Loading…

Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength

•Retention correlation between reverse-phase CCC and HPLC was studied.•Two typical biphasic solvent systems were investigated for retention correlation.•Big difference in elution sequence was found for CCC using specific volume ratio.•High orthogonality could be obtained for the two chromatographic...

Full description

Saved in:
Bibliographic Details
Published in:Journal of Chromatography A 2023-09, Vol.1707, p.464322, Article 464322
Main Authors: Lin, Tingting, Zhu, Beibei, Wen, Mengyi, Ma, Chenlei, Tong, Shengqiang
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by
cites cdi_FETCH-LOGICAL-c288t-e3834ecf5b4fac047a5393fb9e46510755964084d0dbcb9f2afa458651381fc63
container_end_page
container_issue
container_start_page 464322
container_title Journal of Chromatography A
container_volume 1707
creator Lin, Tingting
Zhu, Beibei
Wen, Mengyi
Ma, Chenlei
Tong, Shengqiang
description •Retention correlation between reverse-phase CCC and HPLC was studied.•Two typical biphasic solvent systems were investigated for retention correlation.•Big difference in elution sequence was found for CCC using specific volume ratio.•High orthogonality could be obtained for the two chromatographic methods. Correlation of elution performance between reversed phase countercurrent chromatography and liquid chromatography was investigated using five selected natural components. Theoretical guidance for orthogonality of two-dimensional countercurrent chromatography and liquid chromatography was proposed. The difference in retention behavior between countercurrent chromatography and liquid chromatography was studied when the mobile phase was composed of methanol and water by measuring the partition behavior of five selected compounds in two typical biphasic solvent systems composed of n-hexane-ethyl acetate-methanol-water and chloroform-methanol-water. An orthogonal diagram between countercurrent chromatography and liquid chromatography was obtained by normalized treatment of the measured partition coefficients and capacity factors. The experimental results showed that each biphasic solvent system used for countercurrent chromatography had a high orthogonality with liquid chromatography when a specific volume ratio was used.
doi_str_mv 10.1016/j.chroma.2023.464322
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_chroma_2023_464322</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0021967323005472</els_id><sourcerecordid>S0021967323005472</sourcerecordid><originalsourceid>FETCH-LOGICAL-c288t-e3834ecf5b4fac047a5393fb9e46510755964084d0dbcb9f2afa458651381fc63</originalsourceid><addsrcrecordid>eNp9kMtOwzAQRb0AiVL4Axb5gQS_8togoYqXVAkJwdpynHHjKrWL7Qb1L_hkkoYVC1Yz0uicO7oI3RCcEUyK222mOu92MqOYsowXnFF6hhYYU5LWRcku0GUIW4xJiUu6QN9vEMFG42yinPfQy9MubZs4Hzu3cVb2Jh6TBuIXgE08DOADtMm-kwFG6GAjeHUYWRuTOTu6jZf77njS9ObzYNq_l0ZOjjEpuH6YyBBHwSZ2V-hcyz7A9e9coo_Hh_fVc7p-fXpZ3a9TRasqpsAqxkHpvOFaKsxLmbOa6aYGXuQEl3leFxxXvMVto5paU6klz6vxxiqiVcGWiM9e5V0IHrTYe7OT_igIFlOTYivmn8XUpJibHLG7GYPxt8GAF0EZsApa40FF0Trzv-AHzhyGKQ</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength</title><source>ScienceDirect Freedom Collection</source><creator>Lin, Tingting ; Zhu, Beibei ; Wen, Mengyi ; Ma, Chenlei ; Tong, Shengqiang</creator><creatorcontrib>Lin, Tingting ; Zhu, Beibei ; Wen, Mengyi ; Ma, Chenlei ; Tong, Shengqiang</creatorcontrib><description>•Retention correlation between reverse-phase CCC and HPLC was studied.•Two typical biphasic solvent systems were investigated for retention correlation.•Big difference in elution sequence was found for CCC using specific volume ratio.•High orthogonality could be obtained for the two chromatographic methods. Correlation of elution performance between reversed phase countercurrent chromatography and liquid chromatography was investigated using five selected natural components. Theoretical guidance for orthogonality of two-dimensional countercurrent chromatography and liquid chromatography was proposed. The difference in retention behavior between countercurrent chromatography and liquid chromatography was studied when the mobile phase was composed of methanol and water by measuring the partition behavior of five selected compounds in two typical biphasic solvent systems composed of n-hexane-ethyl acetate-methanol-water and chloroform-methanol-water. An orthogonal diagram between countercurrent chromatography and liquid chromatography was obtained by normalized treatment of the measured partition coefficients and capacity factors. The experimental results showed that each biphasic solvent system used for countercurrent chromatography had a high orthogonality with liquid chromatography when a specific volume ratio was used.</description><identifier>ISSN: 0021-9673</identifier><identifier>DOI: 10.1016/j.chroma.2023.464322</identifier><language>eng</language><publisher>Elsevier B.V</publisher><subject>Countercurrent chromatography ; Liquid chromatography ; Orthogonality ; Retention correlation</subject><ispartof>Journal of Chromatography A, 2023-09, Vol.1707, p.464322, Article 464322</ispartof><rights>2023 Elsevier B.V.</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><cites>FETCH-LOGICAL-c288t-e3834ecf5b4fac047a5393fb9e46510755964084d0dbcb9f2afa458651381fc63</cites><orcidid>0000-0001-5867-7354</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Lin, Tingting</creatorcontrib><creatorcontrib>Zhu, Beibei</creatorcontrib><creatorcontrib>Wen, Mengyi</creatorcontrib><creatorcontrib>Ma, Chenlei</creatorcontrib><creatorcontrib>Tong, Shengqiang</creatorcontrib><title>Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength</title><title>Journal of Chromatography A</title><description>•Retention correlation between reverse-phase CCC and HPLC was studied.•Two typical biphasic solvent systems were investigated for retention correlation.•Big difference in elution sequence was found for CCC using specific volume ratio.•High orthogonality could be obtained for the two chromatographic methods. Correlation of elution performance between reversed phase countercurrent chromatography and liquid chromatography was investigated using five selected natural components. Theoretical guidance for orthogonality of two-dimensional countercurrent chromatography and liquid chromatography was proposed. The difference in retention behavior between countercurrent chromatography and liquid chromatography was studied when the mobile phase was composed of methanol and water by measuring the partition behavior of five selected compounds in two typical biphasic solvent systems composed of n-hexane-ethyl acetate-methanol-water and chloroform-methanol-water. An orthogonal diagram between countercurrent chromatography and liquid chromatography was obtained by normalized treatment of the measured partition coefficients and capacity factors. The experimental results showed that each biphasic solvent system used for countercurrent chromatography had a high orthogonality with liquid chromatography when a specific volume ratio was used.</description><subject>Countercurrent chromatography</subject><subject>Liquid chromatography</subject><subject>Orthogonality</subject><subject>Retention correlation</subject><issn>0021-9673</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kMtOwzAQRb0AiVL4Axb5gQS_8togoYqXVAkJwdpynHHjKrWL7Qb1L_hkkoYVC1Yz0uicO7oI3RCcEUyK222mOu92MqOYsowXnFF6hhYYU5LWRcku0GUIW4xJiUu6QN9vEMFG42yinPfQy9MubZs4Hzu3cVb2Jh6TBuIXgE08DOADtMm-kwFG6GAjeHUYWRuTOTu6jZf77njS9ObzYNq_l0ZOjjEpuH6YyBBHwSZ2V-hcyz7A9e9coo_Hh_fVc7p-fXpZ3a9TRasqpsAqxkHpvOFaKsxLmbOa6aYGXuQEl3leFxxXvMVto5paU6klz6vxxiqiVcGWiM9e5V0IHrTYe7OT_igIFlOTYivmn8XUpJibHLG7GYPxt8GAF0EZsApa40FF0Trzv-AHzhyGKQ</recordid><startdate>20230927</startdate><enddate>20230927</enddate><creator>Lin, Tingting</creator><creator>Zhu, Beibei</creator><creator>Wen, Mengyi</creator><creator>Ma, Chenlei</creator><creator>Tong, Shengqiang</creator><general>Elsevier B.V</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-5867-7354</orcidid></search><sort><creationdate>20230927</creationdate><title>Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength</title><author>Lin, Tingting ; Zhu, Beibei ; Wen, Mengyi ; Ma, Chenlei ; Tong, Shengqiang</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c288t-e3834ecf5b4fac047a5393fb9e46510755964084d0dbcb9f2afa458651381fc63</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Countercurrent chromatography</topic><topic>Liquid chromatography</topic><topic>Orthogonality</topic><topic>Retention correlation</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Lin, Tingting</creatorcontrib><creatorcontrib>Zhu, Beibei</creatorcontrib><creatorcontrib>Wen, Mengyi</creatorcontrib><creatorcontrib>Ma, Chenlei</creatorcontrib><creatorcontrib>Tong, Shengqiang</creatorcontrib><collection>CrossRef</collection><jtitle>Journal of Chromatography A</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Lin, Tingting</au><au>Zhu, Beibei</au><au>Wen, Mengyi</au><au>Ma, Chenlei</au><au>Tong, Shengqiang</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength</atitle><jtitle>Journal of Chromatography A</jtitle><date>2023-09-27</date><risdate>2023</risdate><volume>1707</volume><spage>464322</spage><pages>464322-</pages><artnum>464322</artnum><issn>0021-9673</issn><abstract>•Retention correlation between reverse-phase CCC and HPLC was studied.•Two typical biphasic solvent systems were investigated for retention correlation.•Big difference in elution sequence was found for CCC using specific volume ratio.•High orthogonality could be obtained for the two chromatographic methods. Correlation of elution performance between reversed phase countercurrent chromatography and liquid chromatography was investigated using five selected natural components. Theoretical guidance for orthogonality of two-dimensional countercurrent chromatography and liquid chromatography was proposed. The difference in retention behavior between countercurrent chromatography and liquid chromatography was studied when the mobile phase was composed of methanol and water by measuring the partition behavior of five selected compounds in two typical biphasic solvent systems composed of n-hexane-ethyl acetate-methanol-water and chloroform-methanol-water. An orthogonal diagram between countercurrent chromatography and liquid chromatography was obtained by normalized treatment of the measured partition coefficients and capacity factors. The experimental results showed that each biphasic solvent system used for countercurrent chromatography had a high orthogonality with liquid chromatography when a specific volume ratio was used.</abstract><pub>Elsevier B.V</pub><doi>10.1016/j.chroma.2023.464322</doi><orcidid>https://orcid.org/0000-0001-5867-7354</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0021-9673
ispartof Journal of Chromatography A, 2023-09, Vol.1707, p.464322, Article 464322
issn 0021-9673
language eng
recordid cdi_crossref_primary_10_1016_j_chroma_2023_464322
source ScienceDirect Freedom Collection
subjects Countercurrent chromatography
Liquid chromatography
Orthogonality
Retention correlation
title Retention correlation and orthogonality between reversed phase countercurrent chromatography and liquid chromatography based on solvent strength
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-04T04%3A59%3A41IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Retention%20correlation%20and%20orthogonality%20between%20reversed%20phase%20countercurrent%20chromatography%20and%20liquid%20chromatography%20based%20on%20solvent%20strength&rft.jtitle=Journal%20of%20Chromatography%20A&rft.au=Lin,%20Tingting&rft.date=2023-09-27&rft.volume=1707&rft.spage=464322&rft.pages=464322-&rft.artnum=464322&rft.issn=0021-9673&rft_id=info:doi/10.1016/j.chroma.2023.464322&rft_dat=%3Celsevier_cross%3ES0021967323005472%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c288t-e3834ecf5b4fac047a5393fb9e46510755964084d0dbcb9f2afa458651381fc63%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true