Loading…
Efficient analysis of selected estrogens using fabric phase sorptive extraction and high performance liquid chromatography-fluorescence detection
•A new sample preparation approach “Fabric Phase Sorptive Extraction” is proposed.•Selectivity of sol–gel precursor, organic polymer, and substrate are combined.•FPSE medium can be inserted directly into the unmodified aqueous/biological sample.•Strong chemical bonding between substrate and sorbent...
Saved in:
Published in: | Journal of Chromatography A 2014-09, Vol.1359, p.16-25 |
---|---|
Main Authors: | , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •A new sample preparation approach “Fabric Phase Sorptive Extraction” is proposed.•Selectivity of sol–gel precursor, organic polymer, and substrate are combined.•FPSE medium can be inserted directly into the unmodified aqueous/biological sample.•Strong chemical bonding between substrate and sorbent offers unique robustness.•Parameters impacting fabric phase sorptive extraction performance were optimized.
A simple, fast and sensitive analytical method using fabric phase sorptive extraction (FPSE) followed by high performance liquid chromatography with fluorescence detection (HPLC-FLD) has been developed for efficient quantification of biologically important molecules e.g., 17α-ethynylestradiol (EE2), β-estradiol (E2) and bisphenol A (BPA). FPSE is a new sorptive extraction technique that integrates the advantages of permeable sol–gel derived hybrid organic–inorganic sorbents with flexible and permeable fabric substrates, resulting in a highly efficient and sensitive extraction media that can be introduced directly into any kind of fluidic matrix. Various factors affecting the performance of FPSE technique were optimized. The chromatographic separation was carried using mobile phase acetonitrile/methanol/water (30:15:55; v/v) at a flow rate 1.0mL/min on C18 column with fluorescence detection (λex=280nm and λem=310nm). The calibration curves of the target analytes were prepared with good correlation coefficient values (R2>0.992). Limit of detection (LOD) values range from 20 to 42pg/mL. The developed method was applied successfully for the analysis of estrogen molecules in urine and various kinds of aqueous samples. |
---|---|
ISSN: | 0021-9673 |
DOI: | 10.1016/j.chroma.2014.07.013 |