Wear in external gear pumps: A simplified model
Wear in external gear pumps, as used in hydraulic systems, is not uniformly distributed over the sliding surfaces. It is confirmed that wear occurs at regions of close clearance. Flow between these surfaces is complex, and existing fundamental wear models are not satisfactory. A proposal is given to...
Saved in:
Published in: | Wear 1994-03, Vol.172 (2), p.121-126 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Wear in external gear pumps, as used in hydraulic systems, is not uniformly distributed over the sliding surfaces. It is confirmed that wear occurs at regions of close clearance. Flow between these surfaces is complex, and existing fundamental wear models are not satisfactory. A proposal is given to aid the evolution of fundamental wear modelling as applied to an actual external gear pump. The approach taken is simple but does give surprisingly good correlation with experimental results. Direction is given for further research. |
---|---|