Progressive collapse of a steel structure under expected snow loads
•Main reasons for the collapse of a steel structure of a factory were investigated.•Buckling analyses were carried out to prove the field observations.•Progressive collapse mechanism of the structure was determined.•Lateral torsional buckling behavior is vital importance of the steel connections’ st...
Saved in:
Published in: | Engineering failure analysis 2021-07, Vol.125, p.105378, Article 105378 |
---|---|
Main Authors: | , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •Main reasons for the collapse of a steel structure of a factory were investigated.•Buckling analyses were carried out to prove the field observations.•Progressive collapse mechanism of the structure was determined.•Lateral torsional buckling behavior is vital importance of the steel connections’ stability.•Analytical results agreed well with the field investigations.
The structural design process has many vital roles in preventing the collapse of structures and should be conducted according to national obligatory standards. However; structural failures or even catastrophic collapses based on improper design, underestimated design loads, unexpected extreme loads, and improper erection are reported worldwide on large-span structures. A steel structure of the factory partially collapsed under expected snow loads in the western part of Turkey was investigated in this study. The possible reasons for the collapse of the system were examined by visual inspections and analytical results. The load-carrying capacities of the main girders and purlins were determined using the buckling analyses of the structural member. The nonlinear geometric analysis of the entire steel structural system was defined to evaluate the vertical load-carrying capacity of the main girder. The progressive collapse mechanism of the system was determined. The obtained results indicate that the snow load is not the main reason for the collapse and mistakes in the project design, constructional defects and inadequate capacity of structural elements are the primary reasons behind the collapse. |
---|---|