Thermal characteristics and comfort assessment of enclosed large-span membrane stadiums

•Winter and summer experiments were done to measure temperature distribution.•Temperature stratification, orientation and location effects are quantified.•Inside and outside air ΔTs: 6.2 °C and 3.1 °C for summer and winter experiments.•Winter: −1.2 

Saved in:
Bibliographic Details
Published in:Applied energy 2018-11, Vol.229, p.728-735
Main Authors: Hu, Jianhui, Chen, Wujun, Zhang, Sihao, Yin, Yue, Li, Yipo, Yang, Deqing
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Winter and summer experiments were done to measure temperature distribution.•Temperature stratification, orientation and location effects are quantified.•Inside and outside air ΔTs: 6.2 °C and 3.1 °C for summer and winter experiments.•Winter: −1.2 