Loading…

Iodometric microdetermination of semicarbazide by amplification reactions

An analytical method for the determination of 10–2000 μg of semicarbazide is described, using titrimetric procedure with an amplification reaction. It relies upon the reaction of semicarbazide, in phosphate-buffer (pH 7) solution, with a chloroform solution of iodine, and removal of its excess; oxid...

Full description

Saved in:
Bibliographic Details
Published in:Microchemical journal 1983, Vol.28 (3), p.325-327
Main Authors: Amin, D., Abeed, F.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:An analytical method for the determination of 10–2000 μg of semicarbazide is described, using titrimetric procedure with an amplification reaction. It relies upon the reaction of semicarbazide, in phosphate-buffer (pH 7) solution, with a chloroform solution of iodine, and removal of its excess; oxidation of the iodide formed with bromine; and determination of the liberated iodate by the Leipert amplification procedure. The recovery ranged from 97.0 to 100.1%.
ISSN:0026-265X
1095-9149