The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each artery separately evaluated. The distribution of 81mKr, due to its 13-s half-life, represents regional blood flow. In order to evaluate interventions, studies can be repeated at a low radiation risk to patients. A sterile pyrogen-free 81Rb-81Kr generator was developed. With slow infusion, inadequate mixing and streaming takes place due to laminar flow in coronary arteries. Fast intermittent 3-ml 81Kr-dextrose bolus injections convincingly eliminated streaming artefacts. Imaging was performed in 13 patients with a mobile scintillation camera and digital imaging system. Blood flow was calculated using the inert gas washout technique. There was good correlation (r = 0.91) between coronary blood flow determinations using 81mKr and 133Xe respectively. The perfusion images correlated well with the coronary angiograms. Total coronary arterial occlusions as demonstrated by arteriography were all shown as perfusion defects during rest. During atrial pacing myocardial flow was increased two-fold in normal coronary arteries and to a lesser extent in arteries with significant disease. The most critical lesion in a branch of a left coronary artery leads to a redistribution of perfusion during pacing.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00256819</identifier><identifier>PMID: 7128629</identifier><language>eng</language><publisher>Germany</publisher><subject>Angiography ; Coronary Disease - diagnostic imaging ; Humans ; Krypton ; Radioisotopes ; Radionuclide Generators ; Radionuclide Imaging</subject><ispartof>European Journal of Nuclear Medicine, 1982, Vol.7 (9), p.405-409</ispartof><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c1299-abce437571b65d5e62d3c0bfacdeb0f32accfc1ed77341fb323954c5d33ddf23</citedby></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,4024,27923,27924,27925</link.rule.ids><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/7128629$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>Kleynhans, P H</creatorcontrib><creatorcontrib>Lötter, M G</creatorcontrib><creatorcontrib>van Aswegen, A</creatorcontrib><creatorcontrib>Herbst, C P</creatorcontrib><creatorcontrib>Marx, J D</creatorcontrib><creatorcontrib>Minnaar, P C</creatorcontrib><title>The imaging of myocardial perfusion with 81mKr during coronary arteriography</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each artery separately evaluated. The distribution of 81mKr, due to its 13-s half-life, represents regional blood flow. In order to evaluate interventions, studies can be repeated at a low radiation risk to patients. A sterile pyrogen-free 81Rb-81Kr generator was developed. With slow infusion, inadequate mixing and streaming takes place due to laminar flow in coronary arteries. Fast intermittent 3-ml 81Kr-dextrose bolus injections convincingly eliminated streaming artefacts. Imaging was performed in 13 patients with a mobile scintillation camera and digital imaging system. Blood flow was calculated using the inert gas washout technique. There was good correlation (r = 0.91) between coronary blood flow determinations using 81mKr and 133Xe respectively. The perfusion images correlated well with the coronary angiograms. Total coronary arterial occlusions as demonstrated by arteriography were all shown as perfusion defects during rest. During atrial pacing myocardial flow was increased two-fold in normal coronary arteries and to a lesser extent in arteries with significant disease. The most critical lesion in a branch of a left coronary artery leads to a redistribution of perfusion during pacing.</description><subject>Angiography</subject><subject>Coronary Disease - diagnostic imaging</subject><subject>Humans</subject><subject>Krypton</subject><subject>Radioisotopes</subject><subject>Radionuclide Generators</subject><subject>Radionuclide Imaging</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1982</creationdate><recordtype>article</recordtype><recordid>eNpF0M1LwzAYx_EgypzTi3chJw9CNe9pjjqcigMvu5c0L1ukbWqyIv3vt7Ghp-fy4QfPF4BbjB4xQvLpZYEQ4aLE6gxMscCqkKhU52CKKEOFUEpegqucvxFCjFE-AROJSSmImoLlauNgaPU6dGsYPWzHaHSyQTewd8kPOcQO_obtBpa4_UzQDukgTUyx02mEOm1dCnGddL8Zr8GF1012N6c7A6vF62r-Xiy_3j7mz8vCYKJUoWvjGJVc4lpwy50glhpUe22sq5GnRBvjDXZWSsqwrymhijPDLaXWekJn4P4426f4M7i8rdqQjWsa3bk45EoywgnFYg8fjtCkmHNyvurT_tc0VhhVh3LVf7k9vjutDnXr7B89paI7CvxpcQ</recordid><startdate>1982</startdate><enddate>1982</enddate><creator>Kleynhans, P H</creator><creator>Lötter, M G</creator><creator>van Aswegen, A</creator><creator>Herbst, C P</creator><creator>Marx, J D</creator><creator>Minnaar, P C</creator><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>1982</creationdate><title>The imaging of myocardial perfusion with 81mKr during coronary arteriography</title><author>Kleynhans, P H ; Lötter, M G ; van Aswegen, A ; Herbst, C P ; Marx, J D ; Minnaar, P C</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c1299-abce437571b65d5e62d3c0bfacdeb0f32accfc1ed77341fb323954c5d33ddf23</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1982</creationdate><topic>Angiography</topic><topic>Coronary Disease - diagnostic imaging</topic><topic>Humans</topic><topic>Krypton</topic><topic>Radioisotopes</topic><topic>Radionuclide Generators</topic><topic>Radionuclide Imaging</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Kleynhans, P H</creatorcontrib><creatorcontrib>Lötter, M G</creatorcontrib><creatorcontrib>van Aswegen, A</creatorcontrib><creatorcontrib>Herbst, C P</creatorcontrib><creatorcontrib>Marx, J D</creatorcontrib><creatorcontrib>Minnaar, P C</creatorcontrib><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Kleynhans, P H</au><au>Lötter, M G</au><au>van Aswegen, A</au><au>Herbst, C P</au><au>Marx, J D</au><au>Minnaar, P C</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The imaging of myocardial perfusion with 81mKr during coronary arteriography</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1982</date><risdate>1982</risdate><volume>7</volume><issue>9</issue><spage>405</spage><epage>409</epage><pages>405-409</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><abstract>The use of 81mKr was investigated for imaging myocardial perfusion during coronary arteriography using conventional catheters. When the significance of stenosis judged by arteriography is unclear, the effect on tissue perfusion can be established and the contribution to collateral flow by each artery separately evaluated. The distribution of 81mKr, due to its 13-s half-life, represents regional blood flow. In order to evaluate interventions, studies can be repeated at a low radiation risk to patients. A sterile pyrogen-free 81Rb-81Kr generator was developed. With slow infusion, inadequate mixing and streaming takes place due to laminar flow in coronary arteries. Fast intermittent 3-ml 81Kr-dextrose bolus injections convincingly eliminated streaming artefacts. Imaging was performed in 13 patients with a mobile scintillation camera and digital imaging system. Blood flow was calculated using the inert gas washout technique. There was good correlation (r = 0.91) between coronary blood flow determinations using 81mKr and 133Xe respectively. The perfusion images correlated well with the coronary angiograms. Total coronary arterial occlusions as demonstrated by arteriography were all shown as perfusion defects during rest. During atrial pacing myocardial flow was increased two-fold in normal coronary arteries and to a lesser extent in arteries with significant disease. The most critical lesion in a branch of a left coronary artery leads to a redistribution of perfusion during pacing.</abstract><cop>Germany</cop><pmid>7128629</pmid><doi>10.1007/BF00256819</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal of Nuclear Medicine, 1982, Vol.7 (9), p.405-409
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00256819
source Alma/SFX Local Collection
subjects Angiography
Coronary Disease - diagnostic imaging
Humans
Krypton
Radioisotopes
Radionuclide Generators
Radionuclide Imaging
title The imaging of myocardial perfusion with 81mKr during coronary arteriography
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-01T14%3A40%3A38IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20imaging%20of%20myocardial%20perfusion%20with%2081mKr%20during%20coronary%20arteriography&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=Kleynhans,%20P%20H&rft.date=1982&rft.volume=7&rft.issue=9&rft.spage=405&rft.epage=409&rft.pages=405-409&rft.issn=0340-6997&rft.eissn=1619-7089&rft_id=info:doi/10.1007/BF00256819&rft_dat=%3Cproquest_cross%3E74252316%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c1299-abce437571b65d5e62d3c0bfacdeb0f32accfc1ed77341fb323954c5d33ddf23%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=74252316&rft_id=info:pmid/7128629&rfr_iscdi=true