Loading…
Spatially resolved direct gas-phase thermometry in chemical reactors using NMR
[Display omitted] •Direct measurement of gas-phase temperature using NMR with spatial resolution.•In-situ NMR measurements of gas phase temperature exceeding 350 °C.•Comparison with NMR thermometer measurements based on diffusion coefficient.•Simultaneous measurement of temperature and density.•Poss...
Saved in:
Published in: | Chemical engineering journal (Lausanne, Switzerland : 1996) Switzerland : 1996), 2022-04, Vol.433, p.133583, Article 133583 |
---|---|
Main Authors: | , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | [Display omitted]
•Direct measurement of gas-phase temperature using NMR with spatial resolution.•In-situ NMR measurements of gas phase temperature exceeding 350 °C.•Comparison with NMR thermometer measurements based on diffusion coefficient.•Simultaneous measurement of temperature and density.•Possibility for direct application in (heterogenous) gas-phase reactions.
In the last decade, in-situ studies using nuclear magnetic resonance (NMR) showed the possibility to monitor local transport phenomena of gas-phase reactions inside opaque structures. While spatial species concentration is known to be accessible operando during heterogeneously catalyzed gas-phase reactions, the spatial acquisition of gas temperatures has proven to be challenging. So far, temperature information is gathered by auxiliary liquid-filled capillaries with temperature-dependent NMR-properties. Here, we present a method for spatially resolved temperature and density measurements of gases using the temperature dependence of the signal amplitude and the longitudinal relaxation time (T1). In order to support the proposed method, temperature measurements of methane-filled tubes are carried out and compared to state-of-the-art temperature measurements using glycerol-filled capillaries. To demonstrate the applicability of the method during heterogeneously catalyzed gas-phase reactions, we measured the temperature operando inside a catalytically active honeycomb structure at standard pressure. The results show that direct temperature measurements of gases are possible, even though the low pressure inside the methane-filled tubes led to a low signal-to-noise ratio which compromised the accuracy of the data yielding relative errors of up to 7 %. This study focusses on temperature measurements of pure methane only. When applied to mixtures of gases, however, the proposed method has the potential to measure gas temperature and concentration at the same time. |
---|---|
ISSN: | 1385-8947 1873-3212 |
DOI: | 10.1016/j.cej.2021.133583 |