Micronozzle/diffuser flow and its application in micro valveless pumps

The nozzle/diffuser flow with different Reynolds number ranges and conical angles is analyzed first. It is found that the flow coefficients of nozzle/diffuser ξ n and ξ d vary with angle with different trends for large (> 10 5) and small (

Saved in:
Bibliographic Details
Published in:Sensors and actuators. A. Physical. 1998-10, Vol.70 (1), p.81-87
Main Authors: Jiang, X.N., Zhou, Z.Y., Huang, X.Y., Li, Y., Yang, Y., Liu, C.Y.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The nozzle/diffuser flow with different Reynolds number ranges and conical angles is analyzed first. It is found that the flow coefficients of nozzle/diffuser ξ n and ξ d vary with angle with different trends for large (> 10 5) and small (