Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics

Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatini...

Full description

Saved in:
Bibliographic Details
Published in:Composites communications 2023-10, Vol.42, p.101673, Article 101673
Main Authors: Saddique, Zohaib, Siddique, Tazeen, Shehzadi, Arooj, Ul-Ain, Qurat, Ali, Asghar, Iqbal, Naseer, Mujahid, Adnan, Afzal, Adeel
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13
cites cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13
container_end_page
container_issue
container_start_page 101673
container_title Composites communications
container_volume 42
creator Saddique, Zohaib
Siddique, Tazeen
Shehzadi, Arooj
Ul-Ain, Qurat
Ali, Asghar
Iqbal, Naseer
Mujahid, Adnan
Afzal, Adeel
description Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (
doi_str_mv 10.1016/j.coco.2023.101673
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_coco_2023_101673</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S245221392300181X</els_id><sourcerecordid>S245221392300181X</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</originalsourceid><addsrcrecordid>eNp9kEtOwzAQhiMEEhX0Aqx8gRQ_0jwkNqg8RSU2ZW0540nrKrEj222Ve3BgUgoSK1Yzml_faOZLkhtGZ4yy_HY7AwduxikX34NCnCUTns15ypmozv_0l8k0hC2llJUZzatqknyudtbYNQlog4lmb-JAXEPAo4pmTDA1Xe-NjahJ79qhQx_IwcQNsXggYdejT39ZJAE2La6xNRGJVdaBH0JUbSCN80Sb0Lug6hYJtgjRO9hgZ0C1ZPH2MMZqbV2IBsJ1ctGMFE5_6lXy8fS4Wryky_fn18X9MgVBaUznRd4wphVwxahqFDIGnPGyEIJiXddaMN7oDGktdJWpHOqyhqKEAjSvKTJxlfDTXvAuBI-NHF_tlB8ko_JoUm7lUa08qpUntSN0d4JwvGxv0MsABi2gNn78Smpn_sO_AO9xiCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><source>ScienceDirect Freedom Collection</source><creator>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</creator><creatorcontrib>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</creatorcontrib><description>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (&lt;1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function. [Display omitted] •Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</description><identifier>ISSN: 2452-2139</identifier><identifier>EISSN: 2452-2139</identifier><identifier>DOI: 10.1016/j.coco.2023.101673</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Creatinine ; Diagnostics ; Electrochemical sensors ; Nanocrystals ; Point-of-care</subject><ispartof>Composites communications, 2023-10, Vol.42, p.101673, Article 101673</ispartof><rights>2023 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</citedby><cites>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</cites><orcidid>0000-0001-8383-2627 ; 0000-0002-6528-7300 ; 0009-0008-7343-2193</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Saddique, Zohaib</creatorcontrib><creatorcontrib>Siddique, Tazeen</creatorcontrib><creatorcontrib>Shehzadi, Arooj</creatorcontrib><creatorcontrib>Ul-Ain, Qurat</creatorcontrib><creatorcontrib>Ali, Asghar</creatorcontrib><creatorcontrib>Iqbal, Naseer</creatorcontrib><creatorcontrib>Mujahid, Adnan</creatorcontrib><creatorcontrib>Afzal, Adeel</creatorcontrib><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><title>Composites communications</title><description>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (&lt;1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function. [Display omitted] •Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</description><subject>Creatinine</subject><subject>Diagnostics</subject><subject>Electrochemical sensors</subject><subject>Nanocrystals</subject><subject>Point-of-care</subject><issn>2452-2139</issn><issn>2452-2139</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kEtOwzAQhiMEEhX0Aqx8gRQ_0jwkNqg8RSU2ZW0540nrKrEj222Ve3BgUgoSK1Yzml_faOZLkhtGZ4yy_HY7AwduxikX34NCnCUTns15ypmozv_0l8k0hC2llJUZzatqknyudtbYNQlog4lmb-JAXEPAo4pmTDA1Xe-NjahJ79qhQx_IwcQNsXggYdejT39ZJAE2La6xNRGJVdaBH0JUbSCN80Sb0Lug6hYJtgjRO9hgZ0C1ZPH2MMZqbV2IBsJ1ctGMFE5_6lXy8fS4Wryky_fn18X9MgVBaUznRd4wphVwxahqFDIGnPGyEIJiXddaMN7oDGktdJWpHOqyhqKEAjSvKTJxlfDTXvAuBI-NHF_tlB8ko_JoUm7lUa08qpUntSN0d4JwvGxv0MsABi2gNn78Smpn_sO_AO9xiCg</recordid><startdate>202310</startdate><enddate>202310</enddate><creator>Saddique, Zohaib</creator><creator>Siddique, Tazeen</creator><creator>Shehzadi, Arooj</creator><creator>Ul-Ain, Qurat</creator><creator>Ali, Asghar</creator><creator>Iqbal, Naseer</creator><creator>Mujahid, Adnan</creator><creator>Afzal, Adeel</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8383-2627</orcidid><orcidid>https://orcid.org/0000-0002-6528-7300</orcidid><orcidid>https://orcid.org/0009-0008-7343-2193</orcidid></search><sort><creationdate>202310</creationdate><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><author>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Creatinine</topic><topic>Diagnostics</topic><topic>Electrochemical sensors</topic><topic>Nanocrystals</topic><topic>Point-of-care</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saddique, Zohaib</creatorcontrib><creatorcontrib>Siddique, Tazeen</creatorcontrib><creatorcontrib>Shehzadi, Arooj</creatorcontrib><creatorcontrib>Ul-Ain, Qurat</creatorcontrib><creatorcontrib>Ali, Asghar</creatorcontrib><creatorcontrib>Iqbal, Naseer</creatorcontrib><creatorcontrib>Mujahid, Adnan</creatorcontrib><creatorcontrib>Afzal, Adeel</creatorcontrib><collection>CrossRef</collection><jtitle>Composites communications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saddique, Zohaib</au><au>Siddique, Tazeen</au><au>Shehzadi, Arooj</au><au>Ul-Ain, Qurat</au><au>Ali, Asghar</au><au>Iqbal, Naseer</au><au>Mujahid, Adnan</au><au>Afzal, Adeel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</atitle><jtitle>Composites communications</jtitle><date>2023-10</date><risdate>2023</risdate><volume>42</volume><spage>101673</spage><pages>101673-</pages><artnum>101673</artnum><issn>2452-2139</issn><eissn>2452-2139</eissn><abstract>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (&lt;1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function. [Display omitted] •Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.coco.2023.101673</doi><orcidid>https://orcid.org/0000-0001-8383-2627</orcidid><orcidid>https://orcid.org/0000-0002-6528-7300</orcidid><orcidid>https://orcid.org/0009-0008-7343-2193</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 2452-2139
ispartof Composites communications, 2023-10, Vol.42, p.101673, Article 101673
issn 2452-2139
2452-2139
language eng
recordid cdi_crossref_primary_10_1016_j_coco_2023_101673
source ScienceDirect Freedom Collection
subjects Creatinine
Diagnostics
Electrochemical sensors
Nanocrystals
Point-of-care
title Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T01%3A18%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tuning%20sensitivity%20of%20creatinine-imprinted%20polymers%20with%20new%20super-sensitive%20schlegelite%20nanocrystals%20for%20disposable%20electrochemical%20CKD%20diagnostics&rft.jtitle=Composites%20communications&rft.au=Saddique,%20Zohaib&rft.date=2023-10&rft.volume=42&rft.spage=101673&rft.pages=101673-&rft.artnum=101673&rft.issn=2452-2139&rft.eissn=2452-2139&rft_id=info:doi/10.1016/j.coco.2023.101673&rft_dat=%3Celsevier_cross%3ES245221392300181X%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true