Commissioning Results of the BTUC-PGM beamline
The CRG beamline was commissioned in June 2000. This paper presents the results of the first resolution and flux measurements. The monochromator resolution was evaluated using gas cell absorbtion measurements for argon, nitrogen and neon. The results of the nitrogen measurements demonstrate a resolv...
Saved in:
Published in: | Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2001-07, Vol.467, p.470-473 |
---|---|
Main Authors: | , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The CRG beamline was commissioned in June 2000. This paper presents the results of the first resolution and flux measurements. The monochromator resolution was evaluated using gas cell absorbtion measurements for argon, nitrogen and neon. The results of the nitrogen measurements demonstrate a resolving power of 10,000. The monochromator flux measurements were made using a GaAs diode and show that the beamline can deliver 10
13 photons
s
−1 at 100
eV for a 140
μm exit slit. |
---|---|