Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics
Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatini...
Saved in:
Published in: | Composites communications 2023-10, Vol.42, p.101673, Article 101673 |
---|---|
Main Authors: | , , , , , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
cited_by | cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13 |
---|---|
cites | cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13 |
container_end_page | |
container_issue | |
container_start_page | 101673 |
container_title | Composites communications |
container_volume | 42 |
creator | Saddique, Zohaib Siddique, Tazeen Shehzadi, Arooj Ul-Ain, Qurat Ali, Asghar Iqbal, Naseer Mujahid, Adnan Afzal, Adeel |
description | Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times ( |
doi_str_mv | 10.1016/j.coco.2023.101673 |
format | article |
fullrecord | <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_coco_2023_101673</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S245221392300181X</els_id><sourcerecordid>S245221392300181X</sourcerecordid><originalsourceid>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</originalsourceid><addsrcrecordid>eNp9kEtOwzAQhiMEEhX0Aqx8gRQ_0jwkNqg8RSU2ZW0540nrKrEj222Ve3BgUgoSK1Yzml_faOZLkhtGZ4yy_HY7AwduxikX34NCnCUTns15ypmozv_0l8k0hC2llJUZzatqknyudtbYNQlog4lmb-JAXEPAo4pmTDA1Xe-NjahJ79qhQx_IwcQNsXggYdejT39ZJAE2La6xNRGJVdaBH0JUbSCN80Sb0Lug6hYJtgjRO9hgZ0C1ZPH2MMZqbV2IBsJ1ctGMFE5_6lXy8fS4Wryky_fn18X9MgVBaUznRd4wphVwxahqFDIGnPGyEIJiXddaMN7oDGktdJWpHOqyhqKEAjSvKTJxlfDTXvAuBI-NHF_tlB8ko_JoUm7lUa08qpUntSN0d4JwvGxv0MsABi2gNn78Smpn_sO_AO9xiCg</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><source>ScienceDirect Freedom Collection</source><creator>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</creator><creatorcontrib>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</creatorcontrib><description>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (<1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function.
[Display omitted]
•Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</description><identifier>ISSN: 2452-2139</identifier><identifier>EISSN: 2452-2139</identifier><identifier>DOI: 10.1016/j.coco.2023.101673</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Creatinine ; Diagnostics ; Electrochemical sensors ; Nanocrystals ; Point-of-care</subject><ispartof>Composites communications, 2023-10, Vol.42, p.101673, Article 101673</ispartof><rights>2023 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</citedby><cites>FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</cites><orcidid>0000-0001-8383-2627 ; 0000-0002-6528-7300 ; 0009-0008-7343-2193</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,776,780,27901,27902</link.rule.ids></links><search><creatorcontrib>Saddique, Zohaib</creatorcontrib><creatorcontrib>Siddique, Tazeen</creatorcontrib><creatorcontrib>Shehzadi, Arooj</creatorcontrib><creatorcontrib>Ul-Ain, Qurat</creatorcontrib><creatorcontrib>Ali, Asghar</creatorcontrib><creatorcontrib>Iqbal, Naseer</creatorcontrib><creatorcontrib>Mujahid, Adnan</creatorcontrib><creatorcontrib>Afzal, Adeel</creatorcontrib><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><title>Composites communications</title><description>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (<1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function.
[Display omitted]
•Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</description><subject>Creatinine</subject><subject>Diagnostics</subject><subject>Electrochemical sensors</subject><subject>Nanocrystals</subject><subject>Point-of-care</subject><issn>2452-2139</issn><issn>2452-2139</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2023</creationdate><recordtype>article</recordtype><recordid>eNp9kEtOwzAQhiMEEhX0Aqx8gRQ_0jwkNqg8RSU2ZW0540nrKrEj222Ve3BgUgoSK1Yzml_faOZLkhtGZ4yy_HY7AwduxikX34NCnCUTns15ypmozv_0l8k0hC2llJUZzatqknyudtbYNQlog4lmb-JAXEPAo4pmTDA1Xe-NjahJ79qhQx_IwcQNsXggYdejT39ZJAE2La6xNRGJVdaBH0JUbSCN80Sb0Lug6hYJtgjRO9hgZ0C1ZPH2MMZqbV2IBsJ1ctGMFE5_6lXy8fS4Wryky_fn18X9MgVBaUznRd4wphVwxahqFDIGnPGyEIJiXddaMN7oDGktdJWpHOqyhqKEAjSvKTJxlfDTXvAuBI-NHF_tlB8ko_JoUm7lUa08qpUntSN0d4JwvGxv0MsABi2gNn78Smpn_sO_AO9xiCg</recordid><startdate>202310</startdate><enddate>202310</enddate><creator>Saddique, Zohaib</creator><creator>Siddique, Tazeen</creator><creator>Shehzadi, Arooj</creator><creator>Ul-Ain, Qurat</creator><creator>Ali, Asghar</creator><creator>Iqbal, Naseer</creator><creator>Mujahid, Adnan</creator><creator>Afzal, Adeel</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-8383-2627</orcidid><orcidid>https://orcid.org/0000-0002-6528-7300</orcidid><orcidid>https://orcid.org/0009-0008-7343-2193</orcidid></search><sort><creationdate>202310</creationdate><title>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</title><author>Saddique, Zohaib ; Siddique, Tazeen ; Shehzadi, Arooj ; Ul-Ain, Qurat ; Ali, Asghar ; Iqbal, Naseer ; Mujahid, Adnan ; Afzal, Adeel</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2023</creationdate><topic>Creatinine</topic><topic>Diagnostics</topic><topic>Electrochemical sensors</topic><topic>Nanocrystals</topic><topic>Point-of-care</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Saddique, Zohaib</creatorcontrib><creatorcontrib>Siddique, Tazeen</creatorcontrib><creatorcontrib>Shehzadi, Arooj</creatorcontrib><creatorcontrib>Ul-Ain, Qurat</creatorcontrib><creatorcontrib>Ali, Asghar</creatorcontrib><creatorcontrib>Iqbal, Naseer</creatorcontrib><creatorcontrib>Mujahid, Adnan</creatorcontrib><creatorcontrib>Afzal, Adeel</creatorcontrib><collection>CrossRef</collection><jtitle>Composites communications</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Saddique, Zohaib</au><au>Siddique, Tazeen</au><au>Shehzadi, Arooj</au><au>Ul-Ain, Qurat</au><au>Ali, Asghar</au><au>Iqbal, Naseer</au><au>Mujahid, Adnan</au><au>Afzal, Adeel</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics</atitle><jtitle>Composites communications</jtitle><date>2023-10</date><risdate>2023</risdate><volume>42</volume><spage>101673</spage><pages>101673-</pages><artnum>101673</artnum><issn>2452-2139</issn><eissn>2452-2139</eissn><abstract>Early diagnosis and monitoring of chronic diseases could alleviate the suffering of vulnerable people and prevent loss of lives, which largely depends on the availability of affordable and deliverable, yet sensitive analytical tools. We present a study aimed at optimizing the sensitivity of creatinine-imprinted polymers for disposable electrochemical sensors. For this purpose, various amounts of transition metal oxides with a layered structure, i.e., MoO3 (molybdite), V2O5 (shcherbinaite), and MoO3:V2O5 (schlegelite) nanocrystals, are embedded into a molecularly imprinted poly(methacrylic acid-co-ethylene glycol dimethacrylate) (MIP) to create composite receptor layers on the surface of disposable, screen-printed Au electrodes. Cyclic voltammetry (CV) measurements demonstrate that these oxides remarkably improve the sensitivity of MIP toward creatinine, a key biomarker for renal malfunction. Compared to pure MIP, the sensitivity of MIP/MoO3, MIP/V2O5, and MIP/MoO3:V2O5 is enhanced by 113%, 121%, and 319%, respectively; thereby realizing the goal of developing highly sensitive and cost-effective electrochemical diagnostics for the chronic kidney diseases. Also, the MIP/MoO3:V2O5 sensor exhibits very low detection limits (90 nM), fast response times (<1 min), and a linear detection range (5–30 μM) corresponding to the actual salivary concentration. Hence, these nanocrystallite-embedded electrochemical sensors have great potential for the diagnosis and monitoring of renal function.
[Display omitted]
•Unveiling several electrochemical creatinine sensors with a molecularly imprinted polymer.•Harnessing the power of molybdite, shcherbinaite, and new schlegelite nanocrystals.•Amplifying the sensitivity by 319% with super-sensitive MoO3–V2O5 schlegelite nanocrystals.•Delving into the realm of sub-100 nM detection limits with MIP/MoO3–V2O5 composites.•Realizing highly sensitive, smartphone-ready, portable, and user-friendly creatinine sensing.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.coco.2023.101673</doi><orcidid>https://orcid.org/0000-0001-8383-2627</orcidid><orcidid>https://orcid.org/0000-0002-6528-7300</orcidid><orcidid>https://orcid.org/0009-0008-7343-2193</orcidid></addata></record> |
fulltext | fulltext |
identifier | ISSN: 2452-2139 |
ispartof | Composites communications, 2023-10, Vol.42, p.101673, Article 101673 |
issn | 2452-2139 2452-2139 |
language | eng |
recordid | cdi_crossref_primary_10_1016_j_coco_2023_101673 |
source | ScienceDirect Freedom Collection |
subjects | Creatinine Diagnostics Electrochemical sensors Nanocrystals Point-of-care |
title | Tuning sensitivity of creatinine-imprinted polymers with new super-sensitive schlegelite nanocrystals for disposable electrochemical CKD diagnostics |
url | http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-02-03T01%3A18%3A12IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Tuning%20sensitivity%20of%20creatinine-imprinted%20polymers%20with%20new%20super-sensitive%20schlegelite%20nanocrystals%20for%20disposable%20electrochemical%20CKD%20diagnostics&rft.jtitle=Composites%20communications&rft.au=Saddique,%20Zohaib&rft.date=2023-10&rft.volume=42&rft.spage=101673&rft.pages=101673-&rft.artnum=101673&rft.issn=2452-2139&rft.eissn=2452-2139&rft_id=info:doi/10.1016/j.coco.2023.101673&rft_dat=%3Celsevier_cross%3ES245221392300181X%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c300t-576f11dac2a10afae11c21287330ebbbd312fd4e0b3d94a6cb8bc78c7cd2b0e13%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true |