Loading…

Studies of aging and HV break down problems during development and operation of MSGC and GEM detectors for the inner tracking system of HERA-B

The results of 5 years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about (20×20) cm 2 each. The detector is based on microstrip gas...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 2002-09, Vol.490 (1), p.223-242
Main Authors: Bagaturia, Y, Baruth, O, Dreis, H.B, Eisele, F, Gorbunov, I, Gradl, S, Gradl, W, Hausmann, S, Hildebrandt, M, Hott, T, Keller, S, Krauss, C, Lomonosov, B, Negodaev, M, Richter, C, Robmann, P, Schmidt, B, Straumann, U, Truöl, P, Visbeck, S, Walter, T, Werner, C, Werthenbach, U, Zech, G, Zeuner, T, Ziegler, M
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The results of 5 years of development of the inner tracking system of the HERA-B experiment and first experience from the data taking period of the year 2000 are reported. The system contains 184 chambers, covering a sensitive area of about (20×20) cm 2 each. The detector is based on microstrip gas counters (MSGCs) with diamond-like coated (DLC) glass wafers and gas electron multipliers (GEMs). The main problems in the development phase were gas discharges in intense hadron beams and aging in a high radiation dose environment. The observation of gas discharges which damage the electrode structure of the MSGC led to the addition of the GEM as a first amplification step. Spurious sparking at the GEM cannot be avoided completely. It does not affect the GEM itself but can produce secondary damage of the MSGC if the electric field between the GEM and the MSGC is above a threshold depending on the operation conditions. We observed that aging does not only depend on the dose but also on the spot size of the irradiated area. Ar–DME mixtures had to be abandoned whereas a mixture of 70% Ar and 30% CO 2 showed no serious aging effects up to about 40 mC /cm deposited charge on the anodes. X-ray measurements indicate that the DLC of the MSGC is deteriorated by the gas amplification process. As a consequence, long-term gain variations are expected. The Inner Tracker has successfully participated in the data taking at HERA-B during summer 2000.
ISSN:0168-9002
1872-9576
DOI:10.1016/S0168-9002(02)01002-1