The history and development of a rigorous metrological basis for pH measurements

This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapi...

Full description

Saved in:
Bibliographic Details
Published in:Journal of solid state electrochemistry 2011, Vol.15 (1), p.69-76
Main Authors: Spitzer, Petra, Pratt, Kenneth W.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33
cites cdi_FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33
container_end_page 76
container_issue 1
container_start_page 69
container_title Journal of solid state electrochemistry
container_volume 15
creator Spitzer, Petra
Pratt, Kenneth W.
description This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapid result. However, the problems posed by the traceability of pH are not easy to solve. Most pH measurements are performed by potentiometry, using a glass electrode as the pH sensor. Such pH electrodes must be calibrated at regular intervals. Confidence in the reliability of pH measurements requires establishment of a metrological hierarchy including an uncertainty budget for calibration that links the pH measured in the sample to an internationally agreed and stated reference. For pH, this reference is the primary measurement of pH. A traceability chain can be established that links field measurements of pH to primary buffer solutions that are certified using this primary method. This allows the user in the field to estimate the measurement uncertainty of the measured pH data. As the realization of the primary measurement is sophisticated and time-consuming, primary standards are generally realized at national metrology institutes. A number of potentiometric methods are suitable for the determination of the pH of reference buffer solutions by comparison with the primary standard buffers. The choice between the methods should be made according to the uncertainty required for the application. For reference buffer solutions that have the same nominal composition as the primary standard, the differential potentiometric cell, often called the Baucke cell, is recommended.
doi_str_mv 10.1007/s10008-010-1106-9
format article
fullrecord <record><control><sourceid>crossref_sprin</sourceid><recordid>TN_cdi_crossref_primary_10_1007_s10008_010_1106_9</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><sourcerecordid>10_1007_s10008_010_1106_9</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33</originalsourceid><addsrcrecordid>eNp9kMFOwzAMhiMEEmPwANzyAgG7rVL3iCZgSJPgMM5R2qRbp66Z4hZpb0_GOO9g-7fsz7J-IR4RnhCgfOaUgRQgKETQqroSMyzyXEGp6fpPZ4oKoltxx7wDwFIjzMTXeuvltuMxxKO0g5PO__g-HPZ-GGVopZWx24QYJpZ7P8bQh03X2F7WljuWbYjysEwTy1P0J4bvxU1re_YP_3Uuvt9e14ulWn2-fyxeVqrJiEZltYU8ayssEZzT0HrQNWaFS5HVBbmckIh8ARrrCsrGWVuj16QdQOHzfC7wfLeJgTn61hxit7fxaBDMyRJztsTAqU-WmCox2ZnhtDtsfDS7MMUhvXkB-gWh6GQU</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>The history and development of a rigorous metrological basis for pH measurements</title><source>Springer Link</source><creator>Spitzer, Petra ; Pratt, Kenneth W.</creator><creatorcontrib>Spitzer, Petra ; Pratt, Kenneth W.</creatorcontrib><description>This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapid result. However, the problems posed by the traceability of pH are not easy to solve. Most pH measurements are performed by potentiometry, using a glass electrode as the pH sensor. Such pH electrodes must be calibrated at regular intervals. Confidence in the reliability of pH measurements requires establishment of a metrological hierarchy including an uncertainty budget for calibration that links the pH measured in the sample to an internationally agreed and stated reference. For pH, this reference is the primary measurement of pH. A traceability chain can be established that links field measurements of pH to primary buffer solutions that are certified using this primary method. This allows the user in the field to estimate the measurement uncertainty of the measured pH data. As the realization of the primary measurement is sophisticated and time-consuming, primary standards are generally realized at national metrology institutes. A number of potentiometric methods are suitable for the determination of the pH of reference buffer solutions by comparison with the primary standard buffers. The choice between the methods should be made according to the uncertainty required for the application. For reference buffer solutions that have the same nominal composition as the primary standard, the differential potentiometric cell, often called the Baucke cell, is recommended.</description><identifier>ISSN: 1432-8488</identifier><identifier>EISSN: 1433-0768</identifier><identifier>DOI: 10.1007/s10008-010-1106-9</identifier><language>eng</language><publisher>Berlin/Heidelberg: Springer-Verlag</publisher><subject>Analytical Chemistry ; Characterization and Evaluation of Materials ; Chemistry ; Chemistry and Materials Science ; Condensed Matter Physics ; Electrochemistry ; Energy Storage ; Physical Chemistry ; Review</subject><ispartof>Journal of solid state electrochemistry, 2011, Vol.15 (1), p.69-76</ispartof><rights>Springer-Verlag 2010</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33</citedby><cites>FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Spitzer, Petra</creatorcontrib><creatorcontrib>Pratt, Kenneth W.</creatorcontrib><title>The history and development of a rigorous metrological basis for pH measurements</title><title>Journal of solid state electrochemistry</title><addtitle>J Solid State Electrochem</addtitle><description>This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapid result. However, the problems posed by the traceability of pH are not easy to solve. Most pH measurements are performed by potentiometry, using a glass electrode as the pH sensor. Such pH electrodes must be calibrated at regular intervals. Confidence in the reliability of pH measurements requires establishment of a metrological hierarchy including an uncertainty budget for calibration that links the pH measured in the sample to an internationally agreed and stated reference. For pH, this reference is the primary measurement of pH. A traceability chain can be established that links field measurements of pH to primary buffer solutions that are certified using this primary method. This allows the user in the field to estimate the measurement uncertainty of the measured pH data. As the realization of the primary measurement is sophisticated and time-consuming, primary standards are generally realized at national metrology institutes. A number of potentiometric methods are suitable for the determination of the pH of reference buffer solutions by comparison with the primary standard buffers. The choice between the methods should be made according to the uncertainty required for the application. For reference buffer solutions that have the same nominal composition as the primary standard, the differential potentiometric cell, often called the Baucke cell, is recommended.</description><subject>Analytical Chemistry</subject><subject>Characterization and Evaluation of Materials</subject><subject>Chemistry</subject><subject>Chemistry and Materials Science</subject><subject>Condensed Matter Physics</subject><subject>Electrochemistry</subject><subject>Energy Storage</subject><subject>Physical Chemistry</subject><subject>Review</subject><issn>1432-8488</issn><issn>1433-0768</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2011</creationdate><recordtype>article</recordtype><recordid>eNp9kMFOwzAMhiMEEmPwANzyAgG7rVL3iCZgSJPgMM5R2qRbp66Z4hZpb0_GOO9g-7fsz7J-IR4RnhCgfOaUgRQgKETQqroSMyzyXEGp6fpPZ4oKoltxx7wDwFIjzMTXeuvltuMxxKO0g5PO__g-HPZ-GGVopZWx24QYJpZ7P8bQh03X2F7WljuWbYjysEwTy1P0J4bvxU1re_YP_3Uuvt9e14ulWn2-fyxeVqrJiEZltYU8ayssEZzT0HrQNWaFS5HVBbmckIh8ARrrCsrGWVuj16QdQOHzfC7wfLeJgTn61hxit7fxaBDMyRJztsTAqU-WmCox2ZnhtDtsfDS7MMUhvXkB-gWh6GQU</recordid><startdate>2011</startdate><enddate>2011</enddate><creator>Spitzer, Petra</creator><creator>Pratt, Kenneth W.</creator><general>Springer-Verlag</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>2011</creationdate><title>The history and development of a rigorous metrological basis for pH measurements</title><author>Spitzer, Petra ; Pratt, Kenneth W.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2011</creationdate><topic>Analytical Chemistry</topic><topic>Characterization and Evaluation of Materials</topic><topic>Chemistry</topic><topic>Chemistry and Materials Science</topic><topic>Condensed Matter Physics</topic><topic>Electrochemistry</topic><topic>Energy Storage</topic><topic>Physical Chemistry</topic><topic>Review</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Spitzer, Petra</creatorcontrib><creatorcontrib>Pratt, Kenneth W.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of solid state electrochemistry</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Spitzer, Petra</au><au>Pratt, Kenneth W.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>The history and development of a rigorous metrological basis for pH measurements</atitle><jtitle>Journal of solid state electrochemistry</jtitle><stitle>J Solid State Electrochem</stitle><date>2011</date><risdate>2011</risdate><volume>15</volume><issue>1</issue><spage>69</spage><epage>76</epage><pages>69-76</pages><issn>1432-8488</issn><eissn>1433-0768</eissn><abstract>This paper discusses the basis and historical development of the traceability chain for pH. The quantity pH, first introduced in 1909, is among the most frequently measured analytical quantities. The practical measurement of the pH value of a sample is inexpensive, easy to perform, and yields a rapid result. However, the problems posed by the traceability of pH are not easy to solve. Most pH measurements are performed by potentiometry, using a glass electrode as the pH sensor. Such pH electrodes must be calibrated at regular intervals. Confidence in the reliability of pH measurements requires establishment of a metrological hierarchy including an uncertainty budget for calibration that links the pH measured in the sample to an internationally agreed and stated reference. For pH, this reference is the primary measurement of pH. A traceability chain can be established that links field measurements of pH to primary buffer solutions that are certified using this primary method. This allows the user in the field to estimate the measurement uncertainty of the measured pH data. As the realization of the primary measurement is sophisticated and time-consuming, primary standards are generally realized at national metrology institutes. A number of potentiometric methods are suitable for the determination of the pH of reference buffer solutions by comparison with the primary standard buffers. The choice between the methods should be made according to the uncertainty required for the application. For reference buffer solutions that have the same nominal composition as the primary standard, the differential potentiometric cell, often called the Baucke cell, is recommended.</abstract><cop>Berlin/Heidelberg</cop><pub>Springer-Verlag</pub><doi>10.1007/s10008-010-1106-9</doi><tpages>8</tpages></addata></record>
fulltext fulltext
identifier ISSN: 1432-8488
ispartof Journal of solid state electrochemistry, 2011, Vol.15 (1), p.69-76
issn 1432-8488
1433-0768
language eng
recordid cdi_crossref_primary_10_1007_s10008_010_1106_9
source Springer Link
subjects Analytical Chemistry
Characterization and Evaluation of Materials
Chemistry
Chemistry and Materials Science
Condensed Matter Physics
Electrochemistry
Energy Storage
Physical Chemistry
Review
title The history and development of a rigorous metrological basis for pH measurements
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T08%3A33%3A37IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-crossref_sprin&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=The%20history%20and%20development%20of%20a%20rigorous%20metrological%20basis%20for%20pH%20measurements&rft.jtitle=Journal%20of%20solid%20state%20electrochemistry&rft.au=Spitzer,%20Petra&rft.date=2011&rft.volume=15&rft.issue=1&rft.spage=69&rft.epage=76&rft.pages=69-76&rft.issn=1432-8488&rft.eissn=1433-0768&rft_id=info:doi/10.1007/s10008-010-1106-9&rft_dat=%3Ccrossref_sprin%3E10_1007_s10008_010_1106_9%3C/crossref_sprin%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-a6a032f91710dd60fe06b124d1242b48d381888e4061b907cdaab1e686d004e33%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true