Loading…

Drop size in a liquid—liquid dispersion: Formation in jet Break-up

Using a photographic technique, the mean drop size of densely packed liquid-liquid dispersions has been measured in a spray column. For each pair of flow rates a gaussian distribution has been obtained; a correlation predicting the mean size is proposed, the drops resulting from break up of jets for...

Full description

Saved in:
Bibliographic Details
Published in:The Chemical engineering journal 1972, Vol.3, p.286-293
Main Authors: Perrut, M., Loutaty, R.
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Using a photographic technique, the mean drop size of densely packed liquid-liquid dispersions has been measured in a spray column. For each pair of flow rates a gaussian distribution has been obtained; a correlation predicting the mean size is proposed, the drops resulting from break up of jets formed with perforated plates. For fifteen liquid-liquid systems investigated the ratio of the mean drop size d̄ to the diameter of the injector perforations φ is linearly related to Eötvös number Δϱφ 2/σ.
ISSN:0300-9467
1873-5541
DOI:10.1016/0300-9467(72)85032-9