Evaluation of predictive performance of PLS regression models after being transferred from benchtop to handheld NIR spectrometers

With increasing availability of handheld near infrared (NIR) spectrometers, it would be beneficial to transfer an existing calibration model for a benchtop NIR to another spectrometer with minimal loss in prediction performance. In this study, a benchtop FOSS XDS Rapid Content Analyzer (B1) was cali...

Full description

Saved in:
Bibliographic Details
Published in:Biosystems engineering 2022-06, Vol.218, p.245-255
Main Authors: Rukundo, Isaac R., Danao, Mary-Grace C., Mitchell, Robert B., Weller, Curtis L.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:With increasing availability of handheld near infrared (NIR) spectrometers, it would be beneficial to transfer an existing calibration model for a benchtop NIR to another spectrometer with minimal loss in prediction performance. In this study, a benchtop FOSS XDS Rapid Content Analyzer (B1) was calibrated to estimate nitrogen content (N) of warm-season grasses using partial least squares (PLS) regression. This model had a coefficient of determination of validation (r2) of 0.928 and ratio of standard deviation to standard error of prediction (RPD) of 3.78. The calibration model was transferred to another benchtop, FOSS 6500 (B2) and two handheld spectrometers, ASD QualitySpec® Trek and Tellspec Enterprise (H1 and H2, respectively). B1, B2, and H1 had similar specifications, while H2 had a shorter spectral range with a wider spectral interval. When the calibration model for B1 was transferred to B2 and H1, both r2 and RPD decreased slightly. However, transferring the model to H2 required truncating and standardizing the B1 spectra using piecewise reverse standardization and more preprocessing than was done for B2 and H1. The calibration model developed for the standardised B1 spectra had an r2 = 0.889 and RPD = 1.79, which were lower than those for the original calibration model developed for B1. When this new model was transferred and applied to H2, r2 decreased further to 0.726 while RPD remained 1.79. Based on these values, the model to H2 spectrometer can be used for rough screening purposes. [Display omitted] •Forage nitrogen concentration was predicted using benchtop and handheld NIR spectrometers.•A calibration model was transferred from a benchtop NIR to other spectrometers.•Transfer to a similar benchtop spectrometer required no standardization of spectra.•Transfer to a handheld spectrometer required truncating and additional preprocessing of spectra.•Transfer to a handheld spectrometer required applying fewer latent variables of the original model.
ISSN:1537-5110
1537-5129
DOI:10.1016/j.biosystemseng.2022.04.014