Loading…

The Impact of Humidification Temperature on a 1 kW Proton Exchange Membrane Fuel Cell Stack

The importance of water management in proton exchange membrane fuel cells is discussed in this paper. First part of research is dedicated to the characterization of a water-cooled 1kW PEMFC fuel cell stack at different operating conditions with calculation of net electric and thermal efficiencies. I...

Full description

Saved in:
Bibliographic Details
Published in:Energy procedia 2017-01, Vol.142, p.1661-1667
Main Authors: Sveshnikova, Aleksandra, Marcoberardino, Gioele Di, Pirrone, Claudio, Bischi, Aldo, Valenti, Gianluca, Ustinov, Alexander, Campanari, Stefano
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:The importance of water management in proton exchange membrane fuel cells is discussed in this paper. First part of research is dedicated to the characterization of a water-cooled 1kW PEMFC fuel cell stack at different operating conditions with calculation of net electric and thermal efficiencies. In the second part, the influence of inlet air humidification temperature at various loads and operational conditions was experimentally found. It was observed that humidification temperature in the air saturator has a strong impact on cell performance and this impact is growing with current density. Increase in humidification temperature by 8°C at 200mA/cm2 raised cell voltage only by 0.01V, while at 500mA/cm2 the same change led to 0.04V growth. Additionally, the effect of change of air stoichiometry on this relationship is studied. Increased air stoichiometry led to a maximum growth of the slope angle by 68% at 500mA/cm2.
ISSN:1876-6102
1876-6102
DOI:10.1016/j.egypro.2017.12.546