Loading…
Sulfur modified with 2-mercaptobenzoxazole as a new sorbent for preconcentration of silver prior to determination by flame atomic absorption spectrometry
A solid-phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the retention of silver on sulfur modified with 2-mercaptobenzoxazole. The retained silver is eluted from the column with a thiourea solu...
Saved in:
Published in: | Journal of the Iranian Chemical Society 2013-04, Vol.10 (2), p.319-324 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | A solid-phase extraction method for preconcentration of silver and consequent determination by atomic absorption spectrometry is described. The method is based on the retention of silver on sulfur modified with 2-mercaptobenzoxazole. The retained silver is eluted from the column with a thiourea solution and determined by flame atomic absorption spectrometry. The preconcentration conditions such as pH, amount of reagent loaded on sorbent, type of eluent and its volume, flow rate and interfering ions were investigated. The calibration graph was linear in the range of 3–200 ng mL
−1
of Ag
+
in the initial solution with
r
= 0.9985. The limit of detection based on 3S
b
was 1.0 ng mL
−1
. The relative standard deviation for ten replicate measurements of 50 and 150 ng mL
−1
of Ag
+
was 4.1 and 1.4 %, respectively. The method was applied to the determination of silver in radiology film and water samples. |
---|---|
ISSN: | 1735-207X 1735-2428 |
DOI: | 10.1007/s13738-012-0161-9 |