Loading…

Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool

•The critical Ri values were determined for onset and minor temperature fluctuations related to thermal stratification.•The relationship between ascending speed of the thermal stratification interface and Pe was analyzed and fitted.•The dominant frequency of temperature fluctuation was identified th...

Full description

Saved in:
Bibliographic Details
Published in:Annals of nuclear energy 2025-02, Vol.211, p.110900, Article 110900
Main Authors: Li, Wenbo, Bai, Yunqing, Zhou, Danna, Li, Wendong, Yu, Dajian, Li, Yang
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c187t-2cfa5e47d7588ba91738fa78e91c383dcb0950e0d70d0ddec6a0a5d0a104bc53
container_end_page
container_issue
container_start_page 110900
container_title Annals of nuclear energy
container_volume 211
creator Li, Wenbo
Bai, Yunqing
Zhou, Danna
Li, Wendong
Yu, Dajian
Li, Yang
description •The critical Ri values were determined for onset and minor temperature fluctuations related to thermal stratification.•The relationship between ascending speed of the thermal stratification interface and Pe was analyzed and fitted.•The dominant frequency of temperature fluctuation was identified through power spectral density analysis. The thermal stratification in Lead-Based Reactors would pose a significant threat to safe operation. A numerical study is presented in this work to illustrate the effects of the Richardson number (Ri) and the Peclet number (Pe) on thermal stratification in a scaled-down hot pool of lead–bismuth eutectic (LBE). The results demonstrated the critical value of Ri for the emergence of thermal stratification was approximately 1. Moreover, when the flux Richardson number (Rif) was above 4, the temperature fluctuation at the thermal stratification interface was marginal. The interface ascending rate of thermal stratification was inversely proportional to Pe. Increasing Pe would intensify the temperature fluctuation. The dominant frequency of the temperature profile was 0.1 ∼ 1 Hz, implying a high possibility of thermal fatigue at the solid surface. The results of this work will be helpful for the design and optimization of thermohydraulic parameters in Lead-Based Reactors.
doi_str_mv 10.1016/j.anucene.2024.110900
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_anucene_2024_110900</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0306454924005632</els_id><sourcerecordid>S0306454924005632</sourcerecordid><originalsourceid>FETCH-LOGICAL-c187t-2cfa5e47d7588ba91738fa78e91c383dcb0950e0d70d0ddec6a0a5d0a104bc53</originalsourceid><addsrcrecordid>eNqFkMtOwzAQRb0AiVL4BCT_QMI4sRtnhaAqD6mCTfeWM56ortq4sl1Q_56Uds_qSjNzrkaHsQcBpQAxe9yUdjggDVRWUMlSCGgBrtgEapgVUsn2ht2mtAEQlZZywrrPw46iR7vlKR_ckYeB5zVxXNtoMY-rlD0mHvq_8fJlccq4-7uPNvt-ZLMfKT9wy9NYRK5w4Wfg65D5PoTtHbvu7TbR_SWnbPW6WM3fi-XX28f8eVmg0E0uKuytItm4Rmnd2VY0te5to6kVWOvaYQetAgLXgAPnCGcWrHJgBcgOVT1l6lyLMaQUqTf76Hc2Ho0Ac3JjNubixpzcmLObkXs6czT-9u0pmoSeBiTnI2E2Lvh_Gn4BZGBzgg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool</title><source>ScienceDirect Journals</source><creator>Li, Wenbo ; Bai, Yunqing ; Zhou, Danna ; Li, Wendong ; Yu, Dajian ; Li, Yang</creator><creatorcontrib>Li, Wenbo ; Bai, Yunqing ; Zhou, Danna ; Li, Wendong ; Yu, Dajian ; Li, Yang</creatorcontrib><description>•The critical Ri values were determined for onset and minor temperature fluctuations related to thermal stratification.•The relationship between ascending speed of the thermal stratification interface and Pe was analyzed and fitted.•The dominant frequency of temperature fluctuation was identified through power spectral density analysis. The thermal stratification in Lead-Based Reactors would pose a significant threat to safe operation. A numerical study is presented in this work to illustrate the effects of the Richardson number (Ri) and the Peclet number (Pe) on thermal stratification in a scaled-down hot pool of lead–bismuth eutectic (LBE). The results demonstrated the critical value of Ri for the emergence of thermal stratification was approximately 1. Moreover, when the flux Richardson number (Rif) was above 4, the temperature fluctuation at the thermal stratification interface was marginal. The interface ascending rate of thermal stratification was inversely proportional to Pe. Increasing Pe would intensify the temperature fluctuation. The dominant frequency of the temperature profile was 0.1 ∼ 1 Hz, implying a high possibility of thermal fatigue at the solid surface. The results of this work will be helpful for the design and optimization of thermohydraulic parameters in Lead-Based Reactors.</description><identifier>ISSN: 0306-4549</identifier><identifier>DOI: 10.1016/j.anucene.2024.110900</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Frequency analysis ; Lead-based reactors ; Temperature fluctuation ; Thermal stratification</subject><ispartof>Annals of nuclear energy, 2025-02, Vol.211, p.110900, Article 110900</ispartof><rights>2024 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c187t-2cfa5e47d7588ba91738fa78e91c383dcb0950e0d70d0ddec6a0a5d0a104bc53</cites></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27923,27924</link.rule.ids></links><search><creatorcontrib>Li, Wenbo</creatorcontrib><creatorcontrib>Bai, Yunqing</creatorcontrib><creatorcontrib>Zhou, Danna</creatorcontrib><creatorcontrib>Li, Wendong</creatorcontrib><creatorcontrib>Yu, Dajian</creatorcontrib><creatorcontrib>Li, Yang</creatorcontrib><title>Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool</title><title>Annals of nuclear energy</title><description>•The critical Ri values were determined for onset and minor temperature fluctuations related to thermal stratification.•The relationship between ascending speed of the thermal stratification interface and Pe was analyzed and fitted.•The dominant frequency of temperature fluctuation was identified through power spectral density analysis. The thermal stratification in Lead-Based Reactors would pose a significant threat to safe operation. A numerical study is presented in this work to illustrate the effects of the Richardson number (Ri) and the Peclet number (Pe) on thermal stratification in a scaled-down hot pool of lead–bismuth eutectic (LBE). The results demonstrated the critical value of Ri for the emergence of thermal stratification was approximately 1. Moreover, when the flux Richardson number (Rif) was above 4, the temperature fluctuation at the thermal stratification interface was marginal. The interface ascending rate of thermal stratification was inversely proportional to Pe. Increasing Pe would intensify the temperature fluctuation. The dominant frequency of the temperature profile was 0.1 ∼ 1 Hz, implying a high possibility of thermal fatigue at the solid surface. The results of this work will be helpful for the design and optimization of thermohydraulic parameters in Lead-Based Reactors.</description><subject>Frequency analysis</subject><subject>Lead-based reactors</subject><subject>Temperature fluctuation</subject><subject>Thermal stratification</subject><issn>0306-4549</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2025</creationdate><recordtype>article</recordtype><recordid>eNqFkMtOwzAQRb0AiVL4BCT_QMI4sRtnhaAqD6mCTfeWM56ortq4sl1Q_56Uds_qSjNzrkaHsQcBpQAxe9yUdjggDVRWUMlSCGgBrtgEapgVUsn2ht2mtAEQlZZywrrPw46iR7vlKR_ckYeB5zVxXNtoMY-rlD0mHvq_8fJlccq4-7uPNvt-ZLMfKT9wy9NYRK5w4Wfg65D5PoTtHbvu7TbR_SWnbPW6WM3fi-XX28f8eVmg0E0uKuytItm4Rmnd2VY0te5to6kVWOvaYQetAgLXgAPnCGcWrHJgBcgOVT1l6lyLMaQUqTf76Hc2Ho0Ac3JjNubixpzcmLObkXs6czT-9u0pmoSeBiTnI2E2Lvh_Gn4BZGBzgg</recordid><startdate>202502</startdate><enddate>202502</enddate><creator>Li, Wenbo</creator><creator>Bai, Yunqing</creator><creator>Zhou, Danna</creator><creator>Li, Wendong</creator><creator>Yu, Dajian</creator><creator>Li, Yang</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope></search><sort><creationdate>202502</creationdate><title>Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool</title><author>Li, Wenbo ; Bai, Yunqing ; Zhou, Danna ; Li, Wendong ; Yu, Dajian ; Li, Yang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c187t-2cfa5e47d7588ba91738fa78e91c383dcb0950e0d70d0ddec6a0a5d0a104bc53</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2025</creationdate><topic>Frequency analysis</topic><topic>Lead-based reactors</topic><topic>Temperature fluctuation</topic><topic>Thermal stratification</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Li, Wenbo</creatorcontrib><creatorcontrib>Bai, Yunqing</creatorcontrib><creatorcontrib>Zhou, Danna</creatorcontrib><creatorcontrib>Li, Wendong</creatorcontrib><creatorcontrib>Yu, Dajian</creatorcontrib><creatorcontrib>Li, Yang</creatorcontrib><collection>CrossRef</collection><jtitle>Annals of nuclear energy</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Li, Wenbo</au><au>Bai, Yunqing</au><au>Zhou, Danna</au><au>Li, Wendong</au><au>Yu, Dajian</au><au>Li, Yang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool</atitle><jtitle>Annals of nuclear energy</jtitle><date>2025-02</date><risdate>2025</risdate><volume>211</volume><spage>110900</spage><pages>110900-</pages><artnum>110900</artnum><issn>0306-4549</issn><abstract>•The critical Ri values were determined for onset and minor temperature fluctuations related to thermal stratification.•The relationship between ascending speed of the thermal stratification interface and Pe was analyzed and fitted.•The dominant frequency of temperature fluctuation was identified through power spectral density analysis. The thermal stratification in Lead-Based Reactors would pose a significant threat to safe operation. A numerical study is presented in this work to illustrate the effects of the Richardson number (Ri) and the Peclet number (Pe) on thermal stratification in a scaled-down hot pool of lead–bismuth eutectic (LBE). The results demonstrated the critical value of Ri for the emergence of thermal stratification was approximately 1. Moreover, when the flux Richardson number (Rif) was above 4, the temperature fluctuation at the thermal stratification interface was marginal. The interface ascending rate of thermal stratification was inversely proportional to Pe. Increasing Pe would intensify the temperature fluctuation. The dominant frequency of the temperature profile was 0.1 ∼ 1 Hz, implying a high possibility of thermal fatigue at the solid surface. The results of this work will be helpful for the design and optimization of thermohydraulic parameters in Lead-Based Reactors.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.anucene.2024.110900</doi></addata></record>
fulltext fulltext
identifier ISSN: 0306-4549
ispartof Annals of nuclear energy, 2025-02, Vol.211, p.110900, Article 110900
issn 0306-4549
language eng
recordid cdi_crossref_primary_10_1016_j_anucene_2024_110900
source ScienceDirect Journals
subjects Frequency analysis
Lead-based reactors
Temperature fluctuation
Thermal stratification
title Numerical study on the characteristics of the LBE thermal stratification in a scaled-down hot pool
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-09T06%3A19%3A43IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Numerical%20study%20on%20the%20characteristics%20of%20the%20LBE%20thermal%20stratification%20in%20a%20scaled-down%20hot%20pool&rft.jtitle=Annals%20of%20nuclear%20energy&rft.au=Li,%20Wenbo&rft.date=2025-02&rft.volume=211&rft.spage=110900&rft.pages=110900-&rft.artnum=110900&rft.issn=0306-4549&rft_id=info:doi/10.1016/j.anucene.2024.110900&rft_dat=%3Celsevier_cross%3ES0306454924005632%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c187t-2cfa5e47d7588ba91738fa78e91c383dcb0950e0d70d0ddec6a0a5d0a104bc53%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true