Loading…
Accurate AC/DC voltage measurements using electrostatic comparator
The electrostatic AC-DC voltage comparator for precise voltage measurement in voltage range of 100–1000 V and frequency range of 20–100,000 Hz was designed. The equality of AC and DC voltages transforms into horizontal positioning of the beam, which is registered by two photoelectric transducers. DC...
Saved in:
Published in: | Journal of electrostatics 2016-08, Vol.82, p.17-21 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | The electrostatic AC-DC voltage comparator for precise voltage measurement in voltage range of 100–1000 V and frequency range of 20–100,000 Hz was designed. The equality of AC and DC voltages transforms into horizontal positioning of the beam, which is registered by two photoelectric transducers. DC voltage was measured by voltage divider, standard cell and low-voltage comparator. The construction, main characteristics, and sources of errors are described. The comparison error has been determined as having the value of 0.003% at the voltage of 100 V and the value of 0.0009% at the voltage of 1000 V.
•AC-DC voltage comparator compares the moments generated by applied AC and DC voltages.•The beam AC-DC voltage comparator is mounted by a system of eight tout bands.•The equality of AC and DC voltages is determined by the horizontal position of the beam.•The error of designed electrostatic comparator is in the range of 0.003–0.0009%. |
---|---|
ISSN: | 0304-3886 1873-5738 |
DOI: | 10.1016/j.elstat.2016.04.005 |