Performance of valve-regulated lead/acid test cells for float operation using modified positive active materials
Three types of valve-regulated lead/acid cells have been made with positive active material prepared from: (i) tribasic lead sulfate; (ii) tetrabasic lead sulfate; (iii) tetrabasic lead sulfate with graphite added. The cells have been subjected to float operation. They undergo premature capacity los...
Saved in:
Published in: | Journal of power sources 1995, Vol.53 (1), p.119-125 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | Three types of valve-regulated lead/acid cells have been made with positive active material prepared from: (i) tribasic lead sulfate; (ii) tetrabasic lead sulfate; (iii) tetrabasic lead sulfate with graphite added. The cells have been subjected to float operation. They undergo premature capacity loss. The circumstances of this effect, the possibility of recovery of the capacity, the role of the graphite, and the impedance spectra of the cells are discussed. |
---|---|
ISSN: | 0378-7753 1873-2755 |
DOI: | 10.1016/0378-7753(94)02160-5 |