Performance comparison and characterization of multi-pressure vapor compression systems at optimized conditions for simultaneous cooling and heating application

•Multi-pressure systems can improve the performance by greater than 30 % at high temperature lifts.•Multi-pressure systems with R245fa are good for combined cooling-heating applications.•Ammonia systems are prone to lubrication breakdown.•Performance of flash tank system and ejector systems are bett...

Full description

Saved in:
Bibliographic Details
Published in:Applied thermal engineering 2023-05, Vol.225, p.120196, Article 120196
Main Authors: Fernandez, Ken Bryan, Abuan, Binoe, Berana, Menandro
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:•Multi-pressure systems can improve the performance by greater than 30 % at high temperature lifts.•Multi-pressure systems with R245fa are good for combined cooling-heating applications.•Ammonia systems are prone to lubrication breakdown.•Performance of flash tank system and ejector systems are better than cascade systems.•Vapor compression with flash tank system is good to prevent lubrication breakdown. We performed numerical thermodynamic analyses of 3 multi-pressure vapor compression system configurations (cascaded, with flash tank, and with ejector) to evaluate their coefficient of performance improvements in combined cooling and heating applications. Six refrigerants were evaluated, and 25 temperature pairs of −15 °C to 25 °C cooling and 45 °C to 85 °C heating were specified. Critical parameters of the 3 configurations were varied for performance optimization. The compressor outlet temperature was constrained to prevent lubricant breakdown in actual implementation. Maximum performance improvements of 34.41 %, 39.20 %, and 46.34 % for the cascade, with flash tank, and with ejector systems, respectively, were attained. Moreover, the total number of temperature pairs exceeding the temperature limit was reduced from 19/25 to 17/25, 1/25, and 9/25 for the cascade, with flash tank, and with ejector systems, respectively. The best refrigerants to use were found to be Ammonia or R245fa as the low-pressure loop refrigerant with R245fa as the high-pressure loop refrigerant for cascade systems, Ammonia or R245fa for systems with flash tank, and R245fa for systems with ejector. This work demonstrated and quantified the ability of multi pressure configurations to increase the performance of vapor compression systems in simultaneous cooling and heating applications.
ISSN:1359-4311
DOI:10.1016/j.applthermaleng.2023.120196