Loading…
Low-cycle compression-compression fatigue behavior of MEX-printed PLA parts
•LCF compression-compression behavior of MEX-printed PLA parts is investigated.•The quasi-static compression behavior of 3D printed parts is similar to cellular materials.•The printed parts have a high dimensional accuracy, with maximum relative errors below 0.04 %.•The lifetime part of the unified...
Saved in:
Published in: | Engineering failure analysis 2024-07, Vol.161, p.108335, Article 108335 |
---|---|
Main Authors: | , , , |
Format: | Article |
Language: | English |
Subjects: | |
Citations: | Items that this one cites Items that cite this one |
Online Access: | Get full text |
Tags: |
Add Tag
No Tags, Be the first to tag this record!
|
Summary: | •LCF compression-compression behavior of MEX-printed PLA parts is investigated.•The quasi-static compression behavior of 3D printed parts is similar to cellular materials.•The printed parts have a high dimensional accuracy, with maximum relative errors below 0.04 %.•The lifetime part of the unified S-N (or Wöhler) diagram was drawn with its 95 % level confidence bands.•During the LCF tests, the formation of a shear band was the main collapse mechanism of the 3D-printed samples.
Due to cyclic loads, additively manufactured (AM) parts can collapse at lower stress values than the strength corresponding to static loads. To date, there is limited research on the fatigue life of AM polymers. The present work investigates the fatigue behavior of material extrusion (MEX) printed Polylactic acid (PLA) parts. In this regard, the low-cycle fatigue (LCF) domain was studied and a compression-compression fatigue test setup was adopted. Initially, before the experimental tests, the MEX-printed samples were subjected to physical assessments. The printed fatigue samples presented a high accuracy with dimensional relative errors below 0.04%, while 6.66% was noted as their mass relative error. Subsequently, quasi-static and cyclic tests were performed in order to determine the mechanical behavior of the AM parts, with special focus on the low-cycle domain of the S-N (or Wöhler) curve. The quasi-static compression behavior of the PLA samples is typical of cellular materials, the samples highlighting a shear band as a failure mechanism. Five load levels were used to plot the low-cycle domain of the S-N (or Wöhler) curve with its 95% level confidence bands. The tests were performed in force-controlled mode with the stress asymmetry ratio R = 0.1 and at the test frequency of f = 10 Hz. An exponential relationship was also found between the strain at break and the number of cycles until failure. The failure of the samples in fatigue load occurred suddenly. |
---|---|
ISSN: | 1350-6307 |
DOI: | 10.1016/j.engfailanal.2024.108335 |