Loading…

New electron-capture gas-liquid chromatographic method for the determination of mexiletine plasma levels in man

A method for the determination of mexiletine in human plasma by gas—liquid chromatography with electron-capture detection is described. Plasma samples are extracted at pH 12 with dichloromethane after addition of the internal standard, the 2,4-methyl analogue of mexiletine. A derivative is obtained...

Full description

Saved in:
Bibliographic Details
Published in:Journal of chromatography. Biomedical applications 1978-05, Vol.145 (3), p.401-411
Main Authors: Frydman, Armand, Lafarge, Jean-Pierre, Vial, François, Rulliere, Roger, Alexandre, Jean-Michel
Format: Article
Language:English
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A method for the determination of mexiletine in human plasma by gas—liquid chromatography with electron-capture detection is described. Plasma samples are extracted at pH 12 with dichloromethane after addition of the internal standard, the 2,4-methyl analogue of mexiletine. A derivative is obtained using heptafluorobutyric anhydride; according to gas chromatography—mass spectrometry it is a monoheptafluorobutyryl compound. The minimum detectable amount of mexiletine is 5 pg. Accurate determinations of human plasma levels were performed after oral or intravenous treatment.
ISSN:0378-4347