Thermal modeling of a greenhouse with an integrated earth to air heat exchanger: an experimental validation

A simplified analytical model is developed to study the year round effectiveness of a recirculation type earth air heat exchanger coupled with a greenhouse located in IIT Delhi, India. The performance of the system was evaluated in terms of thermal load leveling and coefficient of performance. Calcu...

Full description

Saved in:
Bibliographic Details
Published in:Energy and buildings 2004-03, Vol.36 (3), p.219-227
Main Authors: Ghosal, M.K., Tiwari, G.N., Srivastava, N.S.L.
Format: Article
Language:English
Subjects:
Citations: Items that this one cites
Items that cite this one
Online Access:Get full text
Tags: Add Tag
No Tags, Be the first to tag this record!
Description
Summary:A simplified analytical model is developed to study the year round effectiveness of a recirculation type earth air heat exchanger coupled with a greenhouse located in IIT Delhi, India. The performance of the system was evaluated in terms of thermal load leveling and coefficient of performance. Calculations were done for typical winter and summer day in year 2002. Temperatures of greenhouse air were found to be on an average 6–7 °C more in winter and 3–4 °C less in summer than the same greenhouse when operating without earth air heat exchanger. Predicted and measured values of greenhouse air temperatures exhibited fair agreement.