Loading…
Improved Aures tonality metric for complex sounds
•Aures’ method to estimate the tonality has been revisited.•An improved version of the original Aures model has been proposed and validated through subjective tests.•The improved Aures model of the tonality can accurately predict the masking threshold of complex sounds in presence of narrowband nois...
Saved in:
Published in: | Applied acoustics 2023-03, Vol.204, p.109238, Article 109238 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •Aures’ method to estimate the tonality has been revisited.•An improved version of the original Aures model has been proposed and validated through subjective tests.•The improved Aures model of the tonality can accurately predict the masking threshold of complex sounds in presence of narrowband noises.
This paper proposes improvements to the Aures’ tonality metric, which can be used for estimating the frequency masking of complex sounds. The perception of tonality has been extensively studied in simple sounds, such as pure tones and narrowband noise signals, but there are no solid conclusions in the case of complex sounds. Previously, Aures’ method has been mostly used in the psychoacoustic analysis of noise signals. The modifications presented here are a better spectral resolution, a lowered tonal threshold, and a different exponent in one of their weighting functions. These may appear to be minor changes from the original Aures (OA) method, but they have proven to be significant for perception. The improved Aures (IA) method has been validated by a subjective test using three different multitone signals in the presence of a narrowband noise, whose result is the subjectively perceived masking thresholds. Results show that the IA method presents an average error of 0.8 dB when predicting the subjective masking thresholds provided by the test, while the average errors of the OA and a baseline spectral flatness method exceed 5 dB. In addition, a second subjective test has been carried out to assess the perceptual equalization of a music signal using the proposed IA and spectral flatness methods. The second test confirms that the IA method is preferred. Therefore, the improved Aures method is proposed as a reliable tonality metric for complex sounds, such as multi-tone signals and music. |
---|---|
ISSN: | 0003-682X 1872-910X |
DOI: | 10.1016/j.apacoust.2023.109238 |