Loading…

Monte Carlo estimates of absorbed dose rate in various tissues and organs

A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agre...

Full description

Saved in:
Bibliographic Details
Published in:European Journal Of Nuclear Medicine 1987-01, Vol.13 (3), p.109-114
Main Authors: MURASE, K, KATAOKA, M, YASUHARA, Y, ISHINE, M, KAWAMURA, M, IIO, A, HAMAMOTO, K
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723
cites cdi_FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723
container_end_page 114
container_issue 3
container_start_page 109
container_title European Journal Of Nuclear Medicine
container_volume 13
creator MURASE, K
KATAOKA, M
YASUHARA, Y
ISHINE, M
KAWAMURA, M
IIO, A
HAMAMOTO, K
description A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agreement with those obtained by the moments method was found within an error of several percent. In comparing with experiment and other Monte Carlo results, good agreement was also obtained within the range of statistical error. The absorbed dose rate for an 123I, 124I, 125I, 126I and 99mTc point source and their specific dose constants in various tissues and organs were calculated using this program. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be extended to various radionuclides used in nuclear medicine by adding their nuclear data to the program.
doi_str_mv 10.1007/BF00289020
format article
fullrecord <record><control><sourceid>pubmed_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF00289020</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>3622553</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723</originalsourceid><addsrcrecordid>eNpFkM1LAzEQxYMotVYv3oUcPAmrk-_NUYvVQsWLnpfsJpGVdlMyW8H_3kiLnubj_RjePEIuGdwyAHP3sADgtQUOR2TKNLOVgdoekykICZW21pySM8RPAJBSqAmZCM25UmJKli9pGAOdu7xONODYb9wYkKZIXYspt8FTnzDQXNa0H-iXy33aIR17xF0B3eBpyh9uwHNyEt0aw8Whzsj74vFt_lytXp-W8_tV1QnGxioqo5zySngIQukanPAhCi1lZzvGeQ2ca8Oi9CZyoV1ptWKsrT2U0XAxIzf7u11OiDnEZpuL6_zdMGh-42j-4yjw1R7e7tpN8H_o4f-iXx90h51bx-yGrsc_zAgrldTiByJeZRU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Monte Carlo estimates of absorbed dose rate in various tissues and organs</title><source>Alma/SFX Local Collection</source><creator>MURASE, K ; KATAOKA, M ; YASUHARA, Y ; ISHINE, M ; KAWAMURA, M ; IIO, A ; HAMAMOTO, K</creator><creatorcontrib>MURASE, K ; KATAOKA, M ; YASUHARA, Y ; ISHINE, M ; KAWAMURA, M ; IIO, A ; HAMAMOTO, K</creatorcontrib><description>A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agreement with those obtained by the moments method was found within an error of several percent. In comparing with experiment and other Monte Carlo results, good agreement was also obtained within the range of statistical error. The absorbed dose rate for an 123I, 124I, 125I, 126I and 99mTc point source and their specific dose constants in various tissues and organs were calculated using this program. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be extended to various radionuclides used in nuclear medicine by adding their nuclear data to the program.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF00289020</identifier><identifier>PMID: 3622553</identifier><identifier>CODEN: EJNMD9</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Biological and medical sciences ; Computerized, statistical medical data processing and models in biomedicine ; General aspects. Methods ; Humans ; Iodine Radioisotopes ; Medical sciences ; Monte Carlo Method ; Radiation Dosage ; Radionuclide Imaging ; Software ; Technetium ; Tissue Distribution</subject><ispartof>European Journal Of Nuclear Medicine, 1987-01, Vol.13 (3), p.109-114</ispartof><rights>1988 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723</citedby><cites>FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&amp;idt=7394546$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/3622553$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>MURASE, K</creatorcontrib><creatorcontrib>KATAOKA, M</creatorcontrib><creatorcontrib>YASUHARA, Y</creatorcontrib><creatorcontrib>ISHINE, M</creatorcontrib><creatorcontrib>KAWAMURA, M</creatorcontrib><creatorcontrib>IIO, A</creatorcontrib><creatorcontrib>HAMAMOTO, K</creatorcontrib><title>Monte Carlo estimates of absorbed dose rate in various tissues and organs</title><title>European Journal Of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agreement with those obtained by the moments method was found within an error of several percent. In comparing with experiment and other Monte Carlo results, good agreement was also obtained within the range of statistical error. The absorbed dose rate for an 123I, 124I, 125I, 126I and 99mTc point source and their specific dose constants in various tissues and organs were calculated using this program. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be extended to various radionuclides used in nuclear medicine by adding their nuclear data to the program.</description><subject>Biological and medical sciences</subject><subject>Computerized, statistical medical data processing and models in biomedicine</subject><subject>General aspects. Methods</subject><subject>Humans</subject><subject>Iodine Radioisotopes</subject><subject>Medical sciences</subject><subject>Monte Carlo Method</subject><subject>Radiation Dosage</subject><subject>Radionuclide Imaging</subject><subject>Software</subject><subject>Technetium</subject><subject>Tissue Distribution</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1987</creationdate><recordtype>article</recordtype><recordid>eNpFkM1LAzEQxYMotVYv3oUcPAmrk-_NUYvVQsWLnpfsJpGVdlMyW8H_3kiLnubj_RjePEIuGdwyAHP3sADgtQUOR2TKNLOVgdoekykICZW21pySM8RPAJBSqAmZCM25UmJKli9pGAOdu7xONODYb9wYkKZIXYspt8FTnzDQXNa0H-iXy33aIR17xF0B3eBpyh9uwHNyEt0aw8Whzsj74vFt_lytXp-W8_tV1QnGxioqo5zySngIQukanPAhCi1lZzvGeQ2ca8Oi9CZyoV1ptWKsrT2U0XAxIzf7u11OiDnEZpuL6_zdMGh-42j-4yjw1R7e7tpN8H_o4f-iXx90h51bx-yGrsc_zAgrldTiByJeZRU</recordid><startdate>19870101</startdate><enddate>19870101</enddate><creator>MURASE, K</creator><creator>KATAOKA, M</creator><creator>YASUHARA, Y</creator><creator>ISHINE, M</creator><creator>KAWAMURA, M</creator><creator>IIO, A</creator><creator>HAMAMOTO, K</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>19870101</creationdate><title>Monte Carlo estimates of absorbed dose rate in various tissues and organs</title><author>MURASE, K ; KATAOKA, M ; YASUHARA, Y ; ISHINE, M ; KAWAMURA, M ; IIO, A ; HAMAMOTO, K</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1987</creationdate><topic>Biological and medical sciences</topic><topic>Computerized, statistical medical data processing and models in biomedicine</topic><topic>General aspects. Methods</topic><topic>Humans</topic><topic>Iodine Radioisotopes</topic><topic>Medical sciences</topic><topic>Monte Carlo Method</topic><topic>Radiation Dosage</topic><topic>Radionuclide Imaging</topic><topic>Software</topic><topic>Technetium</topic><topic>Tissue Distribution</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>MURASE, K</creatorcontrib><creatorcontrib>KATAOKA, M</creatorcontrib><creatorcontrib>YASUHARA, Y</creatorcontrib><creatorcontrib>ISHINE, M</creatorcontrib><creatorcontrib>KAWAMURA, M</creatorcontrib><creatorcontrib>IIO, A</creatorcontrib><creatorcontrib>HAMAMOTO, K</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><jtitle>European Journal Of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>MURASE, K</au><au>KATAOKA, M</au><au>YASUHARA, Y</au><au>ISHINE, M</au><au>KAWAMURA, M</au><au>IIO, A</au><au>HAMAMOTO, K</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Monte Carlo estimates of absorbed dose rate in various tissues and organs</atitle><jtitle>European Journal Of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1987-01-01</date><risdate>1987</risdate><volume>13</volume><issue>3</issue><spage>109</spage><epage>114</epage><pages>109-114</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><coden>EJNMD9</coden><abstract>A computer program based on the Monte Carlo technique was developed for calculation of absorbed dose rate in various tissues and organs. The accuracy of the program was tested by reproducing Berger's values of the specific absorbed fractions for point isotropic sources in water, and a good agreement with those obtained by the moments method was found within an error of several percent. In comparing with experiment and other Monte Carlo results, good agreement was also obtained within the range of statistical error. The absorbed dose rate for an 123I, 124I, 125I, 126I and 99mTc point source and their specific dose constants in various tissues and organs were calculated using this program. This computer program has the mass energy absorption and attenuation coefficients for 69 tissues and organs as a database file, and can be extended to various radionuclides used in nuclear medicine by adding their nuclear data to the program.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>3622553</pmid><doi>10.1007/BF00289020</doi><tpages>6</tpages></addata></record>
fulltext fulltext
identifier ISSN: 0340-6997
ispartof European Journal Of Nuclear Medicine, 1987-01, Vol.13 (3), p.109-114
issn 0340-6997
1619-7089
language eng
recordid cdi_crossref_primary_10_1007_BF00289020
source Alma/SFX Local Collection
subjects Biological and medical sciences
Computerized, statistical medical data processing and models in biomedicine
General aspects. Methods
Humans
Iodine Radioisotopes
Medical sciences
Monte Carlo Method
Radiation Dosage
Radionuclide Imaging
Software
Technetium
Tissue Distribution
title Monte Carlo estimates of absorbed dose rate in various tissues and organs
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-13T07%3A54%3A34IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-pubmed_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Monte%20Carlo%20estimates%20of%20absorbed%20dose%20rate%20in%20various%20tissues%20and%20organs&rft.jtitle=European%20Journal%20Of%20Nuclear%20Medicine&rft.au=MURASE,%20K&rft.date=1987-01-01&rft.volume=13&rft.issue=3&rft.spage=109&rft.epage=114&rft.pages=109-114&rft.issn=0340-6997&rft.eissn=1619-7089&rft.coden=EJNMD9&rft_id=info:doi/10.1007/BF00289020&rft_dat=%3Cpubmed_cross%3E3622553%3C/pubmed_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c311t-f575a5d53d0e35680a3def3644c9c1228022671f4d7f236a71f6511b8d0236723%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/3622553&rfr_iscdi=true