Loading…

Short- and long-range penetration of fields and potentials through meshes, grids or gauzes

When a conducting partially-transparent mesh is used to separate two regions of different electrostatic field strength there are short-range changes to the field and potential distributions in the vicinity of the mesh and also long-range changes far from the mesh. The forms and magnitudes of these c...

Full description

Saved in:
Bibliographic Details
Published in:Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment Accelerators, spectrometers, detectors and associated equipment, 1999, Vol.427 (1), p.363-367
Main Authors: Read, F.H, Bowring, N.J, Bullivant, P.D, Ward, R.R.A
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:When a conducting partially-transparent mesh is used to separate two regions of different electrostatic field strength there are short-range changes to the field and potential distributions in the vicinity of the mesh and also long-range changes far from the mesh. The forms and magnitudes of these changes are investigated computationally for meshes that consist of parallel or crossed round wires or crossed flat strips.
ISSN:0168-9002
1872-9576
DOI:10.1016/S0168-9002(98)01564-2