Loading…

Chloramphenicol removal by zero valent iron activated peroxymonosulfate system: Kinetics and mechanism of radical generation

[Display omitted] •PMS activation with Fe0 was efficient for removal of chloramphenicol.•Both HO and SO4− was identified in Fe0/PMS system by in-situ EPR tests.•Cycle of Fe2+-Fe3+ on the Fe0 was answerable for radical generation.•FeSO4 layer was assembled on the FeOOH layer after Fe0 exposure to PMS...

Full description

Saved in:
Bibliographic Details
Published in:Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2018-02, Vol.334, p.1006-1015
Main Authors: Tan, Chaoqun, Dong, Yujie, Fu, Dafang, Gao, Naiyun, Ma, Jinxia, Liu, Xiaoyu
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:[Display omitted] •PMS activation with Fe0 was efficient for removal of chloramphenicol.•Both HO and SO4− was identified in Fe0/PMS system by in-situ EPR tests.•Cycle of Fe2+-Fe3+ on the Fe0 was answerable for radical generation.•FeSO4 layer was assembled on the FeOOH layer after Fe0 exposure to PMS. Zero valent iron (Fe0) was used as a catalyst to activate peroxymonosulfate (PMS) for removal of chloramphenicol (CAP). About 95.2% of 10 mg/L CAP was removed by 0.2 mM peroxymonosulfate and 0.5 g/L Fe0 at neutral pH, with little Fe3+ leaching. The degradation reactions well followed a pseudo-first-order kinetics pattern (R2 > 0.95). The production of hydroxyl radicals (OH) and sulfate radicals (SO4−) was directly identified in in-situ Electron paramagnetic resonance (EPR) tests with 0.1 M 5,5-dimethyl-1-pyrrolidine N-oxide (DMPO) and indirectly identified through quenching tests. The second order rate constant between CAP and SO4− was ascertained to be 6.18 × 1010 M−1 s−1 in competition reaction. According to SEM and XRD analysis, the average diameter of catalyst was elevated to be about 88 nm after use. Possible mechanisms on the radical generation were proposed based on the results of EPR and XPS analyses. It emerged that the cycle of Fe2+-Fe3+ on the Fe0 was answerable for the OH and SO4− generation, and iron sulfate layer was assembled on the Fe0 following exposure to peroxymonosulfate compared to the FeOOH layer present on the fresh Fe0. While the presence of common anions including Cl−, CO32−, Fe2+, Cu2+ and Mn2+ will inhibit the degradation of CAP in Fe0/PMS system. Besides, Fe0/PMS pre-oxidation before chlorine or chloramine engendered in a sharp increment in the concentration of disinfection by-products (DBPs) precursors. The results manifested that Fe0/PMS was effective in CAP removal at neutral pH, whereas it should be more cautiously investigated when combined with chlorine disinfection.
ISSN:1385-8947
1873-3212
DOI:10.1016/j.cej.2017.10.020