Statement of problem A key factor of a successful facial prosthesis is the retention of the prosthesis to the patient's skin, especially when there is no mechanical means and the retention depends primarily on medical skin adhesives. Studies determining which medical adhesives provide the best...

Full description

Saved in:
Bibliographic Details
Published in:The Journal of prosthetic dentistry 2008-06, Vol.99 (6), p.483-488
Main Authors: Kiat-amnuay, Sudarat, MS, DDS, Waters, Patrick J, Roberts, Dianna, PhD, Gettleman, Lawrence, MSD, DMD
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:Statement of problem A key factor of a successful facial prosthesis is the retention of the prosthesis to the patient's skin, especially when there is no mechanical means and the retention depends primarily on medical skin adhesives. Studies determining which medical adhesives provide the best bond strength for maxillofacial prostheses are needed. Purpose The purpose of this study was to quantify the force required to detach strips of Silastic Adhesive A/MDX4-4210 silicone elastomer with a urethane liner (A/M-U) and experimental chlorinated polyethylene elastomer (CPE) from the skin of human subjects coated with a protective dressing using 1 of 2 medical adhesives. Material and methods With IRB approval, 8 A/M-U and CPE rubber strips (total of 208) were applied in a predetermined random order to the left and right ventral forearms of 26 human subjects. Skin-Prep Protective Dressing (SP) was applied to half of the sites just before Epithane-3 (E3) and Secure Medical Adhesive (SMA) were used to adhere the strips. Strips were peeled 6 hours later in a universal testing machine at 10 cm/min. Data are reported in newton/meter (N/m). The data was compared using a 3-way, within-groups, multivariate analysis of variance (MANOVA) and the Fisher exact test (α=.05). Values for N/m under various conditions relating to the subjects were compared by the Tukey HSD Test for unequal N (α=.05). Data are reported as mean (SD). Results Statistical analysis revealed no differences (mean (SD)) and no significant interactions between the independent variables (A/M-U = 94.6 (62.1) and CPE = 98.4 (69.6) N/m, SP = 93.0 (58.8) and no SP = 99.8 (72.1) N/m, E3 = 97.6 (69.8) and SMA = 95.3 (61.8) N/m; P =.984). Debonding occurred at the skin interface for both adhesives, as evidenced by residue on prosthetic materials (Fisher exact test; P
ISSN:0022-3913
1097-6841
DOI:10.1016/S0022-3913(08)60113-4