Loading…

Quantification of heat losses through building envelope thermal bridges influenced by wind velocity using the outdoor infrared thermography technique

•A method to assess thermal bridging heat loss using the outdoor ITT is developed.•The ITT approach is compared with hot box measurements and numerical predictions.•The wind velocity impact on thermal bridging is quantified.•Adjusting procedure for the Ψ-value measured at different wind velocities i...

Full description

Saved in:
Bibliographic Details
Published in:Applied energy 2017-12, Vol.208, p.1038-1052
Main Authors: O'Grady, Małgorzata, Lechowska, Agnieszka A., Harte, Annette M.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•A method to assess thermal bridging heat loss using the outdoor ITT is developed.•The ITT approach is compared with hot box measurements and numerical predictions.•The wind velocity impact on thermal bridging is quantified.•Adjusting procedure for the Ψ-value measured at different wind velocities is developed.•This procedure allows measured and standard Ψ-value comparison. Improving the thermal performance of the existing building stock is essential to significantly reduce the overall energy consumption in the building sector. A key objective is the retrofitting of the existing building envelope. A necessary first step in the building envelope optimization process is the assessment of its actual thermal performance. This assessment should be repeated after retrofitting to clearly define the improvements that were made and the heat loss reduction that was achieved. In this study, an efficient, non-destructive, in-situ measurement method, based on an outdoor infrared thermographic survey, is developed to determine the thermal bridging performance. As wind velocity significantly influences the heat losses through the building envelope, this study includes quantification of the wind velocity impact on the Ψ-value. This was assessed by undertaking ITT of the same thermal bridge at various wind velocities, in a controlled environment, in a hot box device. The results showed that the Ψ-value is highly dependent on wind velocity so that measurement of the Ψ-value taken at different wind conditions cannot be directly compared. An adjustment procedure is proposed that can be used to convert the Ψ-value measured at any wind velocity to a standard value corresponding to a velocity of 4m/s. From a practical point of view, this adjustment procedure makes the methodology widely applicable.
ISSN:0306-2619
1872-9118
DOI:10.1016/j.apenergy.2017.09.047