Monitoring the effluents of the trichloroacetic acid process by high-performance liquid chromatography

A simple and rapid high-performance liquid chromatographic method for the simultaneous determination of small amounts of nitric acid and trichloroacetic acid in process effluents was developed. Acidic components of the effluents were separated on a reversed-phase C 18 column using 0.15 M ammonium su...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 1992-05, Vol.600 (2), p.316-319
Main Authors: Husain, Sajid, Narsimha, R., Alvi, S.N., Rao, R.Nageswara
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simple and rapid high-performance liquid chromatographic method for the simultaneous determination of small amounts of nitric acid and trichloroacetic acid in process effluents was developed. Acidic components of the effluents were separated on a reversed-phase C 18 column using 0.15 M ammonium sulphate as mobile phase and determined quantitatively by UV absorption at 210 nm. The detection limits for nitric acid and trichloroacetic acid were 1.4 and 10 μg/l, respectively.