Loading…

Semi-permanent cationic coating for protein separations

•A phospholipid-CTAB coating is developed for anionic and cationic protein separations.•The importance of the hydrophobic tail of CTAB to coating formation is established.•The electroosmotic flow is similar for separations at pH ranging from 4 to 8.•The coating is stable when subjected to extensive...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 2019-12, Vol.1607, p.460397, Article 460397
Main Authors: Crihfield, C.L., Kristoff, C.J., Veltri, L.M., Penny, W.M., Holland, L.A.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13
cites cdi_FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13
container_end_page
container_issue
container_start_page 460397
container_title Journal of Chromatography A
container_volume 1607
creator Crihfield, C.L.
Kristoff, C.J.
Veltri, L.M.
Penny, W.M.
Holland, L.A.
description •A phospholipid-CTAB coating is developed for anionic and cationic protein separations.•The importance of the hydrophobic tail of CTAB to coating formation is established.•The electroosmotic flow is similar for separations at pH ranging from 4 to 8.•The coating is stable when subjected to extensive flushing and repeated protein injections.•Separations are tuned using pH to distinguish isoforms with slight mobility differences. Capillary electrophoresis has been used extensively for protein separations, but interactions of proteins with the negative charge on the surface of fused silica capillary create band broadening and diminish the separation efficiency. Coatings developed to mask the negative charge of the capillary affect the electroosmotic flow. The method presented in this work addresses these concerns through the use of a two-layer coating of a semi-permanent phospholipid substrate and cetyltrimethylammonium bromide (CTAB). When used alone, phospholipid coating suppresses the electroosmotic flow but cannot be used to simultaneously separate anionic and cationic proteins. When used alone, CTAB creates a dynamic coating that facilitates the separation of cationic proteins with good efficiency, but reduces the separation efficiency of anionic proteins. The use of a hybrid phospholipid-CTAB surface coating alleviates protein adsorption, as demonstrated through a comparison of protein separations obtained with a bare fused silica capillary. The hybrid phospholipid-CTAB surface enables high efficiency separations of cationic and anionic proteins simultaneously. This work verifies the role of the hydrophobic tail of CTAB in developing a stable coating with an electroosmotic flow of 3.14 × 10−4 cm2V-1s-1 (n = 10) from the cathode to the anode at a pH of 7. The coating yields a stable electroosmotic flow even after 2 h of flushing with background electrolyte devoid of CTAB (n = 3) and six consecutive protein injections with no flush sequence between runs. The coating can be used with background electrolytes with pH values ranging from 4 to 8 while maintaining 1% RSD (n = 10) in the electroosmotic flow for each background electrolyte. Six model proteins, lysozyme, ribonuclease A, α-chymotrypsinogen A, enolase, transferrin, and α-1-antitrypsin, with pI values ranging from 4.4 to 11 were used to demonstrate the stability of the phospholipid-CTAB coating, the lack of protein interaction with the wall, and the utility of the coating for the separation of protein
doi_str_mv 10.1016/j.chroma.2019.460397
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_chroma_2019_460397</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967319307812</els_id><sourcerecordid>S0021967319307812</sourcerecordid><originalsourceid>FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13</originalsourceid><addsrcrecordid>eNp9j71OxDAQhF2AxHHwBhR5gYTdXBLHDRI68SedRAHUlr1eg08kjuwIibfnjlBTzRQzo_mEuEKoELC73lf0keJgqhpQVU0HGyVPxAqgxlJ1cnMmznPeA6AEWa-EfOEhlBOnwYw8zgWZOcQxUEHx4Mb3wsdUTCnOHMYi82TSbyBfiFNvPjNf_ulavN3fvW4fy93zw9P2dldSA_1ccm865Z2UvkdHNWJn0UoF1Hh2XINU1FtZt2DBEvuukbZ32DaubVlZh5u1aJZdSjHnxF5PKQwmfWsEfQTWe70A6yOwXoAPtZulxodvX4GTzhR4JHYhMc3axfD_wA9hF2O3</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Semi-permanent cationic coating for protein separations</title><source>Elsevier</source><creator>Crihfield, C.L. ; Kristoff, C.J. ; Veltri, L.M. ; Penny, W.M. ; Holland, L.A.</creator><creatorcontrib>Crihfield, C.L. ; Kristoff, C.J. ; Veltri, L.M. ; Penny, W.M. ; Holland, L.A.</creatorcontrib><description>•A phospholipid-CTAB coating is developed for anionic and cationic protein separations.•The importance of the hydrophobic tail of CTAB to coating formation is established.•The electroosmotic flow is similar for separations at pH ranging from 4 to 8.•The coating is stable when subjected to extensive flushing and repeated protein injections.•Separations are tuned using pH to distinguish isoforms with slight mobility differences. Capillary electrophoresis has been used extensively for protein separations, but interactions of proteins with the negative charge on the surface of fused silica capillary create band broadening and diminish the separation efficiency. Coatings developed to mask the negative charge of the capillary affect the electroosmotic flow. The method presented in this work addresses these concerns through the use of a two-layer coating of a semi-permanent phospholipid substrate and cetyltrimethylammonium bromide (CTAB). When used alone, phospholipid coating suppresses the electroosmotic flow but cannot be used to simultaneously separate anionic and cationic proteins. When used alone, CTAB creates a dynamic coating that facilitates the separation of cationic proteins with good efficiency, but reduces the separation efficiency of anionic proteins. The use of a hybrid phospholipid-CTAB surface coating alleviates protein adsorption, as demonstrated through a comparison of protein separations obtained with a bare fused silica capillary. The hybrid phospholipid-CTAB surface enables high efficiency separations of cationic and anionic proteins simultaneously. This work verifies the role of the hydrophobic tail of CTAB in developing a stable coating with an electroosmotic flow of 3.14 × 10−4 cm2V-1s-1 (n = 10) from the cathode to the anode at a pH of 7. The coating yields a stable electroosmotic flow even after 2 h of flushing with background electrolyte devoid of CTAB (n = 3) and six consecutive protein injections with no flush sequence between runs. The coating can be used with background electrolytes with pH values ranging from 4 to 8 while maintaining 1% RSD (n = 10) in the electroosmotic flow for each background electrolyte. Six model proteins, lysozyme, ribonuclease A, α-chymotrypsinogen A, enolase, transferrin, and α-1-antitrypsin, with pI values ranging from 4.4 to 11 were used to demonstrate the stability of the phospholipid-CTAB coating, the lack of protein interaction with the wall, and the utility of the coating for the separation of proteins of similar isoelectric points and of protein isoforms.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2019.460397</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Capillary electrophoresis ; Electroomostic flow ; pH-stability ; Protein adsorption ; Semi-permanent coating ; Surface modification</subject><ispartof>Journal of Chromatography A, 2019-12, Vol.1607, p.460397, Article 460397</ispartof><rights>2019 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><oa>free_for_read</oa><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13</citedby><cites>FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13</cites><orcidid>0000-0002-7534-6810</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Crihfield, C.L.</creatorcontrib><creatorcontrib>Kristoff, C.J.</creatorcontrib><creatorcontrib>Veltri, L.M.</creatorcontrib><creatorcontrib>Penny, W.M.</creatorcontrib><creatorcontrib>Holland, L.A.</creatorcontrib><title>Semi-permanent cationic coating for protein separations</title><title>Journal of Chromatography A</title><description>•A phospholipid-CTAB coating is developed for anionic and cationic protein separations.•The importance of the hydrophobic tail of CTAB to coating formation is established.•The electroosmotic flow is similar for separations at pH ranging from 4 to 8.•The coating is stable when subjected to extensive flushing and repeated protein injections.•Separations are tuned using pH to distinguish isoforms with slight mobility differences. Capillary electrophoresis has been used extensively for protein separations, but interactions of proteins with the negative charge on the surface of fused silica capillary create band broadening and diminish the separation efficiency. Coatings developed to mask the negative charge of the capillary affect the electroosmotic flow. The method presented in this work addresses these concerns through the use of a two-layer coating of a semi-permanent phospholipid substrate and cetyltrimethylammonium bromide (CTAB). When used alone, phospholipid coating suppresses the electroosmotic flow but cannot be used to simultaneously separate anionic and cationic proteins. When used alone, CTAB creates a dynamic coating that facilitates the separation of cationic proteins with good efficiency, but reduces the separation efficiency of anionic proteins. The use of a hybrid phospholipid-CTAB surface coating alleviates protein adsorption, as demonstrated through a comparison of protein separations obtained with a bare fused silica capillary. The hybrid phospholipid-CTAB surface enables high efficiency separations of cationic and anionic proteins simultaneously. This work verifies the role of the hydrophobic tail of CTAB in developing a stable coating with an electroosmotic flow of 3.14 × 10−4 cm2V-1s-1 (n = 10) from the cathode to the anode at a pH of 7. The coating yields a stable electroosmotic flow even after 2 h of flushing with background electrolyte devoid of CTAB (n = 3) and six consecutive protein injections with no flush sequence between runs. The coating can be used with background electrolytes with pH values ranging from 4 to 8 while maintaining 1% RSD (n = 10) in the electroosmotic flow for each background electrolyte. Six model proteins, lysozyme, ribonuclease A, α-chymotrypsinogen A, enolase, transferrin, and α-1-antitrypsin, with pI values ranging from 4.4 to 11 were used to demonstrate the stability of the phospholipid-CTAB coating, the lack of protein interaction with the wall, and the utility of the coating for the separation of proteins of similar isoelectric points and of protein isoforms.</description><subject>Capillary electrophoresis</subject><subject>Electroomostic flow</subject><subject>pH-stability</subject><subject>Protein adsorption</subject><subject>Semi-permanent coating</subject><subject>Surface modification</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2019</creationdate><recordtype>article</recordtype><recordid>eNp9j71OxDAQhF2AxHHwBhR5gYTdXBLHDRI68SedRAHUlr1eg08kjuwIibfnjlBTzRQzo_mEuEKoELC73lf0keJgqhpQVU0HGyVPxAqgxlJ1cnMmznPeA6AEWa-EfOEhlBOnwYw8zgWZOcQxUEHx4Mb3wsdUTCnOHMYi82TSbyBfiFNvPjNf_ulavN3fvW4fy93zw9P2dldSA_1ccm865Z2UvkdHNWJn0UoF1Hh2XINU1FtZt2DBEvuukbZ32DaubVlZh5u1aJZdSjHnxF5PKQwmfWsEfQTWe70A6yOwXoAPtZulxodvX4GTzhR4JHYhMc3axfD_wA9hF2O3</recordid><startdate>20191206</startdate><enddate>20191206</enddate><creator>Crihfield, C.L.</creator><creator>Kristoff, C.J.</creator><creator>Veltri, L.M.</creator><creator>Penny, W.M.</creator><creator>Holland, L.A.</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0002-7534-6810</orcidid></search><sort><creationdate>20191206</creationdate><title>Semi-permanent cationic coating for protein separations</title><author>Crihfield, C.L. ; Kristoff, C.J. ; Veltri, L.M. ; Penny, W.M. ; Holland, L.A.</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2019</creationdate><topic>Capillary electrophoresis</topic><topic>Electroomostic flow</topic><topic>pH-stability</topic><topic>Protein adsorption</topic><topic>Semi-permanent coating</topic><topic>Surface modification</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Crihfield, C.L.</creatorcontrib><creatorcontrib>Kristoff, C.J.</creatorcontrib><creatorcontrib>Veltri, L.M.</creatorcontrib><creatorcontrib>Penny, W.M.</creatorcontrib><creatorcontrib>Holland, L.A.</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Crihfield, C.L.</au><au>Kristoff, C.J.</au><au>Veltri, L.M.</au><au>Penny, W.M.</au><au>Holland, L.A.</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Semi-permanent cationic coating for protein separations</atitle><jtitle>Journal of Chromatography A</jtitle><date>2019-12-06</date><risdate>2019</risdate><volume>1607</volume><spage>460397</spage><pages>460397-</pages><artnum>460397</artnum><issn>0021-9673</issn><abstract>•A phospholipid-CTAB coating is developed for anionic and cationic protein separations.•The importance of the hydrophobic tail of CTAB to coating formation is established.•The electroosmotic flow is similar for separations at pH ranging from 4 to 8.•The coating is stable when subjected to extensive flushing and repeated protein injections.•Separations are tuned using pH to distinguish isoforms with slight mobility differences. Capillary electrophoresis has been used extensively for protein separations, but interactions of proteins with the negative charge on the surface of fused silica capillary create band broadening and diminish the separation efficiency. Coatings developed to mask the negative charge of the capillary affect the electroosmotic flow. The method presented in this work addresses these concerns through the use of a two-layer coating of a semi-permanent phospholipid substrate and cetyltrimethylammonium bromide (CTAB). When used alone, phospholipid coating suppresses the electroosmotic flow but cannot be used to simultaneously separate anionic and cationic proteins. When used alone, CTAB creates a dynamic coating that facilitates the separation of cationic proteins with good efficiency, but reduces the separation efficiency of anionic proteins. The use of a hybrid phospholipid-CTAB surface coating alleviates protein adsorption, as demonstrated through a comparison of protein separations obtained with a bare fused silica capillary. The hybrid phospholipid-CTAB surface enables high efficiency separations of cationic and anionic proteins simultaneously. This work verifies the role of the hydrophobic tail of CTAB in developing a stable coating with an electroosmotic flow of 3.14 × 10−4 cm2V-1s-1 (n = 10) from the cathode to the anode at a pH of 7. The coating yields a stable electroosmotic flow even after 2 h of flushing with background electrolyte devoid of CTAB (n = 3) and six consecutive protein injections with no flush sequence between runs. The coating can be used with background electrolytes with pH values ranging from 4 to 8 while maintaining 1% RSD (n = 10) in the electroosmotic flow for each background electrolyte. Six model proteins, lysozyme, ribonuclease A, α-chymotrypsinogen A, enolase, transferrin, and α-1-antitrypsin, with pI values ranging from 4.4 to 11 were used to demonstrate the stability of the phospholipid-CTAB coating, the lack of protein interaction with the wall, and the utility of the coating for the separation of proteins of similar isoelectric points and of protein isoforms.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.chroma.2019.460397</doi><orcidid>https://orcid.org/0000-0002-7534-6810</orcidid><oa>free_for_read</oa></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2019-12, Vol.1607, p.460397, Article 460397
issn 0021-9673
language eng
recordid cdi_crossref_primary_10_1016_j_chroma_2019_460397
source Elsevier
subjects Capillary electrophoresis
Electroomostic flow
pH-stability
Protein adsorption
Semi-permanent coating
Surface modification
title Semi-permanent cationic coating for protein separations
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2024-12-29T04%3A45%3A27IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Semi-permanent%20cationic%20coating%20for%20protein%20separations&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Crihfield,%20C.L.&rft.date=2019-12-06&rft.volume=1607&rft.spage=460397&rft.pages=460397-&rft.artnum=460397&rft.issn=0021-9673&rft_id=info:doi/10.1016/j.chroma.2019.460397&rft_dat=%3Celsevier_cross%3ES0021967319307812%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c408t-e8a69fd77f81dc2116b1b790c4fede2079c8b7250b0bcef647b8d154d55e9bd13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true