Loading…

Effective dose equivalent from radiopharmaceuticals

The concept of "effective dose equivalent", which was introduced by the International Commission on Radiological Protection (ICRP) for occupationally exposed workers, has also created the possibility of expressing by means of a single figure, the radiation risk to patients undergoing diffe...

Full description

Saved in:
Bibliographic Details
Published in:European Journal of Nuclear Medicine 1984-01, Vol.9 (11), p.485-489
Main Authors: JOHANSSON, L, MATTSON, S, NOSSLIN, B
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13
cites cdi_FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13
container_end_page 489
container_issue 11
container_start_page 485
container_title European Journal of Nuclear Medicine
container_volume 9
creator JOHANSSON, L
MATTSON, S
NOSSLIN, B
description The concept of "effective dose equivalent", which was introduced by the International Commission on Radiological Protection (ICRP) for occupationally exposed workers, has also created the possibility of expressing by means of a single figure, the radiation risk to patients undergoing different medical radiodiagnostic procedures. In this study, we present the effective dose equivalent for various nuclear-medicine investigations. The figures given are primarily based on a review of data contained in the literature on the mean absorbed dose to various organs. In many cases, however, our own calculations, using biokinetic data derived from the literature, have been used. It was found that for the different radiopharmaceuticals, the effective dose equivalent per activity unit administered extends over an interval of five orders of magnitude, from 0.00015 to 20 mSv/MBq. For the technetium-labelled compounds, the absorbed dose for 90% of the substances lies within the narrower interval between 0.0060 and 0.025 mSv/MBq. With the aid of the figures presented, each nuclear medicine department will be able to estimate the effective dose equivalent and, hence, the risk to patients undergoing different investigations.
doi_str_mv 10.1007/BF00263250
format article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00263250</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>6519109</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13</originalsourceid><addsrcrecordid>eNpFj01Lw0AURQdRaqxu3AtZuBKi72W-MkstrQoFN7oOk5kXjDRNnEkL_nsjDXV1L9zDhcPYNcI9AuiHpxVArngu4YQlqNBkGgpzyhLgAjJljD5nFzF-AYAQXM7YTEk0CCZhfFnX5IZmT6nvIqX0vWv2dkPbIa1D16bB-qbrP21oraPd0Di7iZfsrB6Drqacs4_V8n3xkq3fnl8Xj-vMccQhIyy8wpwqYaDSGoUmAZJAWaM1iMJaC1L53KMpxkZC5eSkrLBSueQe-ZzdHX5d6GIMVJd9aFobfkqE8k-8_Bcf4ZsD3O-qlvwRnUzH_XbabRwl6mC3rolHzKBWshD8F_igXhE</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effective dose equivalent from radiopharmaceuticals</title><source>Alma/SFX Local Collection</source><creator>JOHANSSON, L ; MATTSON, S ; NOSSLIN, B</creator><creatorcontrib>JOHANSSON, L ; MATTSON, S ; NOSSLIN, B</creatorcontrib><description>The concept of "effective dose equivalent", which was introduced by the International Commission on Radiological Protection (ICRP) for occupationally exposed workers, has also created the possibility of expressing by means of a single figure, the radiation risk to patients undergoing different medical radiodiagnostic procedures. In this study, we present the effective dose equivalent for various nuclear-medicine investigations. The figures given are primarily based on a review of data contained in the literature on the mean absorbed dose to various organs. In many cases, however, our own calculations, using biokinetic data derived from the literature, have been used. It was found that for the different radiopharmaceuticals, the effective dose equivalent per activity unit administered extends over an interval of five orders of magnitude, from 0.00015 to 20 mSv/MBq. For the technetium-labelled compounds, the absorbed dose for 90% of the substances lies within the narrower interval between 0.0060 and 0.025 mSv/MBq. With the aid of the figures presented, each nuclear medicine department will be able to estimate the effective dose equivalent and, hence, the risk to patients undergoing different investigations.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00263250</identifier><identifier>PMID: 6519109</identifier><identifier>CODEN: EJNMD9</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Adult ; Biological and medical sciences ; Contrast media. Radiopharmaceuticals ; Humans ; Medical sciences ; Pharmacology. Drug treatments ; Radiation Dosage ; Radioisotopes</subject><ispartof>European Journal of Nuclear Medicine, 1984-01, Vol.9 (11), p.485-489</ispartof><rights>1985 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13</citedby><cites>FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27922,27923</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=9176584$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/6519109$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>JOHANSSON, L</creatorcontrib><creatorcontrib>MATTSON, S</creatorcontrib><creatorcontrib>NOSSLIN, B</creatorcontrib><title>Effective dose equivalent from radiopharmaceuticals</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>The concept of "effective dose equivalent", which was introduced by the International Commission on Radiological Protection (ICRP) for occupationally exposed workers, has also created the possibility of expressing by means of a single figure, the radiation risk to patients undergoing different medical radiodiagnostic procedures. In this study, we present the effective dose equivalent for various nuclear-medicine investigations. The figures given are primarily based on a review of data contained in the literature on the mean absorbed dose to various organs. In many cases, however, our own calculations, using biokinetic data derived from the literature, have been used. It was found that for the different radiopharmaceuticals, the effective dose equivalent per activity unit administered extends over an interval of five orders of magnitude, from 0.00015 to 20 mSv/MBq. For the technetium-labelled compounds, the absorbed dose for 90% of the substances lies within the narrower interval between 0.0060 and 0.025 mSv/MBq. With the aid of the figures presented, each nuclear medicine department will be able to estimate the effective dose equivalent and, hence, the risk to patients undergoing different investigations.</description><subject>Adult</subject><subject>Biological and medical sciences</subject><subject>Contrast media. Radiopharmaceuticals</subject><subject>Humans</subject><subject>Medical sciences</subject><subject>Pharmacology. Drug treatments</subject><subject>Radiation Dosage</subject><subject>Radioisotopes</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1984</creationdate><recordtype>article</recordtype><recordid>eNpFj01Lw0AURQdRaqxu3AtZuBKi72W-MkstrQoFN7oOk5kXjDRNnEkL_nsjDXV1L9zDhcPYNcI9AuiHpxVArngu4YQlqNBkGgpzyhLgAjJljD5nFzF-AYAQXM7YTEk0CCZhfFnX5IZmT6nvIqX0vWv2dkPbIa1D16bB-qbrP21oraPd0Di7iZfsrB6Drqacs4_V8n3xkq3fnl8Xj-vMccQhIyy8wpwqYaDSGoUmAZJAWaM1iMJaC1L53KMpxkZC5eSkrLBSueQe-ZzdHX5d6GIMVJd9aFobfkqE8k-8_Bcf4ZsD3O-qlvwRnUzH_XbabRwl6mC3rolHzKBWshD8F_igXhE</recordid><startdate>19840101</startdate><enddate>19840101</enddate><creator>JOHANSSON, L</creator><creator>MATTSON, S</creator><creator>NOSSLIN, B</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19840101</creationdate><title>Effective dose equivalent from radiopharmaceuticals</title><author>JOHANSSON, L ; MATTSON, S ; NOSSLIN, B</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1984</creationdate><topic>Adult</topic><topic>Biological and medical sciences</topic><topic>Contrast media. Radiopharmaceuticals</topic><topic>Humans</topic><topic>Medical sciences</topic><topic>Pharmacology. Drug treatments</topic><topic>Radiation Dosage</topic><topic>Radioisotopes</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>JOHANSSON, L</creatorcontrib><creatorcontrib>MATTSON, S</creatorcontrib><creatorcontrib>NOSSLIN, B</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>JOHANSSON, L</au><au>MATTSON, S</au><au>NOSSLIN, B</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effective dose equivalent from radiopharmaceuticals</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1984-01-01</date><risdate>1984</risdate><volume>9</volume><issue>11</issue><spage>485</spage><epage>489</epage><pages>485-489</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><coden>EJNMD9</coden><abstract>The concept of "effective dose equivalent", which was introduced by the International Commission on Radiological Protection (ICRP) for occupationally exposed workers, has also created the possibility of expressing by means of a single figure, the radiation risk to patients undergoing different medical radiodiagnostic procedures. In this study, we present the effective dose equivalent for various nuclear-medicine investigations. The figures given are primarily based on a review of data contained in the literature on the mean absorbed dose to various organs. In many cases, however, our own calculations, using biokinetic data derived from the literature, have been used. It was found that for the different radiopharmaceuticals, the effective dose equivalent per activity unit administered extends over an interval of five orders of magnitude, from 0.00015 to 20 mSv/MBq. For the technetium-labelled compounds, the absorbed dose for 90% of the substances lies within the narrower interval between 0.0060 and 0.025 mSv/MBq. With the aid of the figures presented, each nuclear medicine department will be able to estimate the effective dose equivalent and, hence, the risk to patients undergoing different investigations.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>6519109</pmid><doi>10.1007/BF00263250</doi><tpages>5</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal of Nuclear Medicine, 1984-01, Vol.9 (11), p.485-489
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00263250
source Alma/SFX Local Collection
subjects Adult
Biological and medical sciences
Contrast media. Radiopharmaceuticals
Humans
Medical sciences
Pharmacology. Drug treatments
Radiation Dosage
Radioisotopes
title Effective dose equivalent from radiopharmaceuticals
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-14T14%3A21%3A56IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effective%20dose%20equivalent%20from%20radiopharmaceuticals&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=JOHANSSON,%20L&rft.date=1984-01-01&rft.volume=9&rft.issue=11&rft.spage=485&rft.epage=489&rft.pages=485-489&rft.issn=0340-6997&rft.eissn=1619-7089&rft.coden=EJNMD9&rft_id=info:doi/10.1007/BF00263250&rft_dat=%3Cpubmed_cross%3E6519109%3C/pubmed_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c311t-e18d612eb490b77147e405e06a977048aaa056d2d198a05e462ec55b1b6253d13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/6519109&rfr_iscdi=true