Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures

•Accelerated corrosion tests on headed stud shear connectors in cracked concrete were conducted.•3D morphologies of corroded headed studs were first precisely measured.•Cracks in concrete slabs made the concentrated corrosion in the stud head more severe.•Length of the chloride transport path signif...

Full description

Saved in:
Bibliographic Details
Published in:Construction & building materials 2021-07, Vol.293, p.123440, Article 123440
Main Authors: Xu, Xiaoqing, He, Dongyang, Zeng, Shanwen, He, Wei, Tan, Hongmei, Yu, Zhiwei
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
cited_by cdi_FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3
cites cdi_FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3
container_end_page
container_issue
container_start_page 123440
container_title Construction & building materials
container_volume 293
creator Xu, Xiaoqing
He, Dongyang
Zeng, Shanwen
He, Wei
Tan, Hongmei
Yu, Zhiwei
description •Accelerated corrosion tests on headed stud shear connectors in cracked concrete were conducted.•3D morphologies of corroded headed studs were first precisely measured.•Cracks in concrete slabs made the concentrated corrosion in the stud head more severe.•Length of the chloride transport path significantly affects the stud corrosion in cracked concrete. Corrosion of headed studs leads to the degradation of mechanical properties of shear connectors and thus decreases the durability of steel and concrete composite structures. The effect of concrete cracks on stud corrosion was investigated in this study. Accelerated corrosion tests on headed stud shear connectors and numerical simulation on chloride migration were presented. 3D corrosion morphologies of headed studs in concrete slabs with different concrete cover thicknesses and crack widths and depths were precisely measured by using an optical surface measurement technique. The results show that there was highly localized corrosion in the stud head, and cracks had significant effect on the corrosion distribution. Then, after finite element models for chloride migration were verified by experimental results, a parametric study was carried out. It was found that in concrete slab with higher crack depth, chloride concentration around the headed stud increased more rapidly, while the crack width had slight effect on the distribution of chloride concentration. Moreover, the length of the chloride transport path was found to be a significant parameter that affect the stud corrosion.
doi_str_mv 10.1016/j.conbuildmat.2021.123440
format article
fullrecord <record><control><sourceid>elsevier_cross</sourceid><recordid>TN_cdi_crossref_primary_10_1016_j_conbuildmat_2021_123440</recordid><sourceformat>XML</sourceformat><sourcesystem>PC</sourcesystem><els_id>S0950061821012009</els_id><sourcerecordid>S0950061821012009</sourcerecordid><originalsourceid>FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3</originalsourceid><addsrcrecordid>eNqNkM1KAzEUhYMoWKvvEB9gxptkknSWUuoPFNzoOswkNzS1nSlJRvDtTamLLru658A5h8tHyCODmgFTT9vajkM_hZ3bd7nmwFnNuGgauCIzttBtBZKrazKDVkIFii1uyV1KWwBQXPEZwZX3aDMdPS1DNmJGamNnvxMdB5o3xY0xjikUVzIb7Bw6mvLkEg1DEYg72g3urD3uDyVfVMpxsnmKmO7Jje92CR_-75x8vaw-l2_V-uP1ffm8rqzgLFfMS68UB6GZ1GAX2PdcgETk2nkNSnVaovRtAyh8U7xCJZx0CoRvte_FnLSnXVteThG9OcSw7-KvYWCOvMzWnPEyR17mxKt0l6culgd_AkaTbMDBoguxEDJuDBes_AGlentO</addsrcrecordid><sourcetype>Aggregation Database</sourcetype><iscdi>true</iscdi><recordtype>article</recordtype></control><display><type>article</type><title>Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures</title><source>ScienceDirect Journals</source><creator>Xu, Xiaoqing ; He, Dongyang ; Zeng, Shanwen ; He, Wei ; Tan, Hongmei ; Yu, Zhiwei</creator><creatorcontrib>Xu, Xiaoqing ; He, Dongyang ; Zeng, Shanwen ; He, Wei ; Tan, Hongmei ; Yu, Zhiwei</creatorcontrib><description>•Accelerated corrosion tests on headed stud shear connectors in cracked concrete were conducted.•3D morphologies of corroded headed studs were first precisely measured.•Cracks in concrete slabs made the concentrated corrosion in the stud head more severe.•Length of the chloride transport path significantly affects the stud corrosion in cracked concrete. Corrosion of headed studs leads to the degradation of mechanical properties of shear connectors and thus decreases the durability of steel and concrete composite structures. The effect of concrete cracks on stud corrosion was investigated in this study. Accelerated corrosion tests on headed stud shear connectors and numerical simulation on chloride migration were presented. 3D corrosion morphologies of headed studs in concrete slabs with different concrete cover thicknesses and crack widths and depths were precisely measured by using an optical surface measurement technique. The results show that there was highly localized corrosion in the stud head, and cracks had significant effect on the corrosion distribution. Then, after finite element models for chloride migration were verified by experimental results, a parametric study was carried out. It was found that in concrete slab with higher crack depth, chloride concentration around the headed stud increased more rapidly, while the crack width had slight effect on the distribution of chloride concentration. Moreover, the length of the chloride transport path was found to be a significant parameter that affect the stud corrosion.</description><identifier>ISSN: 0950-0618</identifier><identifier>EISSN: 1879-0526</identifier><identifier>DOI: 10.1016/j.conbuildmat.2021.123440</identifier><language>eng</language><publisher>Elsevier Ltd</publisher><subject>Chloride ; Corrosion ; Crack ; Diffusion ; Electric field ; Headed stud</subject><ispartof>Construction &amp; building materials, 2021-07, Vol.293, p.123440, Article 123440</ispartof><rights>2021 Elsevier Ltd</rights><lds50>peer_reviewed</lds50><woscitedreferencessubscribed>false</woscitedreferencessubscribed><citedby>FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3</citedby><cites>FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3</cites><orcidid>0000-0001-7550-0120 ; 0000-0002-6288-4089</orcidid></display><links><openurl>$$Topenurl_article</openurl><openurlfulltext>$$Topenurlfull_article</openurlfulltext><thumbnail>$$Tsyndetics_thumb_exl</thumbnail><link.rule.ids>314,780,784,27924,27925</link.rule.ids></links><search><creatorcontrib>Xu, Xiaoqing</creatorcontrib><creatorcontrib>He, Dongyang</creatorcontrib><creatorcontrib>Zeng, Shanwen</creatorcontrib><creatorcontrib>He, Wei</creatorcontrib><creatorcontrib>Tan, Hongmei</creatorcontrib><creatorcontrib>Yu, Zhiwei</creatorcontrib><title>Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures</title><title>Construction &amp; building materials</title><description>•Accelerated corrosion tests on headed stud shear connectors in cracked concrete were conducted.•3D morphologies of corroded headed studs were first precisely measured.•Cracks in concrete slabs made the concentrated corrosion in the stud head more severe.•Length of the chloride transport path significantly affects the stud corrosion in cracked concrete. Corrosion of headed studs leads to the degradation of mechanical properties of shear connectors and thus decreases the durability of steel and concrete composite structures. The effect of concrete cracks on stud corrosion was investigated in this study. Accelerated corrosion tests on headed stud shear connectors and numerical simulation on chloride migration were presented. 3D corrosion morphologies of headed studs in concrete slabs with different concrete cover thicknesses and crack widths and depths were precisely measured by using an optical surface measurement technique. The results show that there was highly localized corrosion in the stud head, and cracks had significant effect on the corrosion distribution. Then, after finite element models for chloride migration were verified by experimental results, a parametric study was carried out. It was found that in concrete slab with higher crack depth, chloride concentration around the headed stud increased more rapidly, while the crack width had slight effect on the distribution of chloride concentration. Moreover, the length of the chloride transport path was found to be a significant parameter that affect the stud corrosion.</description><subject>Chloride</subject><subject>Corrosion</subject><subject>Crack</subject><subject>Diffusion</subject><subject>Electric field</subject><subject>Headed stud</subject><issn>0950-0618</issn><issn>1879-0526</issn><fulltext>true</fulltext><rsrctype>article</rsrctype><creationdate>2021</creationdate><recordtype>article</recordtype><recordid>eNqNkM1KAzEUhYMoWKvvEB9gxptkknSWUuoPFNzoOswkNzS1nSlJRvDtTamLLru658A5h8tHyCODmgFTT9vajkM_hZ3bd7nmwFnNuGgauCIzttBtBZKrazKDVkIFii1uyV1KWwBQXPEZwZX3aDMdPS1DNmJGamNnvxMdB5o3xY0xjikUVzIb7Bw6mvLkEg1DEYg72g3urD3uDyVfVMpxsnmKmO7Jje92CR_-75x8vaw-l2_V-uP1ffm8rqzgLFfMS68UB6GZ1GAX2PdcgETk2nkNSnVaovRtAyh8U7xCJZx0CoRvte_FnLSnXVteThG9OcSw7-KvYWCOvMzWnPEyR17mxKt0l6culgd_AkaTbMDBoguxEDJuDBes_AGlentO</recordid><startdate>20210726</startdate><enddate>20210726</enddate><creator>Xu, Xiaoqing</creator><creator>He, Dongyang</creator><creator>Zeng, Shanwen</creator><creator>He, Wei</creator><creator>Tan, Hongmei</creator><creator>Yu, Zhiwei</creator><general>Elsevier Ltd</general><scope>AAYXX</scope><scope>CITATION</scope><orcidid>https://orcid.org/0000-0001-7550-0120</orcidid><orcidid>https://orcid.org/0000-0002-6288-4089</orcidid></search><sort><creationdate>20210726</creationdate><title>Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures</title><author>Xu, Xiaoqing ; He, Dongyang ; Zeng, Shanwen ; He, Wei ; Tan, Hongmei ; Yu, Zhiwei</author></sort><facets><frbrtype>5</frbrtype><frbrgroupid>cdi_FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3</frbrgroupid><rsrctype>articles</rsrctype><prefilter>articles</prefilter><language>eng</language><creationdate>2021</creationdate><topic>Chloride</topic><topic>Corrosion</topic><topic>Crack</topic><topic>Diffusion</topic><topic>Electric field</topic><topic>Headed stud</topic><toplevel>peer_reviewed</toplevel><toplevel>online_resources</toplevel><creatorcontrib>Xu, Xiaoqing</creatorcontrib><creatorcontrib>He, Dongyang</creatorcontrib><creatorcontrib>Zeng, Shanwen</creatorcontrib><creatorcontrib>He, Wei</creatorcontrib><creatorcontrib>Tan, Hongmei</creatorcontrib><creatorcontrib>Yu, Zhiwei</creatorcontrib><collection>CrossRef</collection><jtitle>Construction &amp; building materials</jtitle></facets><delivery><delcategory>Remote Search Resource</delcategory><fulltext>fulltext</fulltext></delivery><addata><au>Xu, Xiaoqing</au><au>He, Dongyang</au><au>Zeng, Shanwen</au><au>He, Wei</au><au>Tan, Hongmei</au><au>Yu, Zhiwei</au><format>journal</format><genre>article</genre><ristype>JOUR</ristype><atitle>Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures</atitle><jtitle>Construction &amp; building materials</jtitle><date>2021-07-26</date><risdate>2021</risdate><volume>293</volume><spage>123440</spage><pages>123440-</pages><artnum>123440</artnum><issn>0950-0618</issn><eissn>1879-0526</eissn><abstract>•Accelerated corrosion tests on headed stud shear connectors in cracked concrete were conducted.•3D morphologies of corroded headed studs were first precisely measured.•Cracks in concrete slabs made the concentrated corrosion in the stud head more severe.•Length of the chloride transport path significantly affects the stud corrosion in cracked concrete. Corrosion of headed studs leads to the degradation of mechanical properties of shear connectors and thus decreases the durability of steel and concrete composite structures. The effect of concrete cracks on stud corrosion was investigated in this study. Accelerated corrosion tests on headed stud shear connectors and numerical simulation on chloride migration were presented. 3D corrosion morphologies of headed studs in concrete slabs with different concrete cover thicknesses and crack widths and depths were precisely measured by using an optical surface measurement technique. The results show that there was highly localized corrosion in the stud head, and cracks had significant effect on the corrosion distribution. Then, after finite element models for chloride migration were verified by experimental results, a parametric study was carried out. It was found that in concrete slab with higher crack depth, chloride concentration around the headed stud increased more rapidly, while the crack width had slight effect on the distribution of chloride concentration. Moreover, the length of the chloride transport path was found to be a significant parameter that affect the stud corrosion.</abstract><pub>Elsevier Ltd</pub><doi>10.1016/j.conbuildmat.2021.123440</doi><orcidid>https://orcid.org/0000-0001-7550-0120</orcidid><orcidid>https://orcid.org/0000-0002-6288-4089</orcidid></addata></record>
fulltext fulltext
identifier ISSN: 0950-0618
ispartof Construction & building materials, 2021-07, Vol.293, p.123440, Article 123440
issn 0950-0618
1879-0526
language eng
recordid cdi_crossref_primary_10_1016_j_conbuildmat_2021_123440
source ScienceDirect Journals
subjects Chloride
Corrosion
Crack
Diffusion
Electric field
Headed stud
title Effect of concrete cracks on the corrosion of headed studs in steel and concrete composite structures
url http://sfxeu10.hosted.exlibrisgroup.com/loughborough?ctx_ver=Z39.88-2004&ctx_enc=info:ofi/enc:UTF-8&ctx_tim=2025-01-07T23%3A35%3A30IST&url_ver=Z39.88-2004&url_ctx_fmt=infofi/fmt:kev:mtx:ctx&rfr_id=info:sid/primo.exlibrisgroup.com:primo3-Article-elsevier_cross&rft_val_fmt=info:ofi/fmt:kev:mtx:journal&rft.genre=article&rft.atitle=Effect%20of%20concrete%20cracks%20on%20the%20corrosion%20of%20headed%20studs%20in%20steel%20and%20concrete%20composite%20structures&rft.jtitle=Construction%20&%20building%20materials&rft.au=Xu,%20Xiaoqing&rft.date=2021-07-26&rft.volume=293&rft.spage=123440&rft.pages=123440-&rft.artnum=123440&rft.issn=0950-0618&rft.eissn=1879-0526&rft_id=info:doi/10.1016/j.conbuildmat.2021.123440&rft_dat=%3Celsevier_cross%3ES0950061821012009%3C/elsevier_cross%3E%3Cgrp_id%3Ecdi_FETCH-LOGICAL-c321t-1f5f6620371570c8ebb2305ee27df7066a75e5f940e3f40666e63d5d603f97fb3%3C/grp_id%3E%3Coa%3E%3C/oa%3E%3Curl%3E%3C/url%3E&rft_id=info:oai/&rft_id=info:pmid/&rfr_iscdi=true