Loading…

Compatibility investigation and techno-economic performance optimization of whole geothermal power generation system

•Compatibility between geothermal exploitation and utilization system is investigated.•Thermodynamic analysis is performed based on dynamic process.•Multi-objective optimization and technoeconomic evaluation are conducted.•Single-flash with organic Rankine cycle system is more suitable for proposed...

Full description

Saved in:
Bibliographic Details
Published in:Applied energy 2022-12, Vol.328, p.120165, Article 120165
Main Authors: Xie, Jingxuan, Wang, Jiansheng
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Compatibility between geothermal exploitation and utilization system is investigated.•Thermodynamic analysis is performed based on dynamic process.•Multi-objective optimization and technoeconomic evaluation are conducted.•Single-flash with organic Rankine cycle system is more suitable for proposed EGS. Appropriate compatibility between exploitation and utilization systems is of critical importance to geothermal electricity. However, few research works focused on the optimal dynamic matching between subsurface heat extraction system and surface power generation system according to the dynamic process of enhanced geothermal system (EGS). In present work, a potential EGS with pinnate horizontal well is proposed to generate electricity by incorporating three typical power generation systems, namely single-flash (SF) system, double-flash (DF) system and single-flash with organic Rankine cycle (SFORC) system. System coupling is achieved to explore the optimum operation strategy of surface power generation system by considering the dynamic characteristics of geothermal fluid temperature and flow rate. The reliability of numerical method and thermodynamic model used in present work are validated by the theoretical model. Furthermore, the response surface methodology is employed to optimize the operation strategy of proposed EGS. Based on the maximization of exergy efficiency and minimization of total cost, the optimum running strategies and techno-economic performance of proposed power generation systems are obtained, respectively. The results indicate that temperature drop of thermal reservoir is significantly affected by the combined effect of injection flow rate and reservoir permeability. The net output exergy is proportional to branch well length and reservoir permeability, and inversely proportional to the injection temperature and injection flow rate. Compared with the SF and DF systems, SFORC system is more compatible and economical to be applied in the proposed EGS. After 30 years of operating, the net revenue of SFORC system can reach to 2.66 × 108 USD, which are 2.30 and 1.02 times more than those of SF and DF systems, respectively. The corresponding flash temperature of SFORC is the same as production temperature of the EGS. Meanwhile, the evaporation temperature of n-pentane will drop in four steps from 405.15 K to 399.15 K.
ISSN:0306-2619
1872-9118
DOI:10.1016/j.apenergy.2022.120165