Loading…
Development and evaluation of a kit formulation for the preparation of 99mTc-DMP-HSA, a new tracer agent for radionuclide ventriculography
This study presents the development of a kit formulation for the preparation of 99mTc-DMP-HSA, followed by a comparison of such kit-prepared 99mTc-DMP-HSA to 99mTc-RBCs in a volunteer. Reconstitution of the labeling kits with up to 5.55 GBq 99mTc afforded 99mTc-DMP-HSA preparations with a >95% ra...
Saved in:
Published in: | Nuclear medicine and biology 1997-08, Vol.24 (6), p.571-578 |
---|---|
Main Authors: | , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | This study presents the development of a kit formulation for the preparation of
99mTc-DMP-HSA, followed by a comparison of such kit-prepared
99mTc-DMP-HSA to
99mTc-RBCs in a volunteer. Reconstitution of the labeling kits with up to 5.55 GBq
99mTc afforded
99mTc-DMP-HSA preparations with a >95% radiochemical purity for up to 8 h. Only minor differences were observed in the global distribution of both tracer agents, whereas the calculated ejection fractions were almost identical. The effective dose equivalent of
99mTc-DMP-HSA is 8.68 μSv/MBq. |
---|---|
ISSN: | 0969-8051 1872-9614 |
DOI: | 10.1016/S0969-8051(97)00019-X |