Magnetic field measurements of the harmonic generation FEL superconducting undulator at BNL-NSLS

A three stage superconducting undulator (modulator, dispersive section, and radiator) is under construction at Brookhaven National Laboratory. Sections of the radiator, consisting of 25 cm long steel yokes, each with 18 mm period, 0.54 T field, and 8.6 mm gap are under test. The magnetic measurement...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1995-04, Vol.358 (1-3), p.411-413
Main Authors: Solomon, L., Graves, W.S., Lehrman, I.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A three stage superconducting undulator (modulator, dispersive section, and radiator) is under construction at Brookhaven National Laboratory. Sections of the radiator, consisting of 25 cm long steel yokes, each with 18 mm period, 0.54 T field, and 8.6 mm gap are under test. The magnetic measurements and operational characteristics of the magnet are discussed. Measurement results and analyses are presented, with emphasis on the integrated field quality. The magnet winding and the effects of the various trims are discussed.