Loading…
Simultaneous measurement of left ventricular function and perfusion
A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first...
Saved in:
Published in: | European Journal of Nuclear Medicine 1990-06, Vol.17 (6-8), p.310-314 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383 |
---|---|
cites | cdi_FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383 |
container_end_page | 314 |
container_issue | 6-8 |
container_start_page | 310 |
container_title | European Journal of Nuclear Medicine |
container_volume | 17 |
creator | ELLIOTT, A. T MCKILLOP, J. H PRINGLE, S. D GILLEN, G. J WILSON, J. T LORIMER, A. R DARGIE, H. J |
description | A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly. |
doi_str_mv | 10.1007/BF01268021 |
format | article |
fullrecord | <record><control><sourceid>proquest_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1007_BF01268021</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>80254172</sourcerecordid><originalsourceid>FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383</originalsourceid><addsrcrecordid>eNpFkE1LxDAQhoMo67p68S70IB6E6kyaJs1RF1eFBQ_queQTKv1Yk0bw31vZojAwDO_Dy_AQco5wgwDi9n4DSHkFFA_IEjnKXEAlD8kSCgY5l1Ick5MYPwCAsaJckAWlFafAlmT92nSpHVXvhhSzzqmYgutcP2aDz1rnx-xrOkJjUqtC5lNvxmboM9XbbOeCT3G6TsmRV210Z_NekffNw9v6Kd--PD6v77a5KRDHXFqNzgmqlZWgLQovDRVcaDRlqSlXqKdh0gJ4o9B6qa2nnBnGnaVFVazI1b53F4bP5OJYd000rm3339eTgJKhoBN4vQdNGGIMzte70HQqfNcI9a-x-t_YBF_MrUl3zv6hs6Ipv5xzFY1qfVC9aeIfVjKKILD4AZanc28</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype><pqid>80254172</pqid></control><display><type>article</type><title>Simultaneous measurement of left ventricular function and perfusion</title><source>Alma/SFX Local Collection</source><creator>ELLIOTT, A. T ; MCKILLOP, J. H ; PRINGLE, S. D ; GILLEN, G. J ; WILSON, J. T ; LORIMER, A. R ; DARGIE, H. J</creator><creatorcontrib>ELLIOTT, A. T ; MCKILLOP, J. H ; PRINGLE, S. D ; GILLEN, G. J ; WILSON, J. T ; LORIMER, A. R ; DARGIE, H. J</creatorcontrib><description>A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly.</description><identifier>ISSN: 0340-6997</identifier><identifier>EISSN: 1619-7089</identifier><identifier>DOI: 10.1007/BF01268021</identifier><identifier>PMID: 2286204</identifier><identifier>CODEN: EJNMD9</identifier><language>eng</language><publisher>Berlin: Springer</publisher><subject>Adult ; Aged ; Biological and medical sciences ; Contrast Media ; Electrocardiography ; Exercise Test ; Heart - diagnostic imaging ; Humans ; Investigative techniques, diagnostic techniques (general aspects) ; Male ; Medical sciences ; Middle Aged ; Nitriles ; Organotechnetium Compounds ; Radionuclide investigations ; Technetium Tc 99m Sestamibi ; Tomography, Emission-Computed, Single-Photon ; Ventricular Function, Left - physiology ; Ventriculography, First-Pass</subject><ispartof>European Journal of Nuclear Medicine, 1990-06, Vol.17 (6-8), p.310-314</ispartof><rights>1992 INIST-CNRS</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383</citedby><cites>FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids><backlink>$$Uhttp://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=5421071$$DView record in Pascal Francis$$Hfree_for_read</backlink><backlink>$$Uhttps://www.ncbi.nlm.nih.gov/pubmed/2286204$$D View this record in MEDLINE/PubMed$$Hfree_for_read</backlink></links><search><creatorcontrib>ELLIOTT, A. T</creatorcontrib><creatorcontrib>MCKILLOP, J. H</creatorcontrib><creatorcontrib>PRINGLE, S. D</creatorcontrib><creatorcontrib>GILLEN, G. J</creatorcontrib><creatorcontrib>WILSON, J. T</creatorcontrib><creatorcontrib>LORIMER, A. R</creatorcontrib><creatorcontrib>DARGIE, H. J</creatorcontrib><title>Simultaneous measurement of left ventricular function and perfusion</title><title>European Journal of Nuclear Medicine</title><addtitle>Eur J Nucl Med</addtitle><description>A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly.</description><subject>Adult</subject><subject>Aged</subject><subject>Biological and medical sciences</subject><subject>Contrast Media</subject><subject>Electrocardiography</subject><subject>Exercise Test</subject><subject>Heart - diagnostic imaging</subject><subject>Humans</subject><subject>Investigative techniques, diagnostic techniques (general aspects)</subject><subject>Male</subject><subject>Medical sciences</subject><subject>Middle Aged</subject><subject>Nitriles</subject><subject>Organotechnetium Compounds</subject><subject>Radionuclide investigations</subject><subject>Technetium Tc 99m Sestamibi</subject><subject>Tomography, Emission-Computed, Single-Photon</subject><subject>Ventricular Function, Left - physiology</subject><subject>Ventriculography, First-Pass</subject><issn>0340-6997</issn><issn>1619-7089</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>1990</creationdate><recordtype>article</recordtype><recordid>eNpFkE1LxDAQhoMo67p68S70IB6E6kyaJs1RF1eFBQ_queQTKv1Yk0bw31vZojAwDO_Dy_AQco5wgwDi9n4DSHkFFA_IEjnKXEAlD8kSCgY5l1Ick5MYPwCAsaJckAWlFafAlmT92nSpHVXvhhSzzqmYgutcP2aDz1rnx-xrOkJjUqtC5lNvxmboM9XbbOeCT3G6TsmRV210Z_NekffNw9v6Kd--PD6v77a5KRDHXFqNzgmqlZWgLQovDRVcaDRlqSlXqKdh0gJ4o9B6qa2nnBnGnaVFVazI1b53F4bP5OJYd000rm3339eTgJKhoBN4vQdNGGIMzte70HQqfNcI9a-x-t_YBF_MrUl3zv6hs6Ipv5xzFY1qfVC9aeIfVjKKILD4AZanc28</recordid><startdate>199006</startdate><enddate>199006</enddate><creator>ELLIOTT, A. T</creator><creator>MCKILLOP, J. H</creator><creator>PRINGLE, S. D</creator><creator>GILLEN, G. J</creator><creator>WILSON, J. T</creator><creator>LORIMER, A. R</creator><creator>DARGIE, H. J</creator><general>Springer</general><scope>IQODW</scope><scope>CGR</scope><scope>CUY</scope><scope>CVF</scope><scope>ECM</scope><scope>EIF</scope><scope>NPM</scope><scope>AAYXX</scope><scope>CITATION</scope><scope>7X8</scope></search><sort><creationdate>199006</creationdate><title>Simultaneous measurement of left ventricular function and perfusion</title><author>ELLIOTT, A. T ; MCKILLOP, J. H ; PRINGLE, S. D ; GILLEN, G. J ; WILSON, J. T ; LORIMER, A. R ; DARGIE, H. J</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>1990</creationdate><topic>Adult</topic><topic>Aged</topic><topic>Biological and medical sciences</topic><topic>Contrast Media</topic><topic>Electrocardiography</topic><topic>Exercise Test</topic><topic>Heart - diagnostic imaging</topic><topic>Humans</topic><topic>Investigative techniques, diagnostic techniques (general aspects)</topic><topic>Male</topic><topic>Medical sciences</topic><topic>Middle Aged</topic><topic>Nitriles</topic><topic>Organotechnetium Compounds</topic><topic>Radionuclide investigations</topic><topic>Technetium Tc 99m Sestamibi</topic><topic>Tomography, Emission-Computed, Single-Photon</topic><topic>Ventricular Function, Left - physiology</topic><topic>Ventriculography, First-Pass</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>ELLIOTT, A. T</creatorcontrib><creatorcontrib>MCKILLOP, J. H</creatorcontrib><creatorcontrib>PRINGLE, S. D</creatorcontrib><creatorcontrib>GILLEN, G. J</creatorcontrib><creatorcontrib>WILSON, J. T</creatorcontrib><creatorcontrib>LORIMER, A. R</creatorcontrib><creatorcontrib>DARGIE, H. J</creatorcontrib><collection>Pascal-Francis</collection><collection>Medline</collection><collection>MEDLINE</collection><collection>MEDLINE (Ovid)</collection><collection>MEDLINE</collection><collection>MEDLINE</collection><collection>PubMed</collection><collection>CrossRef</collection><collection>MEDLINE - Academic</collection><jtitle>European Journal of Nuclear Medicine</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>ELLIOTT, A. T</au><au>MCKILLOP, J. H</au><au>PRINGLE, S. D</au><au>GILLEN, G. J</au><au>WILSON, J. T</au><au>LORIMER, A. R</au><au>DARGIE, H. J</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Simultaneous measurement of left ventricular function and perfusion</atitle><jtitle>European Journal of Nuclear Medicine</jtitle><addtitle>Eur J Nucl Med</addtitle><date>1990-06</date><risdate>1990</risdate><volume>17</volume><issue>6-8</issue><spage>310</spage><epage>314</epage><pages>310-314</pages><issn>0340-6997</issn><eissn>1619-7089</eissn><coden>EJNMD9</coden><abstract>A new radiopharmaceutical, methylisobutyl isonitrile (MIBI), has been developed as a technetium-99m-labelled alternative to thallium 201 for myocardial imaging. By virtue of the high specific activity of 99mTc, some 600 MBq may be administered as a 0.3 ml bolus, permitting the acquisition of a first-pass nuclear angiogram at rest and at peak exercise. The agent was assessed in ten sequential patients referred for routine cardiac catheterisation, who also underwent an exercise electrocardiographic (ECG) test. Good quality nuclear angiograms, planar perfusion and tomographic perfusion images were obtained; the results correlated well with the catheterisation data. Of 30 myocardial segments for which wall motion was judged normal/abnormal from the nuclear angiogram, results concordant with contrast studies were obtained in 27 (90%). In the case of the 50 segments analysed from the perfusion images, concordant results were obtained in 43 (86%) from the planar studies and in 42 (84%) from the tomographic studies. All normal segments were classified correctly.</abstract><cop>Berlin</cop><pub>Springer</pub><pmid>2286204</pmid><doi>10.1007/BF01268021</doi><tpages>5</tpages></addata></record> |
fulltext | fulltext |
identifier | ISSN: 0340-6997 |
ispartof | European Journal of Nuclear Medicine, 1990-06, Vol.17 (6-8), p.310-314 |
issn | 0340-6997 1619-7089 |
language | eng |
recordid | cdi_crossref_primary_10_1007_BF01268021 |
source | Alma/SFX Local Collection |
subjects | Adult Aged Biological and medical sciences Contrast Media Electrocardiography Exercise Test Heart - diagnostic imaging Humans Investigative techniques, diagnostic techniques (general aspects) Male Medical sciences Middle Aged Nitriles Organotechnetium Compounds Radionuclide investigations Technetium Tc 99m Sestamibi Tomography, Emission-Computed, Single-Photon Ventricular Function, Left - physiology Ventriculography, First-Pass |
title | Simultaneous measurement of left ventricular function and perfusion |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-27T20%3A32%3A05IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-proquest_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Simultaneous%20measurement%20of%20left%20ventricular%20function%20and%20perfusion&rft.jtitle=European%20Journal%20of%20Nuclear%20Medicine&rft.au=ELLIOTT,%20A.%20T&rft.date=1990-06&rft.volume=17&rft.issue=6-8&rft.spage=310&rft.epage=314&rft.pages=310-314&rft.issn=0340-6997&rft.eissn=1619-7089&rft.coden=EJNMD9&rft_id=info:doi/10.1007/BF01268021&rft_dat=%3Cproquest_cross%3E80254172%3C/proquest_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c311t-9db1ee72bad90bd17f9c2767b1c55b26a1ba1b49d00fca1df9bdf264c46ed2383%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_pqid=80254172&rft_id=info:pmid/2286204&rfr_iscdi=true |